Literature DB >> 24782364

Radiation reduction in pediatric and adult congenital patients during cardiac catheterization.

Daniel A Mauriello1, Kenneth A Fetterly, Ryan J Lennon, Guy S Reeder, Nathaniel W Taggart, Donald J Hagler, Frank Cetta, Allison K Cabalka.   

Abstract

OBJECTIVES: Our objective was to determine if technical changes combined with radiation safety initiatives reduced the radiation dose delivered to patients during congenital catheterization.
BACKGROUND: Use of ionizing radiation is necessary during cardiac catheterization. Minimizing radiation dose, while maintaining clinically useful image quality, is an important safety issue. In our congenital heart center intentional practice changes, including technical changes and provider awareness initiatives, were implemented to decrease radiation dose.
METHODS: Data were retrospectively collected for all procedures involving children and adults with congenital heart disease (CHD) undergoing catheterization over 45 months. Cases were divided into three categories including: noninterventional (NI), simple intervention (SI), and complex intervention (CI). The change in dose was modeled as log of cumulative air kerma (Ka,r ). The change in Ka,r was evaluated for each procedural category as well as changes occurring as a function of age and weight.
RESULTS: Considering all procedures (n = 1,082), Ka,r decreased by 61%. In the NI group (n = 481), Ka,r decreased by 71%. In the SI group (n = 424), Ka,r decreased by 74%. The Ka,r for the 10-17 year old group (n = 125) and those ≥18 years (n = 709) decreased 74 and 67%, respectively. The Ka,r decreased 72 and 66% for those 20-60 kg and ≥60 kg, respectively. Groups not showing significant change in Ka,r included CI, age ≤9 years, and weight ≤20 kg.
CONCLUSIONS: Through technical changes and provider awareness initiatives, our institution dramatically reduced the radiation dose in the majority of pediatric and adult CHD patients undergoing cardiac catheterization.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  children; congenital heart disease; interventional catheterization

Mesh:

Year:  2014        PMID: 24782364     DOI: 10.1002/ccd.25533

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  5 in total

Review 1.  [Hybrid operating theater].

Authors:  T Fuchs-Buder; N Settembre; D Schmartz
Journal:  Anaesthesist       Date:  2018-07       Impact factor: 1.041

2.  Reducing Fluoroscopic Radiation Exposure During Endomyocardial Biopsy in Pediatric Transplant Recipients.

Authors:  Jeffrey G Gossett; Christina L Sammet; Anya Agrawal; Karen Rychlik; David F Wax
Journal:  Pediatr Cardiol       Date:  2016-11-23       Impact factor: 1.655

3.  Radiation Reduction Capabilities of a Next-Generation Pediatric Imaging Platform.

Authors:  Luke J Lamers; Martine Moran; Jenna N Torgeson; John S Hokanson
Journal:  Pediatr Cardiol       Date:  2015-07-28       Impact factor: 1.655

4.  Choice of tube extremity for emission of the lowest radiation dose in pediatric patients.

Authors:  Guilherme Oberto Rodrigues; Rogério Fachel Medeiros; Sergio Chaves Rodrigues; Liliana Fortini Cavalheiro Boll; Maria Claudia Irigoyen; Silvia Goldmeier
Journal:  Int J Cardiol Heart Vasc       Date:  2018-10-10

5.  Comparison of skin dose measurement using nanoDot® dosimeter and machine readings of radiation dose during cardiac catheterization in children.

Authors:  Duraisamy Balaguru; Matthew Rodriguez; Stephanie Leon; Louis K Wagner; Charles W Beasley; Andrew Sultzer; Mohammed T Numan
Journal:  Ann Pediatr Cardiol       Date:  2018 Jan-Apr
  5 in total