Literature DB >> 24658258

Design and experimental evaluation of a 256-channel dual-frequency ultrasound phased-array system for transcranial blood-brain barrier opening and brain drug delivery.

Hao-Li Liu, Chen-Kai Jan, Po-Chun Chu, Jhong-Cing Hong, Pei-Yun Lee, Jyh-Duen Hsu, Chung-Chih Lin, Chiung-Ying Huang, Pin-Yuan Chen, Kuo-Chen Wei.   

Abstract

Focused ultrasound (FUS) in the presence of microbubbles can bring about transcranial and local opening of the blood-brain barrier (BBB) for potential noninvasive delivery of drugs to the brain. A phased-array ultrasound system is essential for FUS-BBB opening to enable electronic steering and correction of the focal beam which is distorted by cranial bone. Here, we demonstrate our prototype design of a 256-channel ultrasound phased-array system for large-region transcranial BBB opening in the brains of large animals. One of the unique features of this system is the capability of generating concurrent dual-frequency ultrasound signals from the driving system for potential enhancement of BBB opening. A wide range of signal frequencies can be generated (frequency = 0.2-1.2 MHz) with controllable driving burst patterns. Precise output power can be controlled for individual channels via 8-bit duty-cycle control of transistor-transistor logic signals and the 8-bit microcontroller-controlled buck converter power supply output voltage. The prototype system was found to be in compliance with the electromagnetic compatibility standard. Moreover, large animal experiments confirmed the phase switching effectiveness of this system, and induction of either a precise spot or large region of BBB opening through fast focal-beam switching. We also demonstrated the capability of dual-frequency exposure to potentially enhance the BBB-opening effect. This study contributes to the design of ultrasound phased arrays for future clinical applications, and provides a new direction toward optimizing FUS brain drug delivery.

Entities:  

Mesh:

Year:  2014        PMID: 24658258     DOI: 10.1109/TBME.2014.2305723

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  15 in total

Review 1.  Promising approaches to circumvent the blood-brain barrier: progress, pitfalls and clinical prospects in brain cancer.

Authors:  Iason T Papademetriou; Tyrone Porter
Journal:  Ther Deliv       Date:  2015-08-25

2.  Design of patient-specific focused ultrasound arrays for non-invasive brain therapy with increased trans-skull transmission and steering range.

Authors:  Alec Hughes; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2017-08-03       Impact factor: 3.609

Review 3.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

4.  A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

Authors:  Lulu Deng; Meaghan A O'Reilly; Ryan M Jones; Ran An; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

Review 5.  Ultrasound treatment of neurological diseases--current and emerging applications.

Authors:  Gerhard Leinenga; Christian Langton; Rebecca Nisbet; Jürgen Götz
Journal:  Nat Rev Neurol       Date:  2016-02-19       Impact factor: 42.937

Review 6.  Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound.

Authors:  Scott Schoen; M Sait Kilinc; Hohyun Lee; Yutong Guo; F Levent Degertekin; Graeme F Woodworth; Costas Arvanitis
Journal:  Adv Drug Deliv Rev       Date:  2021-11-18       Impact factor: 15.470

7.  Transcranial Theranostic Ultrasound for Pre-Planning and Blood-Brain Barrier Opening: A Feasibility Study Using an Imaging Phased Array In Vitro and In Vivo.

Authors:  Alec Batts; Robin Ji; Alina Kline-Schoder; Rebecca Noel; Elisa Konofagou
Journal:  IEEE Trans Biomed Eng       Date:  2022-03-18       Impact factor: 4.538

8.  An Affordable and Easy-to-Use Focused Ultrasound Device for Noninvasive and High Precision Drug Delivery to the Mouse Brain.

Authors:  Zhongtao Hu; Si Chen; Yaoheng Yang; Yan Gong; Hong Chen
Journal:  IEEE Trans Biomed Eng       Date:  2022-08-19       Impact factor: 4.756

9.  Focused Ultrasound Platform for Investigating Therapeutic Neuromodulation Across the Human Hippocampus.

Authors:  Spencer T Brinker; Frank Preiswerk; Phillip J White; Timothy Y Mariano; Nathan J McDannold; Ellen J Bubrick
Journal:  Ultrasound Med Biol       Date:  2020-02-20       Impact factor: 2.998

10.  Trans-cranial opening of the blood-brain barrier in targeted regions using a stereotaxic brain atlas and focused ultrasound energy.

Authors:  Chenchen Bing; Michelle Ladouceur-Wodzak; Clinton R Wanner; John M Shelton; James A Richardson; Rajiv Chopra
Journal:  J Ther Ultrasound       Date:  2014-08-04
View more