Literature DB >> 24713466

Accuracy and reliability of measurements obtained from computed tomography 3D volume rendered images.

Kyra E Stull1, Meredith L Tise2, Zabiullah Ali3, David R Fowler4.   

Abstract

Forensic pathologists commonly use computed tomography (CT) images to assist in determining the cause and manner of death as well as for mass disaster operations. Even though the design of the CT machine does not inherently produce distortion, most techniques within anthropology rely on metric variables, thus concern exists regarding the accuracy of CT images reflecting an object's true dimensions. Numerous researchers have attempted to validate the use of CT images, however the comparisons have only been conducted on limited elements and/or comparisons were between measurements taken from a dry element and measurements taken from the 3D-CT image of the same dry element. A full-body CT scan was performed prior to autopsy at the Office of the Chief Medical Examiner for the State of Maryland. Following autopsy, the remains were processed to remove all soft tissues and the skeletal elements were subject to an additional CT scan. Percent differences and Bland-Altman plots were used to assess the accuracy between osteometric variables obtained from the dry skeletal elements and from CT images with and without soft tissues. An additional seven crania were scanned, measured by three observers, and the reliability was evaluated by technical error of measurement (TEM) and relative technical error of measurement (%TEM). Average percent differences between the measurements obtained from the three data sources ranged from 1.4% to 2.9%. Bland-Altman plots illustrated the two sets of measurements were generally within 2mm for each comparison between data sources. Intra-observer TEM and %TEM for three observers and all craniometric variables ranged between 0.46mm and 0.77mm and 0.56% and 1.06%, respectively. The three-way inter-observer TEM and %TEM for craniometric variables was 2.6mm and 2.26%, respectively. Variables that yielded high error rates were orbital height, orbital breadth, inter-orbital breadth and parietal chord. Overall, minimal differences were found among the data sources and high accuracy was noted between the observers, which prove CT images are an acceptable source to collect osteometric variables.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Bland–Altman; Measurement error; Percent differences; Reliability; Technical error of measurement

Mesh:

Year:  2014        PMID: 24713466     DOI: 10.1016/j.forsciint.2014.03.005

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  21 in total

1.  Optic Strut and Para-clinoid Region - Assessment by Multi-detector Computed Tomography with Multiplanar and 3 Dimensional Reconstructions.

Authors:  K Suprasanna; S R Ravikiran; Ashvini Kumar; Channabasappa Chavadi; Sanyal Pulastya
Journal:  J Clin Diagn Res       Date:  2015-10-01

2.  Shape morphing technique can accurately predict pelvic bone landmarks.

Authors:  Michal Kuchař; Petr Henyš; Pavel Rejtar; Petr Hájek
Journal:  Int J Legal Med       Date:  2021-01-27       Impact factor: 2.686

3.  Stability of upper face sexual dimorphism in central European populations (Czech Republic) during the modern age.

Authors:  Šárka Bejdová; Ján Dupej; Václav Krajíček; Jana Velemínská; Petr Velemínský
Journal:  Int J Legal Med       Date:  2017-06-21       Impact factor: 2.686

4.  Estimation of stature from femur length measured using computed tomography after the analysis of three-dimensional characteristics of femur bone in Korean cadavers.

Authors:  Sookyoung Lee; Ho-Hyeon Gong; Jin-Young Hyun; Hyung-Nam Koo; Han-Young Lee; Nak-Eun Chung; Young-Shik Choi; Kyung-Moo Yang; Byung Ha Choi
Journal:  Int J Legal Med       Date:  2017-02-20       Impact factor: 2.686

5.  Disregarding population specificity: its influence on the sex assessment methods from the tibia.

Authors:  Anežka Kotěrová; Jana Velemínská; Ján Dupej; Hana Brzobohatá; Aleš Pilný; Jaroslav Brůžek
Journal:  Int J Legal Med       Date:  2016-07-20       Impact factor: 2.686

6.  Machine learning approaches for sex estimation using cranial measurements.

Authors:  Diana Toneva; Silviya Nikolova; Gennady Agre; Dora Zlatareva; Vassil Hadjidekov; Nikolai Lazarov
Journal:  Int J Legal Med       Date:  2020-11-11       Impact factor: 2.686

7.  Sex determination of a Tunisian population by CT scan analysis of the skull.

Authors:  Malek Zaafrane; Mehdi Ben Khelil; Ines Naccache; Ekbel Ezzedine; Frédéric Savall; Norbert Telmon; Najla Mnif; Moncef Hamdoun
Journal:  Int J Legal Med       Date:  2017-09-21       Impact factor: 2.686

8.  Inter- and intra-scan variability for lung imaging quantifications via CT.

Authors:  Sachin S Shankar; Eric A Hoffman; Jarron Atha; Jessica C Sieren; Ehsan Samei; Ehsan Abadi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

9.  Virtual CT morphometry of lower limb long bones for estimation of the sex and stature using postmortem Japanese adult data in forensic identification.

Authors:  Asmaa Mohammed Hishmat; Tomomi Michiue; Nozomi Sogawa; Shigeki Oritani; Takaki Ishikawa; Irene Atef Fawzy; Mohamed Abdel Mohsen Hashem; Hitoshi Maeda
Journal:  Int J Legal Med       Date:  2015-07-09       Impact factor: 2.686

10.  Three dimensional modeling and quantitative analysis of long bone parameters of rabbit using micro-computed tomography.

Authors:  C Bakici; R O Akgun; O Ekim; B Batur; M Bakici; D Ozen; C Soydal
Journal:  Iran J Vet Res       Date:  2021       Impact factor: 1.376

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.