Literature DB >> 24687307

Performances of capillary electrophoresis and HPLC methods in HbA1c determination: diagnostic accuracy in HbS and HbD-Iran variants' presence.

Mariarita Dessi1, Massimo Pieri, Stefano Pignalosa, Francesca Gabriela Martino, Rossella Zenobi.   

Abstract

BACKGROUND: Glycated hemoglobin (HbA1c) provides a useful estimate of mean glycemia in patients with diabetes and is directly related to risks for diabetes complications. The aim of this study is to compare a capillary electrophoresis method and two high-performance liquid chromatography (HPLC) cation-exchange analyzers (Variant II (Bio-Rad Laboratories, Inc., Hercules, CA) and G8 (Tosoh Biosciences, San Francisco, CA)) to identify the most reliable method in Hb variants' presence.
METHODS: Measurements of HbA1c were carried out in blood samples from 200 Tor Vergata Hospital patients, using G8 Tosoh, and from 107 San Filippo Neri Hospital patients, using Variant II Bio-Rad methods. All samples were analyzed by Capillarys 2 Flex Piercing (FP; Sebia, Lisses, France).
RESULTS: There was a good concordance between the results of capillary electrophoresis and HPLC methods (R(2) = 0.99, P < 0.0001 for G8 HPLC; R(2) = 0.99, P < 0.0001 for Variant II HPLC). During the study, we observed that some Hb variants, HbS and HbD-Iran, can alter the HbA1c level.
CONCLUSIONS: Since the HbA1c test is now recommended for diagnosing diabetes, and minimal variation of the concentration affects the clinical therapy, it is very important that the results are reliable and interference-free. Capillarys 2-FP analyzer is suitable for this purpose and sometimes it showed some advantages with respect to the HPLC analyzers tested, especially when Hb variants are present.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  diabetes; glycated hemoglobin; hemoglobinopathies

Mesh:

Substances:

Year:  2014        PMID: 24687307      PMCID: PMC6807185          DOI: 10.1002/jcla.21728

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  14 in total

1.  Multicenter evaluation of hemoglobin A1c assay on capillary electrophoresis.

Authors:  Mariela Marinova; Sara Altinier; Anna Caldini; Gabriella Passerini; Giorgio Pizzagalli; Marco Brogi; Martina Zaninotto; Ferruccio Ceriotti; Mario Plebani
Journal:  Clin Chim Acta       Date:  2013-06-20       Impact factor: 3.786

2.  HbA1c: performance of the Sebia Capillarys 2 Flex Piercing.

Authors:  Cas Weykamp; Helene Waenink-Wieggers; Erwin Kemna; Carla Siebelder
Journal:  Clin Chem Lab Med       Date:  2013-06       Impact factor: 3.694

3.  First evaluation of Capillarys 2 Flex Piercing® (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis.

Authors:  Stéphane Jaisson; Nathalie Leroy; Julie Meurice; Emmanuelle Guillard; Philippe Gillery
Journal:  Clin Chem Lab Med       Date:  2012-10-01       Impact factor: 3.694

4.  Co-inheritance of HbD (Iran)/Beta Thalassemia IVS1-5 (G > C) Trait in a Punjabi Lady with Diabetes.

Authors:  Vijay S Bhat; Amit Kumar Mandal; Bobby Mathew
Journal:  Indian J Clin Biochem       Date:  2012-03-24

Review 5.  Status of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care.

Authors:  Randie R Little; Curt L Rohlfing; David B Sacks
Journal:  Clin Chem       Date:  2010-12-09       Impact factor: 8.327

6.  International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes.

Authors: 
Journal:  Diabetes Care       Date:  2009-06-05       Impact factor: 17.152

7.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

8.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group.

Authors: 
Journal:  Lancet       Date:  1998-09-12       Impact factor: 79.321

9.  Estimation of biological variation and reference change value of glycated hemoglobin (HbA(1c)) when two analytical methods are used.

Authors:  Fatma Ucar; Gonul Erden; Zeynep Ginis; Gulfer Ozturk; Sevilay Sezer; Mukaddes Gurler; Ahmet Guneyk
Journal:  Clin Biochem       Date:  2013-06-01       Impact factor: 3.281

10.  Interference of the most frequent haemoglobin variants on quantification of HbA1c: comparison between the LC-MS (IFCC reference method) and three routinely used methods.

Authors:  S Jaisson; N Leroy; C Desroches; M Tonye-Libyh; E Guillard; P Gillery
Journal:  Diabetes Metab       Date:  2013-04-29       Impact factor: 6.041

View more
  7 in total

1.  Assessing agreement between the three common clinical measurement methods of HbA1c.

Authors:  Mohammad Taha Jalali; Samaneh Salehipour Bavarsad; Saeed Hesam; Mohammad Reza Afsharmanesh; Narges Mohammadtaghvaei
Journal:  J Diabetes Metab Disord       Date:  2020-02-11

2.  Hb I: A α-globin chain variant causing unexpected HbA1c results.

Authors:  Anping Xu; Jian Sun; Jie Li; Weidong Chen; Ruoyang Zheng; Zhonghou Han; Ling Ji
Journal:  J Clin Lab Anal       Date:  2018-09-17       Impact factor: 2.352

3.  Significantly High HbA1c in Diabetic Patient with Hb J: Case Report.

Authors:  Wan Nor Fazila Hafizan Wan Nik; Noorazliyana Shafii; Noor Azlin Azraini Che Soh; Rosnah Bahar
Journal:  Oman Med J       Date:  2022-07-31

Review 4.  Significance of HbA1c Test in Diagnosis and Prognosis of Diabetic Patients.

Authors:  Shariq I Sherwani; Haseeb A Khan; Aishah Ekhzaimy; Afshan Masood; Meena K Sakharkar
Journal:  Biomark Insights       Date:  2016-07-03

5.  Misleading HbA1c Measurement in Diabetic Patients with Hemoglobin Variants.

Authors:  Manthana Mitchai; Nattakarn Suwansaksri; Suphakdee Seanseeha; Jindamanee Saenboonsiri; Putthichai Kraitree; Jirasak Piyapromdee; Atit Silsirivanit
Journal:  Med Sci (Basel)       Date:  2021-06-07

6.  False measurement of glycated hemoglobin in patients without hemoglobin A.

Authors:  Minghuan Suo; Dongmei Wen; Weijia Wang; Decai Zhang; Shengnan Xu; Xia Wang; Ting Hu
Journal:  Biosci Rep       Date:  2019-01-30       Impact factor: 3.840

7.  HbA mutation causing false-normal HbA1c results determined by HPLC in a patient with type 2 diabetes mellitus: A case report.

Authors:  Juan Wang; Yi Wang; Wenshan Lv; Lili Yang; Meng Huang; Qing Wang
Journal:  Exp Ther Med       Date:  2021-06-07       Impact factor: 2.447

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.