Literature DB >> 24661056

Real-time image-processing algorithm for markerless tumour tracking using X-ray fluoroscopic imaging.

S Mori1.   

Abstract

OBJECTIVE: To ensure accuracy in respiratory-gating treatment, X-ray fluoroscopic imaging is used to detect tumour position in real time. Detection accuracy is strongly dependent on image quality, particularly positional differences between the patient and treatment couch. We developed a new algorithm to improve the quality of images obtained in X-ray fluoroscopic imaging and report the preliminary results.
METHODS: Two oblique X-ray fluoroscopic images were acquired using a dynamic flat panel detector (DFPD) for two patients with lung cancer. The weighting factor was applied to the DFPD image in respective columns, because most anatomical structures, as well as the treatment couch and port cover edge, were aligned in the superior-inferior direction when the patient lay on the treatment couch. The weighting factors for the respective columns were varied until the standard deviation of the pixel values within the image region was minimized. Once the weighting factors were calculated, the quality of the DFPD image was improved by applying the factors to multiframe images.
RESULTS: Applying the image-processing algorithm produced substantial improvement in the quality of images, and the image contrast was increased. The treatment couch and irradiation port edge, which were not related to a patient's position, were removed. The average image-processing time was 1.1 ms, showing that this fast image processing can be applied to real-time tumour-tracking systems.
CONCLUSION: These findings indicate that this image-processing algorithm improves the image quality in patients with lung cancer and successfully removes objects not related to the patient. ADVANCES IN KNOWLEDGE: Our image-processing algorithm might be useful in improving gated-treatment accuracy.

Entities:  

Mesh:

Year:  2014        PMID: 24661056      PMCID: PMC4075538          DOI: 10.1259/bjr.20140001

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  9 in total

1.  Clinical accuracy of ExacTrac intracranial frameless stereotactic system.

Authors:  T Ackerly; C M Lancaster; M Geso; K J Roxby
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

Review 2.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

3.  Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance.

Authors:  Stine S Korreman; Trine Juhler-Nøttrup; Arthur L Boyer
Journal:  Radiother Oncol       Date:  2007-11-26       Impact factor: 6.280

Review 4.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

5.  Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers.

Authors:  Ross I Berbeco; Hassan Mostafavi; Gregory C Sharp; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-09-13       Impact factor: 3.609

6.  CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle.

Authors:  F Laurent; V Latrabe; B Vergier; M Montaudon; J M Vernejoux; J Dubrez
Journal:  Clin Radiol       Date:  2000-04       Impact factor: 2.350

7.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

Authors:  Ross I Berbeco; Steve B Jiang; Gregory C Sharp; George T Chen; Hassan Mostafavi; Hiroki Shirato
Journal:  Phys Med Biol       Date:  2004-01-21       Impact factor: 3.609

8.  Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers.

Authors:  Ying Cui; Jennifer G Dy; Gregory C Sharp; Brian Alexander; Steve B Jiang
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

9.  Patient handling system for carbon ion beam scanning therapy.

Authors:  Shinichiro Mori; Toshiyuki Shirai; Yuka Takei; Takuji Furukawa; Taku Inaniwa; Yuka Matsuzaki; Motoki Kumagai; Takeshi Murakami; Koji Noda
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

  9 in total
  2 in total

1.  Novel real-time tumor-contouring method using deep learning to prevent mistracking in X-ray fluoroscopy.

Authors:  Toshiyuki Terunuma; Aoi Tokui; Takeji Sakae
Journal:  Radiol Phys Technol       Date:  2017-12-28

2.  The Emerging Role of Carbon-Ion Radiotherapy.

Authors:  Daniel K Ebner; Tadashi Kamada
Journal:  Front Oncol       Date:  2016-06-07       Impact factor: 6.244

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.