Literature DB >> 24786346

Three-dimensional finite element analysis of Aramany Class IV obturator prosthesis with different clasp designs.

Hideaki Hase1, Akikazu Shinya, Daiichiro Yokoyama, Akiyoshi Shinya, Yutaka Takahashi.   

Abstract

The purpose of this study was to evaluate the stress distribution on the alveolar bone surrounding abutment teeth and the displacement of the Aramany Class IV obturator prosthesis with two different clasp designs. Three-dimensional finite element models of an Aramany Class IV maxillary defect were constructed. Two different clasp designs on an obturator prosthesis (double Akers clasps and multiple Roach clasps) and two different load conditions (vertical and horizontal) were compared. Finite element analysis was used to calculate the equivalent stress. The difference in the clasp design of the Aramany Class IV obturator prosthesis affected the stress distribution of the alveolar bone surrounding the abutment teeth and the displacement of the obturator prosthesis. Multiple Roach clasps reduced the stress distribution on the alveolar bone surrounding the abutment teeth and the displacement of the Aramany Class IV obturator prosthesis compared to double Akers clasps.

Entities:  

Mesh:

Year:  2014        PMID: 24786346     DOI: 10.4012/dmj.2014-015

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  4 in total

1.  Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Authors:  Jie Lin; Zhiqiang Zheng; Akikazu Shinya; Jukka Pekka Matinlinna; Michael George Botelho; Akiyoshi Shinya
Journal:  Odontology       Date:  2014-09-09       Impact factor: 2.634

2.  Biomechanical Stress in Obturator Prostheses: A Systematic Review of Finite Element Studies.

Authors:  Mohammed A Mousa; Johari Yap Abdullah; Nafij B Jamayet; Mohammad Khursheed Alam; Adam Husein
Journal:  Biomed Res Int       Date:  2021-08-16       Impact factor: 3.411

3.  Finite element analysis of displacement with single and two piece hollow bulb obturator prosthesis.

Authors:  K V Anitha; N Gopi Chander; V Karthikeyan; Ram Hariharasudan
Journal:  Med J Armed Forces India       Date:  2018-04-09

4.  Stress distribution & deflection in an Aramany class II obturator fabricated with cobalt-chromium & titanium alloys - 3D FEA.

Authors:  Takshil D Shah; Y G Naveen; Puttaraj Kattimani; Giridhar Kamath; Kalind Shah; Aasif Raza
Journal:  Saudi Dent J       Date:  2019-01-18
  4 in total