Literature DB >> 24752381

Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Peng Li1, Murray Johnstone2, Ruikang K Wang3.   

Abstract

We demonstrate an extended-imaging-range anterior-segment optical coherence tomography (eAS-OCT) system for the biometric assessment of full AS in human eye. This newly developed eAS-OCT operating at 1340-nm wavelength band is simultaneously capable of an imaging speed of 120 kHz A-line scan rate, an axial resolution of 7.2 μm, and an extended imaging range of up to 16 mm in air. Imaging results from three healthy subjects and one subject with a narrow-angle demonstrate the instrument's utility. With this system, it can provide anatomical dimensions of AS, including central corneal thickness, anterior chamber width, anterior chamber depth, crystalline lens vault, crystalline lens thickness, angle opening distance (AOD500/AOD750), and the area described by the trabecular-iris space (TISA500/TISA750) at 500/750  μm. We also use eAS-OCT to image and quantify dynamic functional changes of the AS in response to a light stimulus that induces physiological pupillary changes as well as accommodative efforts that induce lens changes. The results show that the described eAS-OCT is able to provide full anatomical biometry for AS and is useful for the studies where the dynamic response of AS compartment to certain stimulus is required.

Entities:  

Mesh:

Year:  2014        PMID: 24752381      PMCID: PMC3993014          DOI: 10.1117/1.JBO.19.4.046013

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  56 in total

1.  Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival.

Authors:  Al-Hafeez Dhalla; Derek Nankivil; Theresa Bustamante; Anthony Kuo; Joseph A Izatt
Journal:  Opt Lett       Date:  2012-06-01       Impact factor: 3.776

2.  Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes.

Authors:  C J Pavlin; K Harasiewicz; F S Foster
Journal:  Am J Ophthalmol       Date:  1992-04-15       Impact factor: 5.258

Review 3.  Phakic intraocular lenses.

Authors:  Ladan Espandar; Jay J Meyer; Majid Moshirfar
Journal:  Curr Opin Ophthalmol       Date:  2008-07       Impact factor: 3.761

4.  Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT.

Authors:  Christopher Kai-shun Leung; Haitao Li; Robert Neal Weinreb; Jing Liu; Carol Yim Lui Cheung; Ricky Yiu Kwong Lai; Chi Pui Pang; Dennis Shun Chiu Lam
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-04-11       Impact factor: 4.799

5.  Imaging the ocular anterior segment with real-time, full-range Fourier-domain optical coherence tomography.

Authors:  Marinko V Sarunic; Sanjay Asrani; Joseph A Izatt
Journal:  Arch Ophthalmol       Date:  2008-04

6.  Analysis of anterior segment dynamics using anterior segment optical coherence tomography before and after laser peripheral iridotomy.

Authors:  Ce Zheng; Celeste P Guzman; Carol Y Cheung; Yingke He; David S Friedman; Sim-Heng Ong; Arun K Narayanaswamy; Paul T Chew; Shamira A Perera; Tin Aung
Journal:  JAMA Ophthalmol       Date:  2013-01       Impact factor: 7.389

Review 7.  Angle closure glaucoma: a mechanistic review.

Authors:  Monisha E Nongpiur; Judy Y F Ku; Tin Aung
Journal:  Curr Opin Ophthalmol       Date:  2011-03       Impact factor: 3.761

8.  Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma.

Authors:  G Marchini; A Pagliarusco; A Toscano; R Tosi; C Brunelli; L Bonomi
Journal:  Ophthalmology       Date:  1998-11       Impact factor: 12.079

9.  Value of preoperative phakic intraocular lens simulation using optical coherence tomography.

Authors:  Muriël Doors; Tos T J M Berendschot; Fred Hendrikse; Carroll A B Webers; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2009-03       Impact factor: 3.351

10.  Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch.

Authors:  Marco Ruggeri; Stephen R Uhlhorn; Carolina De Freitas; Arthur Ho; Fabrice Manns; Jean-Marie Parel
Journal:  Biomed Opt Express       Date:  2012-06-06       Impact factor: 3.732

View more
  17 in total

1.  Wide field and highly sensitive angiography based on optical coherence tomography with akinetic swept source.

Authors:  Jingjiang Xu; Shaozhen Song; Wei Wei; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2016-12-22       Impact factor: 3.732

2.  Long-range and wide field of view optical coherence tomography for in vivo 3D imaging of large volume object based on akinetic programmable swept source.

Authors:  Shaozhen Song; Jingjiang Xu; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2016-10-27       Impact factor: 3.732

3.  Platform to investigate aqueous outflow system structure and pressure-dependent motion using high-resolution spectral domain optical coherence tomography.

Authors:  Sepideh Hariri; Murray Johnstone; Yi Jiang; Steven Padilla; Zhehai Zhou; Roberto Reif; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

4.  Pulsatile motion of trabecular meshwork in a patient with iris cyst by phase-sensitive optical coherence tomography: a case report.

Authors:  Yi-Chen Sun; Peng Li; Murray Johnstone; Ruikang K Wang; Tueng T Shen
Journal:  Quant Imaging Med Surg       Date:  2015-02

5.  Anterior segment optical coherence tomography evaluation of ocular graft-versus-host disease: a case study.

Authors:  Peng Li; Yichen Sun; Sepideh Hariri; Zhehai Zhou; Yoshihiro Inamoto; Stephanie J Lee; Tueng T Shen; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2015-02

6.  Aqueous Angiography in Living Nonhuman Primates Shows Segmental, Pulsatile, and Dynamic Angiographic Aqueous Humor Outflow.

Authors:  Alex S Huang; Meng Li; Diya Yang; Huaizhou Wang; Ningli Wang; Robert N Weinreb
Journal:  Ophthalmology       Date:  2017-02-23       Impact factor: 12.079

7.  Grading Anterior Chamber Inflammation with Anterior Segment Optical Coherence Tomography: An Overview.

Authors:  Morgan Maring; Steven S Saraf; Marian Blazes; Sumit Sharma; Sunil Srivastava; Kathryn L Pepple; Cecilia S Lee
Journal:  Ocul Immunol Inflamm       Date:  2022-02-17       Impact factor: 3.728

8.  Development of fully automated anterior chamber cell analysis based on image software.

Authors:  Tae Seen Kang; Yeongseop Lee; Seongjin Lee; Kyonghoon Kim; Woong-Sub Lee; Woohyuk Lee; Jin Hyun Kim; Yong Seop Han
Journal:  Sci Rep       Date:  2021-05-21       Impact factor: 4.379

9.  Aqueous Angiography: Real-Time and Physiologic Aqueous Humor Outflow Imaging.

Authors:  Sindhu Saraswathy; James C H Tan; Fei Yu; Brian A Francis; David R Hinton; Robert N Weinreb; Alex S Huang
Journal:  PLoS One       Date:  2016-01-25       Impact factor: 3.240

10.  The disposable bandage soft contact lenses therapy and anterior segment optical coherence tomography for management of ocular graft-versus-host disease.

Authors:  Yi-Chen Sun; Yoshihiro Inamoto; Ruikang K Wang; Stephanie J Lee; Kai-Feng Hung; Tueng T Shen
Journal:  BMC Ophthalmol       Date:  2021-07-04       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.