Literature DB >> 24906451

Separate pulmonary artery and vein magnetic resonance angiography by use of an arterial spin labeling method.

Tomoyuki Okuaki1, Tsuyoshi Ishimoto, Tosiaki Miyati, Satoshi Kobayashi, Masaru Ishihara, Momoe Kawakami, Tetsuo Ogino, Marc Van Cauteren.   

Abstract

A separate pulmonary vein (PV) is difficult to depict with the commonly used bright-blood magnetic resonance angiography method. Until now, no study has described the depiction of peripheral PVs without the artery. Our purpose in this study was to develop an arterial spin labeling (ASL)-based magnetic resonance angiography sequence to depict the pulmonary artery (PA) and vein separately. We developed such a sequence by using two inversion recovery pulses. The first pulse was non-selective, and the second pulse was selective and was applied to the aorta and heart. All studies were conducted on a 1.5-T clinical magnetic resonance system with six different inversion times for seven healthy volunteers. For evaluation, we categorized the inversion times by using visual scoring. Then, we used the magnitude image to evaluate the PA, and we used the real image to evaluate the PV. For the PA, an inversion time of 300 ms had the lowest score (1.43), and the score changed with increasing times; an inversion time of 1,100 ms had the highest score (3.85). For the PV, an inversion time of 300 ms had the highest score (2.68), and the score decreased with increasing times. The results indicated that the PA and vein could be depicted separately by the use of an ASL-based magnetic resonance angiography method. The optimal inversion times for the PV and artery were 300 and 1,100 ms, respectively.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24906451     DOI: 10.1007/s12194-014-0272-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  20 in total

1.  Oxygen-enhanced magnetic resonance ventilation imaging of the human lung at 0.2 and 1.5 T.

Authors:  K W Stock; Q Chen; M Morrin; H Hatabu; R R Edelman
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

3.  Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging.

Authors:  Mitsue Miyazaki; Hiroshi Takai; Satoshi Sugiura; Hirofumi Wada; Rie Kuwahara; Joji Urata
Journal:  Radiology       Date:  2003-04-17       Impact factor: 11.105

Review 4.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

5.  High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a spiral-TRICKS sequence.

Authors:  Jiang Du; Mark Bydder
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

Review 6.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

7.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

Authors:  J P Earls; N M Rofsky; D R DeCorato; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

8.  MR angiography by selective inversion recovery.

Authors:  D G Nishimura; A Macovski; J M Pauly; S M Conolly
Journal:  Magn Reson Med       Date:  1987-02       Impact factor: 4.668

9.  Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography.

Authors:  R R Edelman; B Siewert; M Adamis; J Gaa; G Laub; P Wielopolski
Journal:  Magn Reson Med       Date:  1994-02       Impact factor: 4.668

10.  MR gated subtraction angiography: evaluation of lower extremities.

Authors:  R A Meuli; V J Wedeen; S C Geller; R R Edelman; L R Frank; T J Brady; B R Rosen
Journal:  Radiology       Date:  1986-05       Impact factor: 11.105

View more
  1 in total

1.  Hemodynamic study of unenhanced magnetic resonance angiography using spatial labeling with multiple inversion pulses sequence: a phantom study.

Authors:  Xiao Chen; Xiaoyan Meng; Di Zhu; Xianlun Zou; Yaqi Shen; Zhen Li; Jian Peng; Daoyu Hu
Journal:  Quant Imaging Med Surg       Date:  2021-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.