Literature DB >> 24716531

An integrated array of microfluidic oxygenators as a neonatal lung assist device: in vitro characterization and in vivo demonstration.

Niels Rochow1, Asmaa Manan, Wen-I Wu, Gerhard Fusch, Shelley Monkman, Jennifer Leung, Emily Chan, Dipen Nagpal, Dragos Predescu, John Brash, Ponnambalam Ravi Selvaganapathy, Christoph Fusch.   

Abstract

A miniaturized oxygenator device that is perfused like an artificial placenta via the umbilical vessels may have significant potential to save the lives of newborns with respiratory insufficiency. Recently we presented the concept of an integrated modular lung assist device (LAD) that consists of stacked microfluidic single oxygenator units (SOUs) and demonstrated the technical details and operation of SOU prototypes. In this article, we present a LAD prototype that is designed to accommodate the different needs of term and preterm infants by permitting changing of the number of parallel-stacked microfluidic SOUs according to the actual body weight. The SOUs are made of polydimethylsiloxane, arranged in parallel, and connected though 3D-printed polymeric interconnects to form the LAD. The flow characteristics and the gas exchange properties were tested in vitro using human blood. We found that the pressure drop of the LAD increased linearly with flow rate. Gas exchange rates of 2.4-3.8 μL/min/cm(2) (0.3-0.5 mL/kg/min) and 6.4-10.1 μL/min/cm(2) (0.8-1.3 mL/kg/min) for O2 and CO2 , respectively, were achieved. We also investigated protein adsorption to provide preliminary information on the need for application of anticoagulant coating of LAD materials. Albumin adsorption, as measured by gold staining, showed that surface uptake was evenly distributed and occurred at the monolayer level (>0.2 μg/cm(2) ). Finally, we also tested the LAD under in vivo conditions using a newborn piglet model (body weight 1.65-2.0 kg). First, the effect of an arteriovenous bypass via a carotid artery-to-jugular vein shortcut on heart rate and blood pressure was investigated. Heart rate and mean arterial blood pressure remained stable for extracorporeal flow rates of up to 61 mL/kg/min (101 mL/min). Next, the LAD was connected to umbilical vessels (maximum flow rate of 24 mL/min [10.4 mL/kg/min]), and O2 gas exchange was measured under hypoxic conditions (Fi O2  = 0.15) and was found to be 3.0 μL/min/cm(2) . These results are encouraging and support the feasibility of an artificial placental design for an LAD.
Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Artificial placenta; Catheter; Gas exchange; Hemocompatibility; Lung assist device; Newborn; Polydimethylsiloxane; Respiratory distress; Respiratory insufficiency; Umbilical vessel

Mesh:

Year:  2014        PMID: 24716531     DOI: 10.1111/aor.12269

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  11 in total

1.  Bioreactor Development for Lung Tissue Engineering.

Authors:  Angela Panoskaltsis-Mortari
Journal:  Curr Transplant Rep       Date:  2015-03

2.  Development of a biomimetic microfluidic oxygen transfer device.

Authors:  A A Gimbel; E Flores; A Koo; G García-Cardeña; J T Borenstein
Journal:  Lab Chip       Date:  2016-08-16       Impact factor: 6.799

3.  A small-scale, rolled-membrane microfluidic artificial lung designed towards future large area manufacturing.

Authors:  A J Thompson; L H Marks; M J Goudie; A Rojas-Pena; H Handa; J A Potkay
Journal:  Biomicrofluidics       Date:  2017-04-05       Impact factor: 2.800

4.  An ultra-thin, all PDMS-based microfluidic lung assist device with high oxygenation capacity.

Authors:  Mohammadhossein Dabaghi; Neda Saraei; Gerhard Fusch; Niels Rochow; John L Brash; Christoph Fusch; P Ravi Selvaganapathy
Journal:  Biomicrofluidics       Date:  2019-06-27       Impact factor: 2.800

5.  Modeling the effect of blood vessel bifurcation ratio on occlusive thrombus formation.

Authors:  Hari Hara Sudhan Lakshmanan; Joseph J Shatzel; Sven R Olson; Owen J T McCarty; Jeevan Maddala
Journal:  Comput Methods Biomech Biomed Engin       Date:  2019-05-08       Impact factor: 1.763

6.  Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange.

Authors:  Harpreet Matharoo; Mohammadhossein Dabaghi; Niels Rochow; Gerhard Fusch; Neda Saraei; Mohammed Tauhiduzzaman; Stephen Veldhuis; John Brash; Christoph Fusch; P Ravi Selvaganapathy
Journal:  Biomicrofluidics       Date:  2018-01-11       Impact factor: 2.800

Review 7.  Management of hypoxemic respiratory failure and pulmonary hypertension in preterm infants.

Authors:  N Ambalavanan; J L Aschner
Journal:  J Perinatol       Date:  2016-06       Impact factor: 2.521

Review 8.  Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering.

Authors:  Ana Rubina Perestrelo; Ana C P Águas; Alberto Rainer; Giancarlo Forte
Journal:  Sensors (Basel)       Date:  2015-12-10       Impact factor: 3.576

9.  Comment on "A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress".

Authors:  Li Wang; Fang Li; Zhichun Feng; Yuan Shi
Journal:  Adv Sci (Weinh)       Date:  2021-05-03       Impact factor: 16.806

10.  A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress.

Authors:  Mohammadhossein Dabaghi; Niels Rochow; Neda Saraei; Gerhard Fusch; Shelley Monkman; Kevin Da; Alireza Shahin-Shamsabadi; John L Brash; Dragos Predescu; Kathleen Delaney; Christoph Fusch; P Ravi Selvaganapathy
Journal:  Adv Sci (Weinh)       Date:  2020-09-29       Impact factor: 16.806

View more