Literature DB >> 24950751

Prone-position acquisition of myocardial (123)I-metaiodobenzylguanidine (MIBG) SPECT reveals regional uptake similar to that found using (11)C-hydroxyephedrine PET/CT.

Keiichiro Yoshinaga1, Yuuki Tomiyama, Osamu Manabe, Katsuhiko Kasai, Chietsugu Katoh, Kenichi Magota, Eriko Suzuki, Ken-Ichi Nishijima, Yuji Kuge, Yoichi M Ito, Nagara Tamaki.   

Abstract

OBJECTIVES: (123)I-metaiodobenzylguanidine (MIBG) has been used to estimate cardiac sympathetic nervous innervation. Heterogeneous MIBG distribution is mainly associated with high physiological MIBG uptakes in the liver. We postulate that prone position acquisition might be especially effective for MIBG, providing for separation from high liver uptake similar to that provided by perfusion single-photon emission computed tomography (SPECT). We investigated whether prone-position acquisition improved MIBG image quality by comparing our results to those acquired using supine MIBG and high-quality (11)C-hydroxyephedrine (HED) positron emission tomography/computed tomography PET/CT.
METHODS: Ten male volunteers (body mass index (BMI) 22.7 ± 3.4) underwent prone and supine MIBG and HED PET. Relative regional tracer uptake was estimated in early MIBG and HED. Acquired images were divided into 17 segments and were grouped into 4 regions: anterior, inferior, septum, and lateral. For each patient, the inferior/anterior ratio was calculated.
RESULTS: The quality of images acquired using prone MIBG was better than that using supine MIBG (p < 0.05). Inferior and septum relative MIBG uptake was reduced in comparison with anterior or lateral MIBG uptake in the supine position (inferior vs. anterior: 69.0 ± 5.6 vs. 82.3 ± 4.6 %, p < 0.01; septum vs. lateral: 66.2 ± 5.1 vs. 81.9 ± 5.4 %, p < 0.01). Prone MIBG showed a significantly higher inferior/anterior uptake ratio in comparison with supine MIBG (n = 24, seg: 92.2 ± 7.2 vs. 83.6 ± 5.7 %, p < 0.05). However, intergroup differences in uptake ratio were demonstrated among prone and supine MIBG and HED. HED PET/CT still showed a higher uptake ratio in comparison with prone MIBG SPECT (103.9 ± 8.0 vs. 92.2 ± 7.2 %, p < 0.05).
CONCLUSION: Even in normal male subjects, standard supine MIBG imaging showed reduced inferior and septum uptake. Uptake with prone MIBG imaging showed a significant improvement over that with supine imaging and was closer to uptake for HED PET/CT. This improvement may be the result of preventing intense uptake by the liver. Prone data acquisition may be a viable alternative in evaluating regional abnormalities using MIBG SPECT in men.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24950751     DOI: 10.1007/s12149-014-0868-z

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  6 in total

1.  Predicting cardiac events using ventricular dyssynchrony in patients who received implantable cardioverter defibrillators: Are more treatment options required?

Authors:  Keiichiro Yoshinaga
Journal:  J Nucl Cardiol       Date:  2015-11-24       Impact factor: 5.952

Review 2.  Current status of nuclear cardiology in Japan: Ongoing efforts to improve clinical standards and to establish evidence.

Authors:  Keiichiro Yoshinaga; Nagara Tamaki
Journal:  J Nucl Cardiol       Date:  2015-04-22       Impact factor: 5.952

3.  Impact of obesity and acquisition protocol on (123)I-metaiodobenzylguanidine indexes of cardiac sympathetic innervation.

Authors:  Teresa Pellegrino; Valentina Piscopo; Antonio Boemio; Barbara Russo; Gianluca De Matteis; Sara Pellegrino; Sara Maria Delle Acque Giorgio; Manuela Amato; Mario Petretta; Alberto Cuocolo
Journal:  Quant Imaging Med Surg       Date:  2015-12

4.  Spatial Inhomogeneity of Cardiac Norepinephrine Transport Protein and Meta-[123I]Iodobenzylguanidine Uptake in Swine Myocardial Tissue.

Authors:  Claudia Kusmic; Assuero Giorgetti; Cristina Barsanti; Silvia Burchielli; Debora Petroni; Annette Kusch; Dario Genovesi; Luca Menichetti; Paolo Marzullo
Journal:  Mol Imaging Biol       Date:  2019-06       Impact factor: 3.488

5.  Early therapeutic effects of adaptive servo-ventilation on cardiac sympathetic nervous function in patients with heart failure evaluated using a combination of 11C-HED PET and 123I-MIBG SPECT.

Authors:  Yusuke Tokuda; Mamoru Sakakibara; Keiichiro Yoshinaga; Shiro Yamada; Kiwamu Kamiya; Naoya Asakawa; Takashi Yoshitani; Keiji Noguchi; Osamu Manabe; Nagara Tamaki; Hiroyuki Tsutsui
Journal:  J Nucl Cardiol       Date:  2017-11-27       Impact factor: 5.952

6.  Uniformity of cardiac 123I-MIBG uptake on SPECT images in older adults with normal cognition and patients with dementia.

Authors:  Gemma Roberts; Jim J Lloyd; Elizabeth Jefferson; Joseph P M Kane; Rory Durcan; Sarah Lawley; George S Petrides; Kim Howe; Iftikhar Haq; John T O'Brien; Alan J Thomas
Journal:  J Nucl Cardiol       Date:  2019-12-09       Impact factor: 5.952

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.