Simulating cardiac ultrasound image based on MR diffusion tensor imaging.

Xulei Qin1, Silun Wang2, Ming Shen3, Guolan Lu4, Xiaodong Zhang2, Mary B Wagner3, Baowei Fei5.   

Abstract

PURPOSE: Cardiac ultrasound simulation can have important applications in the design of ultrasound systems, understanding the interaction effect between ultrasound and tissue and setting the ground truth for validating quantification methods. Current ultrasound simulation methods fail to simulate the myocardial intensity anisotropies. New simulation methods are needed in order to simulate realistic ultrasound images of the heart.
METHODS: The proposed cardiac ultrasound image simulation method is based on diffusion tensor imaging (DTI) data of the heart. The method utilizes both the cardiac geometry and the fiber orientation information to simulate the anisotropic intensities in B-mode ultrasound images. Before the simulation procedure, the geometry and fiber orientations of the heart are obtained from high-resolution structural MRI and DTI data, respectively. The simulation includes two important steps. First, the backscatter coefficients of the point scatterers inside the myocardium are processed according to the fiber orientations using an anisotropic model. Second, the cardiac ultrasound images are simulated with anisotropic myocardial intensities. The proposed method was also compared with two other nonanisotropic intensity methods using 50 B-mode ultrasound image volumes of five different rat hearts. The simulated images were also compared with the ultrasound images of a diseased rat heart in vivo. A new segmental evaluation method is proposed to validate the simulation results. The average relative errors (AREs) of five parameters, i.e., mean intensity, Rayleigh distribution parameter σ, and first, second, and third quartiles, were utilized as the evaluation metrics. The simulated images were quantitatively compared with real ultrasound images in both ex vivo and in vivo experiments.
RESULTS: The proposed ultrasound image simulation method can realistically simulate cardiac ultrasound images of the heart using high-resolution MR-DTI data. The AREs of their proposed method are 19% for the mean intensity, 17.7% for the scale parameter of Rayleigh distribution, 36.8% for the first quartile of the image intensities, 25.2% for the second quartile, and 19.9% for the third quartile. In contrast, the errors of the other two methods are generally five times more than those of their proposed method.
CONCLUSIONS: The proposed simulation method uses MR-DTI data and realistically generates cardiac ultrasound images with anisotropic intensities inside the myocardium. The ultrasound simulation method could provide a tool for many potential research and clinical applications in cardiac ultrasound imaging.

Entities:  

Mesh:

Year:  2015        PMID: 26328966      PMCID: PMC4537486          DOI: 10.1118/1.4927788

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Segmentation of 3D radio frequency echocardiography using a spatio-temporal predictor.

Authors:  P C Pearlman; H D Tagare; B A Lin; A J Sinusas; J S Duncan
Journal:  Med Image Anal       Date:  2011-10-14       Impact factor: 8.545

2.  3D ultrasound image segmentation using wavelet support vector machines.

Authors:  Hamed Akbari; Baowei Fei
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

3.  Speckle reducing anisotropic diffusion.

Authors:  Yongjian Yu; Scott T Acton
Journal:  IEEE Trans Image Process       Date:  2002       Impact factor: 10.856

4.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  3-D speckle tracking for assessment of regional left ventricular function.

Authors:  Jonas Crosby; Brage H Amundsen; Torbjørn Hergum; Espen W Remme; Stian Langeland; Hans Torp
Journal:  Ultrasound Med Biol       Date:  2008-12-04       Impact factor: 2.998

6.  The effect of including myocardial anisotropy in simulated ultrasound images of the heart.

Authors:  Jonas Crosby; Torbjørn Hergum; Espen W Remme; Hans Torp
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-02       Impact factor: 2.725

7.  Generation of synthetic but visually realistic time series of cardiac images combining a biophysical model and clinical images.

Authors:  Adityo Prakosa; Maxime Sermesant; Hervé Delingette; Stéphanie Marchesseau; Eric Saloux; Pascal Allain; Nicolas Villain; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2012-09-21       Impact factor: 10.048

8.  Measuring body-cover vibration of vocal folds based on high frame rate ultrasonic imaging and high-speed video.

Authors:  Xulei Qin; Liang Wu; Hujie Jiang; Shanshan Tang; Supin Wang; Mingxi Wan
Journal:  IEEE Trans Biomed Eng       Date:  2011-05-19       Impact factor: 4.538

9.  A model of ultrasound backscatter for the assessment of myocardial tissue structure and architecture.

Authors:  M F Santarelli; L Landini
Journal:  IEEE Trans Biomed Eng       Date:  1996-09       Impact factor: 4.538

10.  Fiber orientation in the canine left ventricle during diastole and systole.

Authors:  D D Streeter; H M Spotnitz; D P Patel; J Ross; E H Sonnenblick
Journal:  Circ Res       Date:  1969-03       Impact factor: 17.367

View more
  4 in total

1.  Imaging technologies for cardiac fiber and heart failure: a review.

Authors:  Shana R Watson; James D Dormer; Baowei Fei
Journal:  Heart Fail Rev       Date:  2018-03       Impact factor: 4.214

2.  GPU-Based Simulation of Echocardiography Volumes Using Quantitative Fiber-Angle-to-Backscatter Measurements.

Authors:  Megan Yociss; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-24

3.  Application and clinical significance of tissue ultrasound for assessment of right ventricular diastolic function in patients with coronary slow flow.

Authors:  Xuefang Zhu; Xiuping Xu; Zhen Wei; Zenghua Zhu
Journal:  Pak J Med Sci       Date:  2022 Mar-Apr       Impact factor: 2.340

4.  Adaptive anisotropic gaussian filtering to reduce acquisition time in cardiac diffusion tensor imaging.

Authors:  Ria Mazumder; Bradley D Clymer; Xiaokui Mo; Richard D White; Arunark Kolipaka
Journal:  Int J Cardiovasc Imaging       Date:  2016-02-02       Impact factor: 2.357

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.