Abstract
BACKGROUND: As a well-known, physical carcinogen, ambient X-ray pollution assessment would be of great importance in today's modern world. Accordingly, the present study was done to measure the exposure level of ambient X-ray at inspection gates of two airports in Iran. According to which, the X-ray was measured at different points of the inspection gates including closed and opened Curtain, as well as seating place of operators beside the X-ray inspection systems. The recorded data were then analyzed by "sign" and t-tests.Entities:
Keywords: Airport; Electromagnetic ionizing rays; Inspection gates; X-ray
Year: 2014 PMID: 24955243 PMCID: PMC4054912 DOI: 10.1186/2052-336X-12-88
Source DB: PubMed Journal: J Environ Health Sci Eng
Figure 1Position of measurement points at baggage x-ray machines.
Location of the X-ray machines as the sampling points
| A | South | 1 | M | West | 1 | W |
| B | South | 2 | M | West | 1 | M |
| C | South | 1 | W | West | 2 | M |
| D | South | 2 | W | East | 1 | M |
| E | North | 1 | M | East | 2 | M |
| F | North | 1 | W | East | 2 | W |
Ambient x-ray radiation results by devices (μsv.h)
| RAPISCAN | Men | 25 | 1.3 | 2 | 5 |
| Women | 25 | 1.2 | 1.1 | 1.9 | |
| HEIMANN | Men | 25 | 1.4 | 5.8 | 8.9 |
| Women | 25 | 1.4 | 1.1 | 1.2 | |
Figure 2Comparison of radiation doses released from the devices in Mehrabad and Imam Khomeini Airports.
Figure 3Comparison of radiation dose of measurement points surrounding the devices.