Literature DB >> 24932058

Targeted Lung Delivery of Nasally Administered Aerosols.

Geng Tian1, Michael Hindle2, P Worth Longest3.   

Abstract

Using the nasal route to deliver pharmaceutical aerosols to the lungs has a number of advantages including co-administration during non-invasive ventilation. The objective of this study was to evaluate the growth and deposition characteristics of nasally administered aerosol throughout the conducting airways based on delivery with streamlined interfaces implementing two forms of controlled condensational growth technology. Characteristic conducting airways were considered including a nose-mouth-throat (NMT) geometry, complete upper tracheobronchial (TB) model through the third bifurcation (B3), and stochastic individual path (SIP) model to the terminal bronchioles (B15). Previously developed streamlined nasal cannula interfaces were used for the delivery of submicrometer particles using either enhanced condensational growth (ECG) or excipient enhanced growth (EEG) techniques. Computational fluid dynamics (CFD) simulations predicted aerosol transport, growth and deposition for a control (4.7 μm) and three submicrometer condensational aerosols with budesonide as a model insoluble drug. Depositional losses with condensational aerosols in the cannula and NMT were less than 5% of the initial dose, which represents an order-of-magnitude reduction compared to the control. The condensational growth techniques increased the TB dose by a factor of 1.1-2.6x, delivered at least 70% of the dose to the alveolar region, and produced final aerosol sizes ≥2.5 μm. Compared to multiple commercial orally inhaled products, the nose-to-lung delivery approach increased dose to the biologically important lower TB region by factors as large as 35x. In conclusion, nose-to-lung delivery with streamlined nasal cannulas and condensational aerosols was highly efficient and targeted deposition to the lower TB and alveolar regions.

Entities:  

Year:  2014        PMID: 24932058      PMCID: PMC4051279          DOI: 10.1080/02786826.2014.887829

Source DB:  PubMed          Journal:  Aerosol Sci Technol        ISSN: 0278-6826            Impact factor:   2.908


  48 in total

1.  Characterization of deposition from nasal spray devices using a computational fluid dynamics model of the human nasal passages.

Authors:  Julia S Kimbell; Rebecca A Segal; Bahman Asgharian; Brian A Wong; Jeffry D Schroeter; Jeremy P Southall; Colin J Dickens; Geoff Brace; Frederick J Miller
Journal:  J Aerosol Med       Date:  2007

2.  Effects of oral airway geometry characteristics on the diffusional deposition of inhaled nanoparticles.

Authors:  Jinxiang Xi; P Worth Longest
Journal:  J Biomech Eng       Date:  2008-02       Impact factor: 2.097

Review 3.  Idiopathic pulmonary fibrosis: spectrum of high-resolution CT findings.

Authors:  Carolina Althoff Souza; Nestor L Müller; Julia Flint; Joanne L Wright; Andrew Churg
Journal:  AJR Am J Roentgenol       Date:  2005-12       Impact factor: 3.959

4.  Targeting aerosol deposition to and within the lung airways using excipient enhanced growth.

Authors:  Geng Tian; P Worth Longest; Xiang Li; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2013-01-03       Impact factor: 2.849

5.  Performance of combination drug and hygroscopic excipient submicrometer particles from a softmist inhaler in a characteristic model of the airways.

Authors:  P Worth Longest; Geng Tian; Xiang Li; Yoen-Ju Son; Michael Hindle
Journal:  Ann Biomed Eng       Date:  2012-07-21       Impact factor: 3.934

6.  The use of condensational growth methods for efficient drug delivery to the lungs during noninvasive ventilation high flow therapy.

Authors:  Laleh Golshahi; Geng Tian; Mandana Azimi; Yoen-Ju Son; Ross Walenga; P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2013-06-26       Impact factor: 4.200

7.  In vitro comparison of heliox and oxygen in aerosol delivery using pediatric high flow nasal cannula.

Authors:  Arzu Ari; Robert Harwood; Meryl Sheard; Patricia Dailey; James B Fink
Journal:  Pediatr Pulmonol       Date:  2011-03-24

8.  Aerosolization characteristics of dry powder inhaler formulations for the excipient enhanced growth (EEG) application: effect of spray drying process conditions on aerosol performance.

Authors:  Yoen-Ju Son; P Worth Longest; Michael Hindle
Journal:  Int J Pharm       Date:  2013-01-10       Impact factor: 5.875

9.  Condensational growth of combination drug-excipient submicrometer particles for targeted high-efficiency pulmonary delivery: evaluation of formulation and delivery device.

Authors:  Michael Hindle; P Worth Longest
Journal:  J Pharm Pharmacol       Date:  2012-02-21       Impact factor: 3.765

10.  Interindividual variability in nasal filtration as a function of nasal cavity geometry.

Authors:  Guilherme J M Garcia; Earl W Tewksbury; Brian A Wong; Julia S Kimbell
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2009-06       Impact factor: 2.849

View more
  15 in total

1.  Application of an inline dry powder inhaler to deliver high dose pharmaceutical aerosols during low flow nasal cannula therapy.

Authors:  Dale Farkas; Michael Hindle; P Worth Longest
Journal:  Int J Pharm       Date:  2018-05-05       Impact factor: 5.875

Review 2.  Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs.

Authors:  Worth Longest; Benjamin Spence; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-07-09       Impact factor: 2.849

3.  Development of a High-Flow Nasal Cannula and Pharmaceutical Aerosol Combination Device.

Authors:  Benjamin M Spence; Worth Longest; Xiangyin Wei; Sneha Dhapare; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-03-11       Impact factor: 2.849

4.  Development of an Inline Dry Powder Inhaler for Oral or Trans-Nasal Aerosol Administration to Children.

Authors:  Dale Farkas; Michael Hindle; Serena Bonasera; Karl Bass; Worth Longest
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-08-29       Impact factor: 2.849

5.  Efficient Nose-to-Lung (N2L) Aerosol Delivery with a Dry Powder Inhaler.

Authors:  P Worth Longest; Laleh Golshahi; Srinivas R B Behara; Geng Tian; Dale R Farkas; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2014-09-05       Impact factor: 2.849

6.  Efficient Nose-to-Lung Aerosol Delivery with an Inline DPI Requiring Low Actuation Air Volume.

Authors:  Dale Farkas; Michael Hindle; P Worth Longest
Journal:  Pharm Res       Date:  2018-08-21       Impact factor: 4.200

7.  Validating Whole-Airway CFD Predictions of DPI Aerosol Deposition at Multiple Flow Rates.

Authors:  P Worth Longest; Geng Tian; Navvab Khajeh-Hosseini-Dalasm; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2016-04-15       Impact factor: 2.849

Review 8.  Use of computational fluid dynamics deposition modeling in respiratory drug delivery.

Authors:  P Worth Longest; Karl Bass; Rabijit Dutta; Vijaya Rani; Morgan L Thomas; Ahmad El-Achwah; Michael Hindle
Journal:  Expert Opin Drug Deliv       Date:  2018-12-10       Impact factor: 6.648

9.  Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data.

Authors:  Geng Tian; Michael Hindle; Sau Lee; P Worth Longest
Journal:  Pharm Res       Date:  2015-05-06       Impact factor: 4.200

10.  Small Airway Absorption and Microdosimetry of Inhaled Corticosteroid Particles after Deposition.

Authors:  P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2017-06-22       Impact factor: 4.200

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.