| Literature DB >> 26377393 |
Agata Janecka-Placek1, Grażyna Lisowska2, Andrzej Paradysz3, Hanna Misiołek1.
Abstract
BACKGROUND: The aim of the study was to examine the effect of spinal anesthesia on the function of cochlear outer hair cells (OHCs), determined by means of objective distortion product otoacoustic emissions (DPOAE) testing. To the best of our knowledge, our study was the second OAE-based analysis of cochlear function during spinal anesthesia, and the only experiment including such a large group of patients.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26377393 PMCID: PMC4578649 DOI: 10.12659/MSM.893718
Source DB: PubMed Journal: Med Sci Monit ISSN: 1234-1010
Basic characteristics of the study participants (n=20).
| Parameter | Mean ±SD/n (%) |
|---|---|
| Age (years) | 27.2±6.6 |
| Men | 18 (90%) |
| Women | 2 (10%) |
| Body height (cm) | 177±7.6 |
| Body weight (kg) | 79.6±15.9 |
| ASA I | 20 (100%) |
| Tobacco smoking | 6 (30%) |
| Duration of the surgery (min) | 37.5±15.0 |
Hemodynamic parameters of the studied patients (arithmetic means of consecutive values recorded during the anesthesia).
| Parameter | Mean ±SD |
|---|---|
| Systolic blood pressure (mm Hg) | 131.3±14.9 |
| Diastolic blood pressure (mm Hg) | 71.8±11.5 |
| Mean blood pressure (mm Hg) | 95.5±11.6 |
| Heart rate (beats/min) | 70.4±10.2 |
| Saturation (%) | 99.1±0.8 |
Results of pure tone audiometry: PTA-1 (mean threshold for 250 Hz, 500 Hz, 1000 Hz), PTA-2 (mean threshold for 1 kHz, 2 kHz, 4 kHz), and PTA-3 (mean threshold for 1 kHz, 2 kHz, 4 kHz, 6 kHz)*.
| Group | PTA-1 (dB HL) | PTA-2 (dB HL) | PTA-3 (dB HL) |
|---|---|---|---|
| Subjects 18–45 years | 7.3±3.9 | 6.3±4.6 | 7.05±5.1 |
According to the methodologically accepted qualification criteria, all subjects had average hearing threshold level across the octave frequencies from 0.25 to 4.0 kHz (less than 30 dB HL).
Figure 1Levels of DPOAEs and background noise documented prior to (recording 0, circles) and immediately after the anesthesia (recording 1, squares). Significant differences at * p≤0.05, ** p≤0.01, and *** p≤0.001.
Figure 2Levels of DPOAEs and background noise documented prior to (recording 0, circles) and on the postoperative day 2 (recording 2, squares). Significant differences at * p≤0.05, ** p≤0.01, and *** p≤0.001.