OBJECTIVE: To assure the accuracy and reliability of blood pressure measurement by non-invasive blood pressure monitor using Datascope Accutorr Plus™ (Paramus, NJ, USA) against mercury manometer, among adult male participants. METHOD: Eighty participants from a family physician's office at a teaching hospital were recruited. One hundred and sixty measurements of blood pressure were performed according to BHS technique protocol. STATISTICAL ANALYSIS: Descriptive analysis was done according to the AAMI and BHS protocol guidelines. The limits of agreement between the device and the standard were plotted using the method of Bland and Altman plot. RESULTS: The mean difference ± SD between the Datascope Acutorr Plus™ and observer was 2.7 ± 5.2 mm Hg and 1.5 ± 3.26 mm Hg for systolic and diastolic blood pressure, respectively. Datascope Acutorr Plus™ obtained A/A grading for both systolic and diastolic blood pressure. CONCLUSION: Datascope Accutorr Plus™ (Paramus, NJ, USA) satisfies BHS and AAMI validation protocols for both systolic and diastolic BP and may be recommended for everyday use for BP monitoring at home and in clinical use for adult population.
OBJECTIVE: To assure the accuracy and reliability of blood pressure measurement by non-invasive blood pressure monitor using Datascope Accutorr Plus™ (Paramus, NJ, USA) against mercury manometer, among adult male participants. METHOD: Eighty participants from a family physician's office at a teaching hospital were recruited. One hundred and sixty measurements of blood pressure were performed according to BHS technique protocol. STATISTICAL ANALYSIS: Descriptive analysis was done according to the AAMI and BHS protocol guidelines. The limits of agreement between the device and the standard were plotted using the method of Bland and Altman plot. RESULTS: The mean difference ± SD between the Datascope Acutorr Plus™ and observer was 2.7 ± 5.2 mm Hg and 1.5 ± 3.26 mm Hg for systolic and diastolic blood pressure, respectively. Datascope Acutorr Plus™ obtained A/A grading for both systolic and diastolic blood pressure. CONCLUSION: Datascope Accutorr Plus™ (Paramus, NJ, USA) satisfies BHS and AAMI validation protocols for both systolic and diastolic BP and may be recommended for everyday use for BP monitoring at home and in clinical use for adult population.
Entities:
Keywords:
AAMI; BHS; BP devices; Datascope Acutorr plus; Validation
Authors: Mohammed Al Ghobain; H Alhashemi; A Aljama; S Bin Salih; Z Assiri; A Alsomali; Gamal Mohamed Journal: Patient Prefer Adherence Date: 2016-08-01 Impact factor: 2.711
Authors: Laura Benschop; Sarah Schalekamp-Timmermans; Sara J C Schelling; Eric A P Steegers; Jeanine E Roeters van Lennep Journal: J Am Heart Assoc Date: 2019-07-23 Impact factor: 5.501
Authors: Maria C Adank; Zoe A Broere-Brown; Romy Gonçalves; M Kamran Ikram; Vincent W V Jaddoe; Eric A P Steegers; Sarah Schalekamp-Timmermans Journal: BMC Pregnancy Childbirth Date: 2020-05-29 Impact factor: 3.007
Authors: Sander Lamballais; Maria C Adank; Rowina F Hussainali; Sarah Schalekamp-Timmermans; Meike W Vernooij; Annemarie I Luik; Eric A P Steegers; Mohammad Arfan Ikram Journal: Eur J Epidemiol Date: 2020-12-16 Impact factor: 8.082
Authors: Eliane F E Wenstedt; Hessel Peters Sengers; S Matthijs Boekholdt; Kay-Tee Khaw; Nicholas J Wareham; Bert-Jan H van den Born; Liffert Vogt Journal: J Am Heart Assoc Date: 2022-06-22 Impact factor: 6.106
Authors: Laura Benschop; Sarah Schalekamp-Timmermans; Jeanine E Roeters van Lennep; Vincent W V Jaddoe; Eric A P Steegers; M Kamran Ikram Journal: J Am Heart Assoc Date: 2018-10-02 Impact factor: 5.501