Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases.

Shenglin Wang1, Chao Wang, Kirkham B Wood, Ming Yan, Haitao Zhou.   

Abstract

STUDY
DESIGN: Retrospective radiographic study of the technique for C1 lateral mass screw (C1LMS) and C2 pedicle screw (C2PS) fixation.
OBJECTIVE: To evaluate (1) the accuracy of the C1LMS and C2PS placement; (2) the fusion rate between C1 and C2; (3) the risk for vertebral artery (VA) injury. SUMMARY OF BACKGROUND DATA: C1LMS and C2PS fixation is widely used when treating atlantoaxial instability. Several authors have reported their experience focusing on the technical outcomes, with many reporting fusion rates near 100%. However, most of them are relatively small series, and many have applied only plain postoperative radiographs instead of computed tomography (CT). Thus, we feel that the accuracy of C1LMS and C2PS placement has not been fully analyzed, as well as the anatomic relationship between the VA and the screws.
METHODS: Between December 2000 and September 2008, the fusion status and accuracy of the screws were evaluated on the postoperative reconstructive CT of 319 patients with atlantoaxial instability. Cases with malpositioned screws underwent CT angiography or magnetic resonance angiography after surgery, to evaluate potential VA injury.
RESULTS: C1LMS of 95.5% and C2PS of 92.8% were found to be in a "good" position. After 2007, six cases had malpositioned screws, which were all in the "out" or "down" area of the C2 pedicle. Five cases underwent CT angiography and 1 had magnetic resonance angiography to evaluate potential VA injury. No occlusion, associated aneurysm or fistula of the VA was found. All cases (100%) achieved solid fusion between C1 and C2.
CONCLUSION: C1LMS of 95.5% and C2PS of 92.8% were confirmed to be in good position. None of the screws including the malpositioned caused VA injury, clinically or radiographically. The technique for C1LMS and C2PS fixation appears to be safe and effective.

Entities:  

Mesh:

Year:  2011        PMID: 20693942     DOI: 10.1097/BRS.0b013e3181c97dc7

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  14 in total

1.  The options of C2 fixation for os odontoideum: a radiographic study for the C2 pedicle and lamina anatomy.

Authors:  Xian-zhong Meng; Jia-xin Xu
Journal:  Eur Spine J       Date:  2011-07-03       Impact factor: 3.134

2.  The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass screw fixation for atlantoaxial instability.

Authors:  Da-Geng Huang; Ding-Jun Hao; Yong-Hong Jiang; Yue Cheng; Jun-Wei Pan; Yong-Qian Qiang; Bao-Rong He; Li-Xiong Qian
Journal:  Eur Spine J       Date:  2014-02-26       Impact factor: 3.134

3.  Radiological Efficacy of Cervical Lateral Mass Screw Insertion and Rod Fixation by Modified Magerl's Method (Yoon's Method) with Minimum 2 Years of Follow-up.

Authors:  Do Yeon Kim; Ji Yong Kim; Seung Hwan Yoon; Hyung Chun Park; Chong Oon Park
Journal:  Korean J Spine       Date:  2012-09-30

4.  Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients.

Authors:  Xueshi Li; Fuzhi Ai; Hong Xia; Zenghui Wu; Xiangyang Ma; Qingshui Yin
Journal:  Eur Spine J       Date:  2014-05-17       Impact factor: 3.134

5.  C1-C2 fusion: postoperative C2 nerve impingement-is it a problem?

Authors:  Kurt D Myers; Emily M Lindley; Evalina L Burger; Vikas V Patel
Journal:  Evid Based Spine Care J       Date:  2012-02

6.  Posterior pedicle screw fixation for complex atlantoaxial fractures with atlanto-dental interval of ≥ 5 mm or C2-C3 angulation of ≥ 11°.

Authors:  Lei Wang; Chao Liu; Qinghua Zhao; Jiwei Tian
Journal:  J Orthop Surg Res       Date:  2014-11-19       Impact factor: 2.359

7.  Machined cervical interfacet allograft spacers for the management of atlantoaxial instability.

Authors:  Mazda K Turel; Mena G Kerolus; Vincent C Traynelis
Journal:  J Craniovertebr Junction Spine       Date:  2017 Oct-Dec

8.  Comparison of occipitocervical and atlantoaxial fusion in treatment of unstable Jefferson fractures.

Authors:  Yong Hu; Zhen-Shan Yuan; Christopher K Kepler; Wei-Xin Dong; Xiao-Yang Sun; Jiao Zhang
Journal:  Indian J Orthop       Date:  2017 Jan-Feb       Impact factor: 1.251

9.  Anterior transarticular screw fixation for atlantoaxial arthrodesis: A report of two cases.

Authors:  C S Carrier; A A Sama; F P Girardi; D R Lebl
Journal:  J Craniovertebr Junction Spine       Date:  2013-07

Review 10.  Improving C1-C2 Complex Fusion Rates: An Alternate Approach.

Authors:  Samer S Ghostine; Paul E Kaloostian; Christ Ordookhanian; Sean Kaloostian; Parham Zarrini; Terrence Kim; Stephen Scibelli; Scott J Clark-Schoeb; Srinath Samudrala; Carl Lauryssen; Amandip S Gill; Patrick J Johnson
Journal:  Cureus       Date:  2017-11-29
View more