Literature DB >> 24756892

Prospective comparative study between straight and curved probe for pedicle screw insertion.

Yogesh K Pithwa1, Kumar Venkatesh.   

Abstract

PURPOSE: To evaluate difference in accuracy of pedicle screw insertion in thoracic and lumbosacral spine using a straight pedicle probe vis-à-vis a curved one.
METHODS: Prospective, comparative, non-randomized, single-blind study. Straight and curved pedicle probes used on opposite sides of same vertebra in patients undergoing thoracolumbar pedicle screw fixation for various indications. Postoperative blinded evaluation for pedicle breaches done with a CT scan. Pedicle breaches graded as grade 0: no breach, grade 1: <2 mm, grade 2: 2-4 mm and grade 3: >4 mm breach.
RESULTS: After appropriate statistical power analysis, 300 screws inserted in 59 patients from T4-L5 levels. No significant differences noted between the two probes in terms of screw length [two-tailed p = 0.16]; grade 0 screws [two-tailed p = 0.49] or screws with grade 2/3 breaches [two-tailed p = 0.68]. With the right-hand-dominant operating-surgeon standing to left of patient during surgery, no difference noted between the two probes for either the right or left-side pedicle screw insertion [two-tailed p = 1]. Repeating these tests in the subset of thoracic pedicle screws too, revealed no significant difference.
CONCLUSIONS: No significant difference in outcome of pedicle screw insertion with either a straight or a curved pedicle probe.

Entities:  

Mesh:

Year:  2014        PMID: 24756892     DOI: 10.1007/s00586-014-3310-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  11 in total

Review 1.  Multisection CT: scanning techniques and clinical applications.

Authors:  J Rydberg; K A Buckwalter; K S Caldemeyer; M D Phillips; D J Conces; A M Aisen; S A Persohn; K K Kopecky
Journal:  Radiographics       Date:  2000 Nov-Dec       Impact factor: 5.333

2.  Morphometric study of the thoracic vertebral pedicle in an Indian population.

Authors:  Sandeep P Datir; Sajal R Mitra
Journal:  Spine (Phila Pa 1976)       Date:  2004-06-01       Impact factor: 3.468

3.  Computed tomographic morphometry of thoracic pedicles: safety margin of transpedicular screw fixation in malaysian malay population.

Authors:  Kai Ming Liau; Mohd Imran Yusof; Mohd Shafie Abdullah; Sarimah Abdullah; Abdul Halim Yusof
Journal:  Spine (Phila Pa 1976)       Date:  2006-07-15       Impact factor: 3.468

4.  The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae.

Authors:  Masashi Neo; Takeshi Sakamoto; Shunsuke Fujibayashi; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2005-12-15       Impact factor: 3.468

5.  Morphological comparison between adolescent and adult lumbar pedicles using computerised tomography scanning.

Authors:  Abdullah Mohammed Abdo Mughir; Mohd Imran Yusof; Shafie Abdullah; Shahrulazua Ahmad
Journal:  Surg Radiol Anat       Date:  2010-01-03       Impact factor: 1.246

6.  Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe?

Authors:  Levent Karapinar; Nuri Erel; Hasan Ozturk; Taskin Altay; Ahmet Kaya
Journal:  J Spinal Disord Tech       Date:  2008-02

7.  The learning curve of pedicle screw placement: how many screws are enough?

Authors:  Augusto Gonzalvo; Gregory Fitt; Susan Liew; David de la Harpe; Peter Turner; Lu Ton; Myron A Rogers; Peter H Wilde
Journal:  Spine (Phila Pa 1976)       Date:  2009-10-01       Impact factor: 3.468

8.  Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction.

Authors:  Ulf R Liljenqvist; Thomas Allkemper; Lars Hackenberg; Thomas M Link; Jörn Steinbeck; Henry F H Halm
Journal:  J Bone Joint Surg Am       Date:  2002-03       Impact factor: 5.284

9.  Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Orthop Clin North Am       Date:  1986-01       Impact factor: 2.472

10.  Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.

Authors:  Hitesh N Modi; Seung Woo Suh; Harry Fernandez; Jae Hyuk Yang; Hae-Ryong Song
Journal:  Eur Spine J       Date:  2008-10-01       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.