Literature DB >> 24827970

The effect of a manufacturer recall on the threshold to revise a metal-on-metal hip.

Saket Tibrewal1, Shiraz Sabah, Johann Henckel, Alister Hart.   

Abstract

PURPOSE: Management of the unexplained, painful large diameter metal-on-metal (MOM) hip replacement is difficult. Although there are guidelines for surgeons, there is no clear documented evidence describing the overall threshold for revision surgery. The 2010 product recall of the DePuy Articular Surface Replacement (ASR) and subsequent media coverage may have increased patient and surgeon apprehension, resulting in earlier intervention, i.e. at a greater Oxford hip score (OHS) than expected. Our aim was to investigate whether the threshold for revision using known parameters was affected by the ASR recall. These parameters include poor clinical results (persistent pain or mechanical symptoms), pseudotumour or other progressive soft tissue involvement, osteolysis and high or rising metal ion levels.
METHODS: We used our national referral database of MOM hips, which were revised between 2008 and 2012. Once inclusion and exclusion criteria were applied, we identified 240 patients--71 patients in the pre-recall group and 169 patients in the post-recall group.
RESULTS: The ASR product recall did not seem to affect the threshold for revision of a MOM hip, with no significant difference between the two groups in terms of the functional (median OHS = 17 pre-recall and 20 post-recall; p = 0.2109) and radiological (median inclination angle = 50 pre-recall and 48 post-recall; p = 0.3221) markers used to guide management. We did however discover that blood metal ion levels were higher in the post-recall group.
CONCLUSION: Issue of a product recall did not change the hip function threshold for revision surgery. The decision to revise a metal-on-metal hip is complex and should follow published guidelines, encompassing metal ion measurement and cross-sectional imaging where appropriate.

Entities:  

Mesh:

Year:  2014        PMID: 24827970     DOI: 10.1007/s00264-014-2369-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  10 in total

Review 1.  Metal-on-metal bearings: the evidence so far.

Authors:  F S Haddad; R R Thakrar; A J Hart; J A Skinner; A V F Nargol; J F Nolan; H S Gill; D W Murray; A W Blom; C P Case
Journal:  J Bone Joint Surg Br       Date:  2011-05

2.  Hip resurfacings revised for inflammatory pseudotumour have a poor outcome.

Authors:  G Grammatopoulos; G Grammatopolous; H Pandit; Y-M Kwon; R Gundle; P McLardy-Smith; D J Beard; D W Murray; H S Gill
Journal:  J Bone Joint Surg Br       Date:  2009-08

Review 3.  Perspectives in managing an implant recall: revision of 94 Durom Metasul acetabular components.

Authors:  Vincent Y Ng; Lindsay Arnott; Michael A McShane
Journal:  J Bone Joint Surg Am       Date:  2011-09-07       Impact factor: 5.284

4.  Commentary: Metal on metal hips.

Authors:  John Skinner; Peter Kay
Journal:  BMJ       Date:  2011-05-13

5.  Lessons of a hip failure.

Authors:  S K Muirhead-Allwood
Journal:  BMJ       Date:  1998-02-28

6.  The 2012 Otto Aufranc Award: The interpretation of metal ion levels in unilateral and bilateral hip resurfacing.

Authors:  Catherine Van Der Straeten; George Grammatopoulos; Harinderjit S Gill; Alessandro Calistri; Patricia Campbell; Koen A De Smet
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

7.  Metal-on-metal failures--in science, regulation, and policy.

Authors:  Art Sedrakyan
Journal:  Lancet       Date:  2012-03-13       Impact factor: 79.321

8.  Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty.

Authors:  Mitchell Bernstein; Nicholas M Desy; Alain Petit; David J Zukor; Olga L Huk; John Antoniou
Journal:  Int Orthop       Date:  2012-06-09       Impact factor: 3.075

9.  Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia.

Authors:  A J Hart; J A Skinner; P Winship; N Faria; E Kulinskaya; D Webster; S Muirhead-Allwood; C H Aldam; H Anwar; J J Powell
Journal:  J Bone Joint Surg Br       Date:  2009-06

10.  Hip resurfacing in patients under thirty years old: an attractive option for young and active patients.

Authors:  Nicolas Krantz; Bruno Miletic; Henri Migaud; Julien Girard
Journal:  Int Orthop       Date:  2012-05-11       Impact factor: 3.075

  10 in total
  4 in total

1.  Medium term review of the ASR implant system: A single surgeon series.

Authors:  M Curtin; E Murphy; C Bryan; D Jadaan; M Jadaan; D Bergin; C G Murphy; W Curtin
Journal:  J Orthop       Date:  2017-02-03

2.  Revision of ASR hip arthroplasty: analysis of two hundred and ninety six recalled patients at seven years.

Authors:  Giovanni Benelli; Merildo Maritato; Pierpaolo Cerulli Mariani; Francesco Sasso
Journal:  Int Orthop       Date:  2018-09-07       Impact factor: 3.075

3.  CORR Insights(®): Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?

Authors:  Alexander Jaime Grübl
Journal:  Clin Orthop Relat Res       Date:  2016-05-31       Impact factor: 4.176

4.  Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  Sang-Hyun Park; Zhen Lu; Robert S Hastings; Patricia A Campbell; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.