Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

Mayank Lau1, G S Amarnath2, B C Muddugangadhar2, M U Swetha2, Kopal Anshuraj Ashok Kumar Das2.   

Abstract

BACKGROUND: The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. MATERIALS &
METHODS: 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups.
RESULTS: The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors.
CONCLUSION: The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the article: Lau M, Amarnath GS, Muddugangadhar BC, Swetha MU, Das KA. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study. J Int Oral Health 2014;6(2):55-61.

Entities:  

Keywords:  G C reline; mollosil; reliners; shear bond strength; tensile bond strength; ufi gel hard

Year:  2014        PMID: 24876703      PMCID: PMC4037796     

Source DB:  PubMed          Journal:  J Int Oral Health        ISSN: 0976-1799


  17 in total

1.  Evaluation of bond strength of soft relining materials to denture base polymers.

Authors:  Mustafa Murat Mutluay; I Eystein Ruyter
Journal:  Dent Mater       Date:  2007-01-12       Impact factor: 5.304

2.  Shear bond strength of two chemically different denture base polymers to reline materials.

Authors:  Fauziah Ahmad; McLin Dent; Norsiah Yunus
Journal:  J Prosthodont       Date:  2009-06-08       Impact factor: 2.752

3.  The bond strength of a visible light-cured reline resin to acrylic resin denture base material.

Authors:  R Razavi; Z Khan; J A von Fraunhofer
Journal:  J Prosthet Dent       Date:  1990-04       Impact factor: 3.426

4.  Swelling of poly(methyl methacrylate) resin at the repair joint.

Authors:  P K Vallittu; I E Ruyter
Journal:  Int J Prosthodont       Date:  1997 May-Jun       Impact factor: 1.681

5.  Some factors affecting the transverse strength of repaired denture acrylic resin.

Authors:  P K Vallittu
Journal:  Eur J Prosthodont Restor Dent       Date:  1996-03

6.  Evaluation of adhesion of chairside hard relining materials to denture base polymers.

Authors:  Mustafa Murat Mutluay; I Eystein Ruyter
Journal:  J Prosthet Dent       Date:  2005-11       Impact factor: 3.426

7.  Bond strength and failure analysis of lining materials to denture resin.

Authors:  A K Aydin; H Terzioğlu; A E Akinay; K Ulubayram; N Hasirci
Journal:  Dent Mater       Date:  1999-05       Impact factor: 5.304

8.  Water sorption, solubility, and bond strength of two autopolymerizing acrylic resins and one heat-polymerizing acrylic resin.

Authors:  A L Cucci; C E Vergani; E T Giampaolo; M C Afonso
Journal:  J Prosthet Dent       Date:  1998-10       Impact factor: 3.426

9.  Transverse bond strength of repaired acrylic resin strips and temperature rise of dentures relined with VLC reline resin.

Authors:  I Lewinstein; C Zeltser; C M Mayer; Y Tal
Journal:  J Prosthet Dent       Date:  1995-10       Impact factor: 3.426

10.  Comparison of bond strength of six soft denture liners to denture base resin.

Authors:  F Kawano; E R Dootz; A Koran; R G Craig
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

View more
  3 in total

Review 1.  Long-Term Soft Denture Lining Materials.

Authors:  Grzegorz Chladek; Jarosław Żmudzki; Jacek Kasperski
Journal:  Materials (Basel)       Date:  2014-08-12       Impact factor: 3.623

2.  Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base.

Authors:  Farhang Mahboub; Fariba Salehsaber; Fereydoon Parnia; Vahedeh Gharekhani; Yousef Kananizadeh; Mahsa Taghizadeh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20

3.  Biological and immunotoxicity evaluation of antimicrobial peptide-loaded coatings using a layer-by-layer process on titanium.

Authors:  Jue Shi; Yu Liu; Ying Wang; Jing Zhang; Shifang Zhao; Guoli Yang
Journal:  Sci Rep       Date:  2015-11-09       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.