Evaluation of factors influencing the remaining astigmatism after toric intraocular lens implantation.

Nino Hirnschall, Peter C Hoffmann, Petra Draschl, Sophie Maedel, Oliver Findl.   

Abstract

PURPOSE: To evaluate the influencing factors on remaining astigmatism after implanting a toric intraocular lens during cataract surgery.
METHODS: In this observational study, consecutive patients with cataract from three different centers who received toric intraocular lenses were included. Keratometry was performed with an optical biometry device preoperatively. The IOLMaster 500 (Carl Zeiss Meditec AG, Jena, Germany) was used in Vienna, Lenstar (Haag-Streit, Köniz, Switzerland) in Castrop-Rauxel, and IOLMaster (Carl Zeiss Meditec AG) in London. Partial least squares regression was used to detect the influence of different parameters on remaining astigmatism.
RESULTS: In total, 235 eyes of 200 patients were included. Mean corneal astigmatism measured preoperatively with the optical biometry device was -2.24 ± 0.87 diopters (D) (range: -5.75 to -1.00 D). Mean absolute and vector difference between the aimed for and the postoperatively measured astigmatism were 0.48 ± 0.37 D (range: 0.00 to 2.05 D) and 0.73 ± 0.46 D (range: 0.031 to -2.20 D), respectively (P = .576). Partial least squares regression showed a significant effect of preoperatively measured corneal astigmatism and deviation between preoperative measurements of the cornea on the postoperative (unintended) remaining astigmatism.
CONCLUSIONS: The main source of error when using toric intraocular lenses is the preoperative measurement of corneal astigmatism, especially in eyes with low astigmatism. The influence of the postoperative anterior chamber depth on the cylindrical power of toric intraocular lenses and the effect of misalignment on the reduction of the astigmatism-reducing effect can be easily calculated. Copyright 2014, SLACK Incorporated.

Entities:  

Mesh:

Year:  2014        PMID: 24816207     DOI: 10.3928/1081597X-20140429-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  14 in total

1.  Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up.

Authors:  Balázs Gyöngyössy; Paul Jirak; Ulrich Schönherr
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

2.  Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens.

Authors:  Antoine Levron; Hussam El Chehab; Emilie Agard; Roman Chudzinski; Jeremy Billant; Corinne Dot
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-15       Impact factor: 3.117

3.  Accuracy of two devices and three different calculation methods for predicting residual astigmatism after intraocular lens implantation.

Authors:  Kendall Bicknell; Christopher Helpert; Kourtney Dwyer; Brett McKnight; Sonali Singh; Samuel Fulcher; Derrick Fung
Journal:  Proc (Bayl Univ Med Cent)       Date:  2020-03-03

4.  Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power.

Authors:  C Kern; L El Kaissi; K Kortuem; M Shajari; E Vounotrypidis; A Langenbucher; S Priglinger; W J Mayer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-20       Impact factor: 3.117

5.  Toric intraocular lens orientation and residual refractive astigmatism: an analysis.

Authors:  Rick Potvin; Brent A Kramer; David R Hardten; John P Berdahl
Journal:  Clin Ophthalmol       Date:  2016-09-20

6.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

7.  Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens.

Authors:  Filomena J Ribeiro; Tiago B Ferreira; Catarina Relha; Carina Esteves; Sylvia Gaspar
Journal:  Clin Ophthalmol       Date:  2019-08-29

8.  Type of residual astigmatism and uncorrected visual acuity in pseudophakic eyes.

Authors:  Yumi Hasegawa; Masato Honbo; Kazunori Miyata; Tetsuro Oshika
Journal:  Sci Rep       Date:  2022-01-24       Impact factor: 4.379

9.  The Effect of Toric Intraocular Lens Implantation in Irregular Corneal Steep and Flat Meridian.

Authors:  Ho Sik Hwang; Hyun Seung Kim; Man Soo Kim; Eun Chul Kim
Journal:  J Ophthalmol       Date:  2021-11-05       Impact factor: 1.909

10.  Comparison of Two Toric IOL Calculation Methods.

Authors:  C Kern; K Kortüm; M Müller; A Kampik; S Priglinger; W J Mayer
Journal:  J Ophthalmol       Date:  2018-01-10       Impact factor: 1.909