Literature DB >> 24703216

A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements.

Tomàs Guinovart1, Gastón A Crespo2, F Xavier Rius1, Francisco J Andrade3.   

Abstract

A new solid-state reference electrode using a polymeric membrane of polyvinyl butyral (PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented. The electrode is made by drop-casting the membrane cocktail onto a glassy carbon (GC) substrate. A stable potential (less than 1 mV dec(-1)) over a wide range of concentrations for the several chemical species tested is obtained. No significant influence to changes in redox potential, light and pH are observed. The response of this novel electrode shows good correlation when compared with a conventional double-junction reference electrode. Also good long-term stability (90±33 μV/h) and a lifetime of approximately 4 months are obtained. Aspects related to the working mechanisms are discussed. Atomic Force Microscopy (AFM) studies reveal the presence of nanopores and channels on the surface, and electrochemical impedance spectroscopy (EIS) of optimized electrodes show low bulk resistances, usually in the kΩ range, suggesting that a nanoporous polymeric structure is formed in the interface with the solution. Future applications of this electrode as a disposable device for decentralized measurements are discussed. Examples of the utilization on wearable substrates (tattoos, fabrics, etc) are provided.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Decentralized measurements; Reference electrode; Solid-contact potentiometric sensors

Year:  2014        PMID: 24703216     DOI: 10.1016/j.aca.2014.02.028

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  13 in total

Review 1.  Recent progress in the development of improved reference electrodes for electrochemistry.

Authors:  Blair K Troudt; Celeste R Rousseau; Xin I N Dong; Evan L Anderson; Philippe Bühlmann
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

2.  Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.

Authors:  Wei Gao; Sam Emaminejad; Hnin Yin Yin Nyein; Samyuktha Challa; Kevin Chen; Austin Peck; Hossain M Fahad; Hiroki Ota; Hiroshi Shiraki; Daisuke Kiriya; Der-Hsien Lien; George A Brooks; Ronald W Davis; Ali Javey
Journal:  Nature       Date:  2016-01-28       Impact factor: 49.962

3.  Microfluidic-based ion-selective thermoplastic electrode array for point-of-care detection of potassium and sodium ions.

Authors:  Tugba Ozer; Charles S Henry
Journal:  Mikrochim Acta       Date:  2022-03-23       Impact factor: 5.833

4.  Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination.

Authors:  Ayman H Kamel; Abd El-Galil E Amr; Abdulrahman A Almehizia; Elsayed A Elsayed; Gaber O Moustafa
Journal:  RSC Adv       Date:  2021-08-18       Impact factor: 4.036

5.  All-Solid-State Sodium-Selective Electrode with a Solid Contact of Chitosan/Prussian Blue Nanocomposite.

Authors:  Tanushree Ghosh; Hyun-Joong Chung; Jana Rieger
Journal:  Sensors (Basel)       Date:  2017-11-03       Impact factor: 3.576

6.  RuO₂ pH Sensor with Super-Glue-Inspired Reference Electrode.

Authors:  Wade Lonsdale; Magdalena Wajrak; Kamal Alameh
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

7.  Toward In Vivo Transdermal pH Sensing with a Validated Microneedle Membrane Electrode.

Authors:  Juan José García-Guzmán; Clara Pérez-Ràfols; María Cuartero; Gastón A Crespo
Journal:  ACS Sens       Date:  2021-02-10       Impact factor: 7.711

8.  Wireless, Flexible, Ion-Selective Electrode System for Selective and Repeatable Detection of Sodium.

Authors:  Hyo-Ryoung Lim; Yun-Soung Kim; Shinjae Kwon; Musa Mahmood; Young-Tae Kwon; Yongkuk Lee; Soon Min Lee; Woon-Hong Yeo
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

9.  Sensitivity, Noise and Resolution in a BEOL-Modified Foundry-Made ISFET with Miniaturized Reference Electrode for Wearable Point-of-Care Applications.

Authors:  Francesco Bellando; Leandro Julian Mele; Pierpaolo Palestri; Junrui Zhang; Adrian Mihai Ionescu; Luca Selmi
Journal:  Sensors (Basel)       Date:  2021-03-04       Impact factor: 3.576

Review 10.  Nanomaterials for IoT Sensing Platforms and Point-of-Care Applications in South Korea.

Authors:  Seung-Ho Choi; Joon-Seok Lee; Won-Jun Choi; Jae-Woo Seo; Seon-Jin Choi
Journal:  Sensors (Basel)       Date:  2022-01-13       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.