Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial.

O Gøthesen1, B Espehaug, L I Havelin, G Petursson, G Hallan, E Strøm, G Dyrhovden, O Furnes.   

Abstract

We performed a randomised controlled trial comparing computer-assisted surgery (CAS) with conventional surgery (CONV) in total knee replacement (TKR). Between 2009 and 2011 a total of 192 patients with a mean age of 68 years (55 to 85) with osteoarthritis or arthritic disease of the knee were recruited from four Norwegian hospitals. At three months follow-up, functional results were marginally better for the CAS group. Mean differences (MD) in favour of CAS were found for the Knee Society function score (MD: 5.9, 95% confidence interval (CI) 0.3 to 11.4, p = 0.039), the Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales for 'pain' (MD: 7.7, 95% CI 1.7 to 13.6, p = 0.012), 'sports' (MD: 13.5, 95% CI 5.6 to 21.4, p = 0.001) and 'quality of life' (MD: 7.2, 95% CI 0.1 to 14.3, p = 0.046). At one-year follow-up, differences favouring CAS were found for KOOS 'sports' (MD: 11.0, 95% CI 3.0 to 19.0, p = 0.007) and KOOS 'symptoms' (MD: 6.7, 95% CI 0.5 to 13.0, p = 0.035). The use of CAS resulted in fewer outliers in frontal alignment (> 3° malalignment), both for the entire TKR (37.9% vs. 17.9%, p = 0.042) and for the tibial component separately (28.4% vs 6.3%, p = 0.002). Tibial slope was better achieved with CAS (58.9% vs. 26.3%, p < 0.001). Operation time was 20 minutes longer with CAS. In conclusion, functional results were, statistically, marginally in favour of CAS. Also, CAS was more predictable than CONV for mechanical alignment and positioning of the prosthesis. However, the long-term outcomes must be further investigated.

Entities:  

Keywords:  Alignment; Arthroplasty; Computer assisted surgery; Computer navigation; Function; Randomised controlled trial; Total knee replacement

Mesh:

Year:  2014        PMID: 24788494     DOI: 10.1302/0301-620X.96B5.32516

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  20 in total

1.  Pinless navigation in total knee arthroplasty: navigation reduced by the maximum?

Authors:  Günther Maderbacher; Jens Schaumburger; Armin Keshmiri; Magdalena Barthel; Hans-Robert Springorum; Benjamin Craiovan; Joachim Grifka; Clemens Baier
Journal:  Int Orthop       Date:  2014-09-23       Impact factor: 3.075

2.  [Total knee arthroplasty with 3D printing technique versus conventional surgery: comparison of the outcomes].

Authors:  Ming Niu; Fei Ma; Ju-Rong Ma; Jun-Wei Li; Xu-Nian Wu; Tong Wang; Yu-Liang Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-11-20

3.  Robotic versus conventional primary total knee arthroplasty: clinical and radiological long-term results with a minimum follow-up of ten years.

Authors:  Kyu-Jin Cho; Jong-Keun Seon; Won-Young Jang; Chun-Gon Park; Eun-Kyoo Song
Journal:  Int Orthop       Date:  2018-11-19       Impact factor: 3.075

4.  Have the Causes of Revision for Total and Unicompartmental Knee Arthroplasties Changed During the Past Two Decades?

Authors:  Gro S Dyrhovden; Stein Håkon L Lygre; Mona Badawy; Øystein Gøthesen; Ove Furnes
Journal:  Clin Orthop Relat Res       Date:  2017-03-15       Impact factor: 4.176

5.  Staging Bilateral Total Knee Arthroplasties Reduces Alignment Outliers.

Authors:  Matthew A Follett; Prerna Arora; William J Maloney; Stuart B Goodman; James I Huddleston; Derek F Amanatullah
Journal:  J Arthroplasty       Date:  2022-01-10       Impact factor: 4.757

6.  Patient-specific and intra-operatively modifiable factors assessed by computer navigation predict maximal knee flexion one year after TKA.

Authors:  Frank Lampe; Carlos J Marques; Franziska Fiedler; Anusch Sufi-Siavach; Ana I Carita; Georg Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-29       Impact factor: 4.342

7.  Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial.

Authors:  Chun Hoi Yan; Kwong Yuen Chiu; Fu Yuen Ng; Ping Keung Chan; Christian Xinshuo Fang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-13       Impact factor: 4.342

8.  Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group.

Authors:  P Bollars; A Boeckxstaens; J Mievis; S Kalaai; M G M Schotanus; D Janssen
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-16

9.  Promising early outcomes of a novel anatomic knee system.

Authors:  Vincent P Galea; Mina A Botros; Rami Madanat; Christian S Nielsen; Charles Bragdon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-25       Impact factor: 4.342

10.  No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores.

Authors:  Carlos J Marques; Sandra Daniel; Anusch Sufi-Siavach; Frank Lampe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-15       Impact factor: 4.342