Literature DB >> 24696221

Safety and efficacy of internal transjugular approach for transvenous extraction of implantable cardioverter defibrillator leads.

Maria Grazia Bongiorni1, Luca Segreti2, Andrea Di Cori2, Giulio Zucchelli2, Stefano Viani2, Luca Paperini2, Raffaele De Lucia2, Adriano Boem2, Dianora Levorato2, Ezio Soldati2.   

Abstract

AIMS: We report our 15 years experience of a mechanical single-sheath technique with a multiple venous entry-site approach. We evaluated the effectiveness and safety of this technique in implantable defibrillator (ICD) lead extraction and investigated the potential association between clinical and lead-related factors and procedural complexity. METHODS AND
RESULTS: The proposed technique consists of an initial attempt at manual traction, followed by mechanical dilatation performed through the venous entry-site and, if necessary, by crossover to the internal transjugular approach. The study cohort comprised 545 consecutive patients referred to our institution for transvenous lead extraction from January 1997 to December 2012. Initial manual traction resulted in the effective removal of 6% of leads. Mechanical dilatation increased the success rate to 89% when performed through the venous entry-site, and to 99% when subsequently attempted via the internal jugular vein. No major complications were associated with lead extraction. Dwell-time, a passive fixation mechanism and dual-coil lead design were independently associated with the need for mechanical dilatation. However, dwell-time was the only variable associated with crossover to the internal transjugular approach. Specifically, a dwell-time of 20 months best predicted the need for venous entry-site mechanical dilatation, while a value of 55 months predicted crossover to the internal transjugular approach.
CONCLUSION: Mechanical transvenous extraction of ICD leads is a complex but safe and effective procedure. A longer lead dwell-time is associated with the need for mechanical dilatation and for crossover to the internal transjugular approach; this should be considered when planning the removal procedure. Moreover, passive lead fixation and dual-coil lead design predict a more challenging extraction procedure. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Extraction; Implantable defibrillator; Internal jugular vein; Lead

Mesh:

Year:  2014        PMID: 24696221     DOI: 10.1093/europace/euu004

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  9 in total

Review 1.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

Review 2.  Transvenous Lead Extractions: Current Approaches and Future Trends.

Authors:  Adryan A Perez; Frank W Woo; Darren C Tsang; Roger G Carrillo
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 3.  [ICD leads].

Authors:  Carsten W Israel; Mohamed Karim Sheta
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-06

Review 4.  A Questionable Indication For ICD Extraction After Successful VT Ablation.

Authors:  Luca Segreti; Andrea Di Cori; Giulio Zucchelli; Ezio Soldati; Giovanni Coluccia; Stefano Viani; Luca Paperini; Maria Grazia Bongiorni
Journal:  J Atr Fibrillation       Date:  2015-04-30

5.  Predictors of the need for supportive femoral approach during transvenous extraction of pacemaker and defibrillator leads in Japanese patients.

Authors:  Tsuyoshi Isawa; Taku Honda; Kazuhiro Yamaya; Masataka Taguri
Journal:  J Arrhythm       Date:  2020-07-03

6.  Laser-assisted extraction of a pacing lead with a supraclavicular course.

Authors:  Daniel P Morin
Journal:  HeartRhythm Case Rep       Date:  2015-04-21

7.  Transjugular lead fragment extraction to improve tricuspid regurgitation.

Authors:  Robert D Schaller; Mouhannad M Sadek; Jeffrey J Luebbert; Jian-Fang Ren; Francis E Marchlinski
Journal:  HeartRhythm Case Rep       Date:  2015-02-13

8.  Retrieval of a transcatheter pacemaker in sheep after a mid-term implantation time.

Authors:  Maria Grazia Bongiorni; Luca Segreti; Andrea Di Cori; Matthew Bonner; Michael Eggen; Pamela Omdahl
Journal:  HeartRhythm Case Rep       Date:  2015-10-23

9.  Effectiveness and safety of transvenous extraction of single- versus dual-coil implantable cardioverter-defibrillator leads at single-center experience.

Authors:  Andrzej Ząbek; Krzysztof Boczar; Maciej Dębski; Mateusz Ulman; Roman Pfitzner; Robert Musiał; Jacek Lelakowski; Barbara Małecka
Journal:  Medicine (Baltimore)       Date:  2019-07       Impact factor: 1.817

  9 in total