Accuracy of the Dinamap 1846 XT automated blood pressure monitor.

E R Beaubien1, C M Card, S E Card, H J Biem, T W Wilson.   

Abstract

Accurate blood pressure (BP) measurement is important for the detection and treatment of hypertension. Despite widespread use of automated devices, there is limited published evidence for their reliability and accuracy. To determine the reliability and accuracy of the Dinamap 1846XT (Critikon Corporation, Tampa, FL, USA), a commonly used non-invasive oscillometric BP monitor The Dinamap was evaluated against the mercury manometer in 70 randomly selected adult hospitalised medical patients. Each individual underwent three sets of standardised BP measurement by automated method and three sets by mercury manometer by two independent observers. Reliability of BP measurement was assessed by repeated measures analysis. Dinamap accuracy was evaluated according to the American Association of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) guidelines. Most patients were either normotensive or had stage I hypertension. The Dinamap tended to overestimate lower diastolic BP, and displayed poor reliability (P < 0.05). despite meeting aami guidelines, only 59% of systolic and 56% of diastolic dinamap readings were within 5 mm hg of the mercury manometer and 84% of systolic and 80% of diastolic readings were within 10 mm hg (bhs grade c). systolic and diastolic accuracy were worse with pressures >160/90 mm Hg (grade D) although these measures were based on a smaller sample of subjects. In conclusion the Dinamap yields inaccurate estimates of both systolic and diastolic BP even under standardised, and thus optimal conditions. This inaccuracy is exaggerated at higher BP (>160/90 mm Hg), although the number of measurements at higher pressures was small. We recommend that this device not be used when accurate BP measurement is needed for therapeutic decision-making.

Entities:  

Mesh:

Year:  2002        PMID: 12214262     DOI: 10.1038/sj.jhh.1001463

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  7 in total

1.  Reductions in resting blood pressure after 4 weeks of isometric exercise training.

Authors:  Gavin R Devereux; Jonathan D Wiles; Ian L Swaine
Journal:  Eur J Appl Physiol       Date:  2010-02-26       Impact factor: 3.078

2.  Validation of Datascope Accutorr Plus™ using British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) protocol guidelines.

Authors:  Rajab Ali Khawaja; Riaz Qureshi; Abdul Hay Mansure; Mohammad Emran Yahya
Journal:  J Saudi Heart Assoc       Date:  2010-03-10

3.  Model-based oscillometric blood pressure measurement: preliminary validation in humans.

Authors:  Jiankun Liu; Hao-min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

4.  Bramwell-Hill modeling for local aortic pulse wave velocity estimation: a validation study with velocity-encoded cardiovascular magnetic resonance and invasive pressure assessment.

Authors:  Jos J M Westenberg; Eveline P van Poelgeest; Paul Steendijk; Heynric B Grotenhuis; J W Jukema; Albert de Roos
Journal:  J Cardiovasc Magn Reson       Date:  2012-01-09       Impact factor: 5.364

5.  Race/ethnicity determines the relationships between oxidative stress markers and blood pressure in individuals with high cardiovascular disease risk.

Authors:  G Kapuku; F Treiber; F Raouane; J Halbert; H Davis; S Young-Mayes; V Robinson; G Harshfield
Journal:  J Hum Hypertens       Date:  2016-06-16       Impact factor: 3.012

Review 6.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

7.  Incidence and correlates of high blood pressure from childhood to adulthood: the Birth to Twenty study.

Authors:  Romain Meer; Daniel Boateng; Kerstin Klipstein-Grobusch; Shane A Norris; Juliana Kagura
Journal:  J Hypertens       Date:  2022-02-01       Impact factor: 4.844

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.