Literature DB >> 24896644

Validation of heart rate derived from a physiological status monitor-embedded compression shirt against criterion ECG.

B A Dolezal1, D M Boland, J Carney, M Abrazado, D L Smith, C B Cooper.   

Abstract

Firefighters are subject to extreme environments and high physical demands when performing duty-related tasks. Recently, physiological status monitors (PSM) have been embedded into a compression shirt to enable firefighters to measure, visualize, log, and transmit vital metrics such as heart rate (HR) to aid in cardiovascular risk identification and mitigation, thereby attempting to improve the health, fitness, and safety of this population. The purpose of this study was to validate HR recorded by the PSM-embedded compression shirt against a criterion standard laboratory ECG-derived HR when worn concurrently with structural firefighting personal protective equipment (PPE) during four simulated firefighting activities. Ten healthy, college-age men (mean ± SD: age: 21 ± 1 yr; body mass: 91 ± 10 kg; body mass index: 26.9 ± 3.1 kg/m(2)) completed four tasks that are routinely performed during firefighting operations: outdoor fast-paced walking (FW), treadmill walking (TW), searching/crawling (SC), and ascending/descending stairs (AD). They wore the PSM-embedded compression shirt under structural firefighting PPE. HR was recorded concurrently by the PSM-embedded compression shirt and a portable metabolic measurement system accompanied with a standard 12-lead electrocardiograph that was used to provide criterion measures of HR. For all four tasks combined there was very high correlation of PSM and ECG HR (r > 0.99; SEE 0.84 /min) with a mean difference (bias) of -0.02 /min and limits of agreement of -0.07 to 0.02 /min. For individual tasks, the correlations were also high (r-values = 0.99; SEE 0.81-0.89). The mean bias (limits of agreement) was: FW 0.03 (-0.09 to 0.14); TW 0.04 (-0.05 to 0.12); SC -0.01 (-0.12 to 0.10); AD -0.13 (-0.21 to -0.04) /min. These findings demonstrate that the PSM-embedded compression shirt provides a valid measure of HR during simulated firefighting activities when compared with a standard 12-lead ECG.

Entities:  

Keywords:  PSM; heart rate; remote monitoring

Mesh:

Year:  2014        PMID: 24896644     DOI: 10.1080/15459624.2014.925114

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  10 in total

1.  Inter-Instrument Reliability and Agreement of Fitbit Charge Measurements of Heart Rate and Activity at Rest, during the Modified Canadian Aerobic Fitness Test, and in Recovery.

Authors:  Goris Nazari; Joy C MacDermid; Kathryn E Sinden; Julie Richardson; Ada Tang
Journal:  Physiother Can       Date:  2019       Impact factor: 1.037

2.  Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.

Authors:  Edward Jo; Kiana Lewis; Dean Directo; Michael J Kim; Brett A Dolezal
Journal:  J Sports Sci Med       Date:  2016-08-05       Impact factor: 2.988

3.  Wearable Cardiorespiratory Sensors for Aerospace Applications.

Authors:  Nichakorn Pongsakornsathien; Alessandro Gardi; Yixiang Lim; Roberto Sabatini; Trevor Kistan
Journal:  Sensors (Basel)       Date:  2022-06-21       Impact factor: 3.847

4.  Cost-effectiveness of workplace wellness to prevent cardiovascular events among U.S. firefighters.

Authors:  P Daniel Patterson; Kenneth J Smith; David Hostler
Journal:  BMC Cardiovasc Disord       Date:  2016-11-21       Impact factor: 2.298

Review 5.  Smart Shirts for Monitoring Physiological Parameters: Scoping Review.

Authors:  Hamzeh Khundaqji; Wayne Hing; James Furness; Mike Climstein
Journal:  JMIR Mhealth Uhealth       Date:  2020-05-27       Impact factor: 4.773

6.  Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities.

Authors:  Imali T Hettiarachchi; Samer Hanoun; Darius Nahavandi; Saeid Nahavandi
Journal:  PLoS One       Date:  2019-05-23       Impact factor: 3.240

7.  Continuous Monitoring of Vital Signs With Wearable Sensors During Daily Life Activities: Validation Study.

Authors:  Marjolein E Haveman; Mathilde C van Rossum; Roswita M E Vaseur; Claire van der Riet; Richte C L Schuurmann; Hermie J Hermens; Jean-Paul P M de Vries; Monique Tabak
Journal:  JMIR Form Res       Date:  2022-01-07

8.  Heart rate variability and heart rate monitoring of nurses using PPG and ECG signals during working condition: A pilot study.

Authors:  Xinxia Li; Chenghong Hu; Airong Meng; Yanmei Guo; Yang Chen; Rongqing Dang
Journal:  Health Sci Rep       Date:  2022-01-19

9.  Psychometric properties of the Zephyr bioharness device: a systematic review.

Authors:  Goris Nazari; Pavlos Bobos; Joy C MacDermid; Kathryn E Sinden; Julie Richardson; Ada Tang
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-02-21

10.  Use of a Wearable Biosensor to Study Heart Rate Variability in Chronic Obstructive Pulmonary Disease and Its Relationship to Disease Severity.

Authors:  Seon-Cheol Park; Narongkorn Saiphoklang; Donghyun Jung; David Gomez; Jonathan E Phillips; Brett A Dolezal; Donald P Tashkin; Igor Barjaktarevic; Christopher B Cooper
Journal:  Sensors (Basel)       Date:  2022-03-15       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.