Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system.

Lorraine Courneyea1, Chris Beltran1, Hok Seum Wan Chan Tseung1, Juan Yu1, Michael G Herman1.   

Abstract

PURPOSE: Study the contributors to treatment time as a function of Mini-Ridge Filter (MRF) thickness to determine the optimal choice for breath-hold treatment of lung tumors in a synchrotron-based spot-scanning proton machine.
METHODS: Five different spot-scanning nozzles were simulated in TOPAS: four with MRFs of varying maximal thicknesses (6.15-24.6 mm) and one with no MRF. The MRFs were designed with ridges aligned along orthogonal directions transverse to the beam, with the number of ridges (4-16) increasing with MRF thickness. The material thickness given by these ridges approximately followed a Gaussian distribution. Using these simulations, Monte Carlo data were generated for treatment planning commissioning. For each nozzle, standard and stereotactic (SR) lung phantom treatment plans were created and assessed for delivery time and plan quality.
RESULTS: Use of a MRF resulted in a reduction of the number of energy layers needed in treatment plans, decreasing the number of synchrotron spills needed and hence the treatment time. For standard plans, the treatment time per field without a MRF was 67.0 ± 0.1 s, whereas three of the four MRF plans had treatment times of less than 20 s per field; considered sufficiently low for a single breath-hold. For SR plans, the shortest treatment time achieved was 57.7 ± 1.9 s per field, compared to 95.5 ± 0.5 s without a MRF. There were diminishing gains in time reduction as the MRF thickness increased. Dose uniformity of the PTV was comparable across all plans; however, when the plans were normalized to have the same coverage, dose conformality decreased with MRF thickness, as measured by the lung V20%.
CONCLUSIONS: Single breath-hold treatment times for plans with standard fractionation can be achieved through the use of a MRF, making this a viable option for motion mitigation in lung tumors. For stereotactic plans, while a MRF can reduce treatment times, multiple breath-holds would still be necessary due to the limit imposed by the proton extraction time. To balance treatment time and normal tissue dose, the ideal MRF choice was shown to be the thinnest option that is able to achieve the desired breath-hold timing.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24877808     DOI: 10.1118/1.4876276

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

Review 1.  Proton therapy delivery: what is needed in the next ten years?

Authors:  Andries N Schreuder; Jacob Shamblin
Journal:  Br J Radiol       Date:  2019-11-14       Impact factor: 3.039

2.  Ultra-high dose rate radiation production and delivery systems intended for FLASH.

Authors:  Jonathan Farr; Veljko Grilj; Victor Malka; Srinivasan Sudharsan; Marco Schippers
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

3.  Technical Delivery Parameters of 2000 Proton Treatment Courses.

Authors:  Amanda J Deisher; Thomas J Whitaker; Chris J Beltran; Robert L Foote; Michael G Haddock; Anita Mahajan
Journal:  Int J Part Ther       Date:  2020-02-21

4.  Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery.

Authors:  Xianliang Wang; Yupeng Li; Xiaodong Zhang; Heng Li; Koichi Miyazaki; Rintaro Fujimoto; Hiroshi Akiyama; Michael T Gillin; Falk Poenisch; Narayan Sahoo; David Grosshans; Brandon Gunn; Steven Jay Frank; Pei Wang; Jinyi Lang; Qing Hou; Xiaorong Ronald Zhu
Journal:  Cancers (Basel)       Date:  2017-12-13       Impact factor: 6.639

5.  Developing an accurate model of spot-scanning treatment delivery time and sequence for a compact superconducting synchrocyclotron proton therapy system.

Authors:  Lewei Zhao; Gang Liu; Shupeng Chen; Jiajian Shen; Weili Zheng; An Qin; Di Yan; Xiaoqiang Li; Xuanfeng Ding
Journal:  Radiat Oncol       Date:  2022-05-07       Impact factor: 4.309

6.  Analysis of treatment process time for real-time-image gated-spot-scanning proton-beam therapy (RGPT) system.

Authors:  Takaaki Yoshimura; Shinichi Shimizu; Takayuki Hashimoto; Kentaro Nishioka; Norio Katoh; Tetsuya Inoue; Hiroshi Taguchi; Koichi Yasuda; Taeko Matsuura; Seishin Takao; Masaya Tamura; Yoichi M Ito; Yuto Matsuo; Hiroshi Tamura; Kenji Horita; Kikuo Umegaki; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2019-12-30       Impact factor: 2.102

7.  Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data.

Authors:  Takaaki Yoshimura; Shinichi Shimizu; Takayuki Hashimoto; Kentaro Nishioka; Norio Katoh; Hiroshi Taguchi; Koichi Yasuda; Taeko Matsuura; Seishin Takao; Masaya Tamura; Sodai Tanaka; Yoichi M Ito; Yuto Matsuo; Hiroshi Tamura; Kenji Horita; Kikuo Umegaki; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2020-11-05       Impact factor: 2.102

Review 8.  Future Developments in Charged Particle Therapy: Improving Beam Delivery for Efficiency and Efficacy.

Authors:  Jacinta Yap; Andrea De Franco; Suzie Sheehy
Journal:  Front Oncol       Date:  2021-12-09       Impact factor: 5.738

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.