Literature DB >> 11112829

Multisection CT: scanning techniques and clinical applications.

J Rydberg1, K A Buckwalter, K S Caldemeyer, M D Phillips, D J Conces, A M Aisen, S A Persohn, K K Kopecky.   

Abstract

Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section-capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.

Entities:  

Mesh:

Year:  2000        PMID: 11112829     DOI: 10.1148/radiographics.20.6.g00nv071787

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  55 in total

1.  Strategies of dose reduction.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2002-03-07

Review 2.  Imaging of aortic dissection by helical computed tomography (CT).

Authors:  Serge Willoteaux; Christophe Lions; Virginia Gaxotte; Ziad Negaiwi; J P Beregi
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

3.  Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study.

Authors:  G Brix; U Lechel; R Veit; R Truckenbrodt; G Stamm; E M Coppenrath; J Griebel; H-D Nagel
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

Review 4.  Optimizing technique for multi-slice CT.

Authors:  Sanjay Saini; Roy V Dsouza
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 5.  Multi-detector computed tomography imaging of large airway pathology: A pictorial review.

Authors:  Tejeshwar Singh Jugpal; Anju Garg; Gulshan Rai Sethi; Mradul Kumar Daga; Jyoti Kumar
Journal:  World J Radiol       Date:  2015-12-28

6.  The utility of head computed tomography in the emergency department evaluation of syncope.

Authors:  Nikhil Goyal; Michael W Donnino; Ravi Vachhani; Ravi Bajwa; Tabassum Ahmad; Ronny Otero
Journal:  Intern Emerg Med       Date:  2006       Impact factor: 3.397

7.  Multidetector-row computed tomography diagnosis of small bowel obstruction: can coronal reformations replace axial images?

Authors:  Vahid Yaghmai; Paul Nikolaidis; Nancy A Hammond; Bojan Petrovic; Richard M Gore; Frank H Miller
Journal:  Emerg Radiol       Date:  2006-08-29

8.  Diagnostic value of pelvic radiography in the initial trauma series in blunt trauma.

Authors:  Micael E A Their; Frank V Bensch; Seppo K Koskinen; Lauri Handolin; Martti J Kiuru
Journal:  Eur Radiol       Date:  2005-01-19       Impact factor: 5.315

Review 9.  [Multislice computed tomographic myelography].

Authors:  R Klingebiel; F Masuhr; P Rogalla; E Hein; R Juran; H C Bauknecht; G Bohner
Journal:  Nervenarzt       Date:  2006-02       Impact factor: 1.214

10.  Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

Authors:  J Badawi-Fayad; C Yazbeck; A Balzeau; T H Nguyen; A Istoc; D Grimaud-Hervé; E- A Cabanis
Journal:  Surg Radiol Anat       Date:  2005-10-07       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.