Literature DB >> 19515166

Shear bond strength of two chemically different denture base polymers to reline materials.

Fauziah Ahmad1, McLin Dent, Norsiah Yunus.   

Abstract

PURPOSE: This study evaluated the shear bond strengths of light-polymerized urethane dimethacrylate (Eclipse) and heat-polymerized polymethylmethacrylate (Meliodent) denture base polymers to intraoral and laboratory-processed reline materials.
MATERIALS AND METHODS: Thirty disks measuring 15 mm diameter and 2 mm thick were prepared for each denture base material following the manufacturers' recommendation. They were relined with Meliodent RR, Kooliner, and Secure reline materials after 1 month of water immersion. Ten additional Eclipse specimens were relined using the same Eclipse resin. A shear bond test was carried out on an Instron machine at a crosshead speed of 1.0 mm/min 24 hours after relining. Data were analyzed using two-way and one-way ANOVAs and post hoc Dunnett's T3 test (p= 0.05). The nature of failure was analyzed under a stereomicroscope. The effect of dichloromethane adhesive on the two denture polymer surfaces and the failed interfaces of mixed and adhesive failures were analyzed under a SEM (scanning electron microscope).
RESULTS: Two-way ANOVA showed significant differences in the shear bond strength values as a function of the denture base polymers, reline materials, and their interaction (p < 0.05). One-way ANOVA showed significant differences in shear bond strength values among denture base-reline combinations (p < 0.05) except for Meliodent-Kooliner and Eclipse-Meliodent RR relines. Meliodent showed the highest shear bond strength value when relined with Meliodent RR (14.5 +/- 0.5 MPa), and Eclipse showed the highest value with Eclipse relining (11.4 +/- 0.6 MPa). Meliodent denture base showed adhesive, cohesive, and mixed failure, while all Eclipse showed adhesive failure with various reline materials.
CONCLUSION: The two chemically different denture base polymers showed different shear bond strength values to corresponding reline materials.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19515166     DOI: 10.1111/j.1532-849X.2009.00481.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  7 in total

1.  Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

Authors:  Hakan Akin; Faik Tugut; Umit Guney; Omer Kirmali; Turker Akar
Journal:  Lasers Med Sci       Date:  2012-03-25       Impact factor: 3.161

2.  Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

Authors:  Mayank Lau; G S Amarnath; B C Muddugangadhar; M U Swetha; Kopal Anshuraj Ashok Kumar Das
Journal:  J Int Oral Health       Date:  2014-04-26

3.  Clinical performance of a light-cured denture base material compared to polymethylmethacrylate--a randomized clinical study.

Authors:  Hanna-Lena Gohlke-Wehrße; Katja Giese-Kraft; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2011-06-08       Impact factor: 3.573

4.  Comparison of shear bond strength of CAD/CAM and conventional heat-polymerized acrylic resin denture bases to auto-polymerized and heat-polymerized acrylic resins after aging.

Authors:  Masoumeh Taghva; Shabnam Enteghad; Ali Jamali; Mina Mohaghegh
Journal:  J Clin Exp Dent       Date:  2022-01-01

5.  Anticandidal activity and biocompatibility of a rechargeable antifungal denture material.

Authors:  C C Villar; A L Lin; Z Cao; X-R Zhao; L-A Wu; S Chen; Y Sun; C-K Yeh
Journal:  Oral Dis       Date:  2012-09-07       Impact factor: 3.511

6.  Effect of Food Simulating Agents on the Hardness and Bond Strength of a Silicone Soft Liner to a Denture Base Acrylic Resin.

Authors:  A A R Khaledi; M Bahrani; S Shirzadi
Journal:  Open Dent J       Date:  2015-12-23

7.  Denture Liners: A Systematic Review Relative to Adhesion and Mechanical Properties.

Authors:  Simone Kreve; Andréa C Dos Reis
Journal:  ScientificWorldJournal       Date:  2019-03-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.