Literature DB >> 2480002

A method for preparing and staining histological sections containing titanium implants for light microscopy.

K Gotfredsen1, E Budtz-Jörgensen, L N Jensen.   

Abstract

An improved method for preparing and staining ground tissue-implant sections for light microscopy is presented. Undecalcified tissue blocks with titanium implants were dehydrated in an ascending series of ethanol and stained in toto with basic fuchsin. Specimens were infiltrated and embedded in methyl methacrylate and sections were prepared using a cutting-grinding-system. The polished surface was counterstained with light green or anilin blue. Light polymerizing resin was used as slide mounting medium and for mounting the coverglass. The sections obtained were 10-15 microns thick with tissue architecture which clearly differentiated structures at the tissue-implant interface. The method was very useful for computer assisted morphometric analysis.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2480002     DOI: 10.3109/10520298909106984

Source DB:  PubMed          Journal:  Stain Technol        ISSN: 0038-9153


  15 in total

1.  Topical bisphosphonate augments fixation of bone-grafted hydroxyapatite coated implants, BMP-2 causes resorption-based decrease in bone.

Authors:  Jorgen Baas; Marianne Vestermark; Thomas Jensen; Joan Bechtold; Kjeld Soballe; Thomas Jakobsen
Journal:  Bone       Date:  2017-01-07       Impact factor: 4.398

2.  No effect of platelet-rich plasma with frozen or processed bone allograft around noncemented implants.

Authors:  T B Jensen; O Rahbek; S Overgaard; K Søballe
Journal:  Int Orthop       Date:  2005-02-01       Impact factor: 3.075

3.  Particle migration and gap healing around trabecular metal implants.

Authors:  O Rahbek; S Kold; B Zippor; S Overgaard; K Søballe
Journal:  Int Orthop       Date:  2005-08-31       Impact factor: 3.075

4.  The combined effect of parathyroid hormone and bone graft on implant fixation.

Authors:  H Daugaard; B Elmengaard; T T Andreassen; J Baas; J E Bechtold; K Soballe
Journal:  J Bone Joint Surg Br       Date:  2011-01

5.  Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

Authors:  Brian Elmengaard; Joergen Baas; Thomas Jakobsen; Soren Kold; Thomas B Jensen; Joan E Bechtold; Kjeld Soballe
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

6.  The effect on bone growth enhancement of implant coatings with hydroxyapatite and collagen deposited electrochemically and by plasma spray.

Authors:  Henrik Daugaard; Brian Elmengaard; Joan E Bechtold; Thomas Jensen; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2010-03-01       Impact factor: 4.396

7.  Fixation of hydroxyapatite-coated revision implants is improved by the surgical technique of cracking the sclerotic bone rim.

Authors:  Brian Elmengaard; Joan E Bechtold; Xinqian Chen; Kjeld Søballe
Journal:  J Orthop Res       Date:  2009-08       Impact factor: 3.494

8.  Assessment of modified gold surfaced titanium implants on skeletal fixation.

Authors:  Kasra Zainali; Gorm Danscher; Thomas Jakobsen; Jorgen Baas; Per Møller; Joan E Bechtold; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2012-07-30       Impact factor: 4.396

9.  No effect of autologous growth factors (AGF) around ungrafted loaded implants in dogs.

Authors:  Thomas Bo Jensen; J E Bechtold; X Chen; M Vestermark; K Søballe
Journal:  Int Orthop       Date:  2009-10-25       Impact factor: 3.075

10.  Local bisphosphonate treatment increases fixation of hydroxyapatite-coated implants inserted with bone compaction.

Authors:  Thomas Jakobsen; Jørgen Baas; Søren Kold; Joan E Bechtold; Brian Elmengaard; Kjeld Søballe
Journal:  J Orthop Res       Date:  2009-02       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.