Literature DB >> 24892369

Intracochlear electrocochleography during cochlear implantation.

Nathan H Calloway1, Douglas C Fitzpatrick, Adam P Campbell, Claire Iseli, Stephen Pulver, Craig A Buchman, Oliver F Adunka.   

Abstract

OBJECTIVE: Electrophysiologic responses to acoustic stimuli are present in nearly all cochlear implant recipients when measured at the round window (RW). Intracochlear recording sites might provide an even larger signal and improve the sensitivity and the potential clinical utility of electrocochleography (ECoG). Thus, the goal of this study is to compare RW to intracochlear recording sites and to determine if such recordings can be used to monitor cochlear function during insertion of a cochlear implant.
METHODS: Intraoperative ECoG recordings were obtained in subjects receiving a cochlear implant from the RW and from just inside scala tympani (n = 26). Stimuli were tones at high levels (80-100 dB HL). Further recordings were obtained during insertions of a temporary lateral cochlear wall electrode (n = 8). Response magnitudes were determined as the sum of the first and second harmonics amplitudes.
RESULTS: All subjects had measurable extracochlear responses at the RW. Twenty cases (78%) showed a larger intracochlear response, compared with three (11%) that had a smaller response and three that were unchanged. On average, signal amplitudes increased with increasing electrode insertion depths, with the largest increase between 15 and 20 mm from the RW.
CONCLUSION: ECoG to acoustic stimuli via an intracochlear electrode is feasible in standard cochlear implant recipients. The increased signal can improve the speed and efficiency of data collection. The growth of response magnitudes with deeper intrascalar electrode positions could be explained by closer proximity or favorable geometry with respect to residual apical signal generators. Reductions in magnitude may represent unfavorable geometry or cochlear trauma.

Entities:  

Mesh:

Year:  2014        PMID: 24892369     DOI: 10.1097/MAO.0000000000000451

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  22 in total

1.  Using Neural Response Telemetry to Monitor Physiological Responses to Acoustic Stimulation in Hybrid Cochlear Implant Users.

Authors:  Paul J Abbas; Viral D Tejani; Rachel A Scheperle; Carolyn J Brown
Journal:  Ear Hear       Date:  2017 Jul/Aug       Impact factor: 3.570

2.  Patterns Seen During Electrode Insertion Using Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant.

Authors:  Michael S Harris; William J Riggs; Christopher K Giardina; Brendan P O'Connell; Jourdan T Holder; Robert T Dwyer; Kanthaiah Koka; Robert F Labadie; Douglas C Fitzpatrick; Oliver F Adunka
Journal:  Otol Neurotol       Date:  2017-12       Impact factor: 2.311

3.  Hair cell and neural contributions to the cochlear summating potential.

Authors:  Andrew K Pappa; Kendall A Hutson; William C Scott; J David Wilson; Kevin E Fox; Maheer M Masood; Christopher K Giardina; Stephen H Pulver; Gilberto D Grana; Charles Askew; Douglas C Fitzpatrick
Journal:  J Neurophysiol       Date:  2019-04-03       Impact factor: 2.714

4.  Cochlear Microphonics in Hearing Preservation Cochlear Implantees.

Authors:  Artur Lorens; Adam Walkowiak; Marek Polak; Aleksandra Kowalczuk; Mariusz Furmanek; Henryk Skarzynski; Anita Obrycka
Journal:  J Int Adv Otol       Date:  2019-12       Impact factor: 1.017

5.  Early Hearing Preservation Outcomes Following Cochlear Implantation With New Slim Lateral Wall Electrode Using Electrocochleography.

Authors:  Amit Walia; Matthew A Shew; Abhinav Ettyreddy; Shannon M Lefler; Pawina Jiramongkolchai; Cameron C Wick; Nedim Durakovic; Craig A Buchman; Jacques A Herzog
Journal:  Otol Neurotol       Date:  2022-04-01       Impact factor: 2.311

6.  Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.

Authors:  Christopher K Giardina; Tatyana E Khan; Stephen H Pulver; Oliver F Adunka; Craig A Buchman; Kevin D Brown; Harold C Pillsbury; Douglas C Fitzpatrick
Journal:  Ear Hear       Date:  2018 Nov/Dec       Impact factor: 3.570

7.  Round window electrocochleography before and after cochlear implant electrode insertion.

Authors:  Oliver F Adunka; Christopher K Giardina; Eric J Formeister; Baishakhi Choudhury; Craig A Buchman; Douglas C Fitzpatrick
Journal:  Laryngoscope       Date:  2015-09-11       Impact factor: 3.325

8.  Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation.

Authors:  Christopher K Giardina; Kevin D Brown; Oliver F Adunka; Craig A Buchman; Kendall A Hutson; Harold C Pillsbury; Douglas C Fitzpatrick
Journal:  Ear Hear       Date:  2019 Jul/Aug       Impact factor: 3.570

Review 9.  Electrocochleography in cochlear implantation: Development, applications, and future directions.

Authors:  Jason H Barnes; Linda X Yin; Aniket A Saoji; Matthew L Carlson
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2020-06-04

10.  Intracochlear Electrocochleography and Speech Perception Scores in Cochlear Implant Recipients.

Authors:  Carla V Valenzuela; Jeffery T Lichtenhan; Shannon M Lefler; Kanthaiah Koka; Craig A Buchman; Amanda J Ortmann
Journal:  Laryngoscope       Date:  2021-05-21       Impact factor: 2.970

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.