Abstract

OBJECTIVES: To determine the optimal iodine mass (IM) to achieve a 50-HU increase in hepatic attenuation for the detection of liver metastasis based on total body weight (TBW) or body surface area (BSA) at 80-kVp computed tomography (CT) imaging of the liver.
METHODS: One-hundred and fifty patients who underwent contrast-enhanced CT at 80-kVp were randomised into three groups: 0.5 gI/kg, 0.4 gI/kg and 0.3 gI/kg. Portal venous phase images were evaluated for hepatic parenchymal enhancement (∆HU) and visualisation of liver metastasis. Iodine mass per BSA (gI/m(2)) calculated in individual patients were evaluated.
RESULTS: Mean ∆HU for the 0.5 gI/kg group (84.2 HU) was higher than in the 0.4 gI/kg (66.1 HU) and 0.3 gI/kg (53.7 HU) groups (P < 0.001). Linear correlation equations between ∆HU and IM per TBW or BSA are ∆HU = 7.0 + 153.0 × IM/TBW (r = 0.73, P < 0.001) and ∆HU = 11.4 + 4.0 × IM/BSA (r = 0.75, P < 0.001), respectively. The three groups were comparable for the visualisation of hepatic metastases.
CONCLUSIONS: The iodine mass to achieve a 50-HU increase in hepatic attenuation at 80-kVp CT was estimated to be 0.28 gI/kg of body weight or 9.6 gI/m(2) of body surface area. KEY POINTS: • Hepatic enhancement is expressed as ∆HU = 7.0 + 153.0 × IM [g]/TBW [kg]. • Hepatic enhancement is expressed as ∆HU = 11.4 + 4.0 × IM [g]/BSA [m(2)]. • Essential iodine dose at 80-kVp CT was 0.28 gI/kg or 9.6 gI/m(2).

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24865696     DOI: 10.1007/s00330-014-3227-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2003-04-17       Impact factor: 11.105

3.  Low contrast agent and radiation dose protocol for hepatic dynamic CT of thin adults at 256-detector row CT: effect of low tube voltage and hybrid iterative reconstruction algorithm on image quality.

Authors:  Takeshi Nakaura; Shinichi Nakamura; Natsuki Maruyama; Yoshinori Funama; Kazuo Awai; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  Radiology       Date:  2012-05-24       Impact factor: 11.105

4.  Effect of injection rate of contrast medium on pancreatic and hepatic helical CT.

Authors:  M E Tublin; F N Tessler; S L Cheng; T L Peters; P C McGovern
Journal:  Radiology       Date:  1999-01       Impact factor: 11.105

5.  A quantitative theory of the Hounsfield unit and its application to dual energy scanning.

Authors:  R A Brooks
Journal:  J Comput Assist Tomogr       Date:  1977-10       Impact factor: 1.826

Review 6.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

7.  Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Masahiro Hatemura; Masanori Imuta; Takeshi Nakaura; Da Ryu; Shoji Morishita; Shamima Sultana; Natsuko Sato; Yasuyuki Yamashita
Journal:  Radiology       Date:  2005-10-19       Impact factor: 11.105

8.  Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT.

Authors:  Kazuo Awai; Koichi Takada; Hiromitsu Onishi; Shinichi Hori
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

9.  Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity.

Authors:  Kyongtae T Bae; Brian A Seeck; Charles F Hildebolt; Cheng Tao; Fang Zhu; Masayuki Kanematsu; Pamela K Woodard
Journal:  AJR Am J Roentgenol       Date:  2008-03       Impact factor: 3.959

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  3 in total

1.  Finding the optimal tube current and iterative reconstruction strength in liver imaging; two needles in one haystack.

Authors:  Bibi Martens; Joris G A Bosschee; Sander M J Van Kuijk; Cécile R L P N Jeukens; Maikel T H Brauer; Joachim E Wildberger; Casper Mihl
Journal:  PLoS One       Date:  2022-04-07       Impact factor: 3.240

2.  Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis.

Authors:  Daan J de Jong; Véronique V van Cooten; Wouter B Veldhuis; Pim A de Jong; Madeleine Kok
Journal:  Diagnostics (Basel)       Date:  2022-06-25

3.  Low kV Computed Tomography of Parenchymal Abdominal Organs-A Systematic Animal Study of Different Contrast Media Injection Protocols.

Authors:  Daniel Overhoff; Gregor Jost; Michael McDermott; Olaf Weber; Hubertus Pietsch; Stefan O Schoenberg; Ulrike Attenberger
Journal:  Tomography       Date:  2021-11-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.