Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices.

Angelo Nascimbene1, Ruben Hernandez2, Joggy K George1, Anita Parker2, Angela L Bergeron3, Subhashree Pradhan3, K Vinod Vijayan3, Andrew Civitello1, Leo Simpson1, Maria Nawrot4, Vei-Vei Lee5, Hari R Mallidi2, Reynolds M Delgado1, Jing Fei Dong6, O H Frazier7.   

Abstract

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients.
METHODS: We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry.
RESULTS: During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p < 0.001), even though the 2 patient groups did not markedly differ in other clinical and hematologic parameters.
CONCLUSIONS: Our results suggest that an elevation of PS+ microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events.
Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cell-derived microparticles; phosphatidylserine; ventricular assist device

Mesh:

Year:  2014        PMID: 24656391      PMCID: PMC3992167          DOI: 10.1016/j.healun.2014.01.004

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  29 in total

1.  Platelet microparticle membranes have 50- to 100-fold higher specific procoagulant activity than activated platelets.

Authors:  Elena I Sinauridze; Dmitry A Kireev; Nadezhda Y Popenko; Aleksei V Pichugin; Mikhail A Panteleev; Olga V Krymskaya; Fazoil I Ataullakhanov
Journal:  Thromb Haemost       Date:  2007-03       Impact factor: 5.249

2.  Asymmetric pattern of cerebrovascular lesions in patients after left ventricular assist device implantation.

Authors:  Tomoko S Kato; Takeyoshi Ota; P Christian Schulze; Maryjane Farr; Ulrich Jorde; Hiroo Takayama; Yoshifumi Naka; Toru Yamashita; Donna M Mancini
Journal:  Stroke       Date:  2011-12-29       Impact factor: 7.914

3.  Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device.

Authors:  George V Letsou; Nyma Shah; Igor D Gregoric; Timothy J Myers; Reynolds Delgado; O H Frazier
Journal:  J Heart Lung Transplant       Date:  2005-01       Impact factor: 10.247

4.  Severely impaired von Willebrand factor-dependent platelet aggregation in patients with a continuous-flow left ventricular assist device (HeartMate II).

Authors:  Jolanta Klovaite; Finn Gustafsson; Svend A Mortensen; Kåre Sander; Lars B Nielsen
Journal:  J Am Coll Cardiol       Date:  2009-06-09       Impact factor: 24.094

5.  Advanced heart failure treated with continuous-flow left ventricular assist device.

Authors:  Mark S Slaughter; Joseph G Rogers; Carmelo A Milano; Stuart D Russell; John V Conte; David Feldman; Benjamin Sun; Antone J Tatooles; Reynolds M Delgado; James W Long; Thomas C Wozniak; Waqas Ghumman; David J Farrar; O Howard Frazier
Journal:  N Engl J Med       Date:  2009-11-17       Impact factor: 91.245

6.  Cerebrovascular accidents in patients with a ventricular assist device.

Authors:  Hiroyuki Tsukui; Adib Abla; Jeffrey J Teuteberg; Dennis M McNamara; Michael A Mathier; Linda M Cadaret; Robert L Kormos
Journal:  J Thorac Cardiovasc Surg       Date:  2007-06-04       Impact factor: 5.209

7.  Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices.

Authors:  Sheri Crow; Ranjit John; Andrew Boyle; Sara Shumway; Kenneth Liao; Monica Colvin-Adams; Carol Toninato; Emil Missov; Marc Pritzker; Cindy Martin; Daniel Garry; William Thomas; Lyle Joyce
Journal:  J Thorac Cardiovasc Surg       Date:  2008-10-10       Impact factor: 5.209

8.  Low thromboembolic risk for patients with the Heartmate II left ventricular assist device.

Authors:  Ranjit John; Forum Kamdar; Kenneth Liao; Monica Colvin-Adams; Leslie Miller; Lyle Joyce; Andrew Boyle
Journal:  J Thorac Cardiovasc Surg       Date:  2008-09-14       Impact factor: 5.209

9.  Shed membrane microparticles with procoagulant potential in human atherosclerotic plaques: a role for apoptosis in plaque thrombogenicity.

Authors:  Z Mallat; B Hugel; J Ohan; G Lesèche; J M Freyssinet; A Tedgui
Journal:  Circulation       Date:  1999-01-26       Impact factor: 29.690

10.  Platelet-derived exosomes induce endothelial cell apoptosis through peroxynitrite generation: experimental evidence for a novel mechanism of septic vascular dysfunction.

Authors:  Marcela Helena Gambim; Alipio de Oliveira do Carmo; Luciana Marti; Sidney Veríssimo-Filho; Lucia Rossetti Lopes; Mariano Janiszewski
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

View more
  11 in total

Review 1.  Microparticles and cardiovascular diseases.

Authors:  Christos Voukalis; Eduard Shantsila; Gregory Y H Lip
Journal:  Ann Med       Date:  2019-06-17       Impact factor: 4.709

2.  Production of erythrocyte microparticles in a sub-hemolytic environment.

Authors:  James P Buerck; Dustin K Burke; David W Schmidtke; Trevor A Snyder; Dimitrios V Papavassiliou; Edgar A O'Rear
Journal:  J Artif Organs       Date:  2021-01-09       Impact factor: 1.731

Review 3.  Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review.

Authors:  Sung M Cho; Nader Moazami; Jennifer A Frontera
Journal:  Neurocrit Care       Date:  2017-08       Impact factor: 3.210

Review 4.  Physiological impact of continuous flow on end-organ function: clinical implications in the current era of left ventricular assist devices.

Authors:  Arvind Bhimaraj; Cesar Uribe; Erick E Suarez
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar

5.  Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit.

Authors:  Patrick Borchers; Patrick Winnersbach; Sandra Kraemer; Christian Beckers; Eva Miriam Buhl; Steffen Leonhardt; Rolf Rossaint; Marian Walter; Thomas Breuer; Christian Bleilevens
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

6.  Gastrointestinal Bleeding as a Complication in Continuous Flow Ventricular Assist Devices: A Systematic Review With Meta-Analysis.

Authors:  Edinen Asuka; Stella Pak; Armond-Kristopher Thiess; Anthony Torres
Journal:  J Clin Med Res       Date:  2020-08-15

7.  Platelet-derived microparticles generated by neonatal extracorporeal membrane oxygenation systems.

Authors:  Andrew D Meyer; Jonathan A L Gelfond; Andrew A Wiles; Robert J Freishtat; Khoydar Rais-Bahrami
Journal:  ASAIO J       Date:  2015 Jan-Feb       Impact factor: 2.872

Review 8.  Left ventricular assist devices: a kidney's perspective.

Authors:  T R Tromp; N de Jonge; J A Joles
Journal:  Heart Fail Rev       Date:  2015-07       Impact factor: 4.214

Review 9.  The Inflammatory Response to Ventricular Assist Devices.

Authors:  Gemma Radley; Ina Laura Pieper; Sabrina Ali; Farah Bhatti; Catherine A Thornton
Journal:  Front Immunol       Date:  2018-11-15       Impact factor: 7.561

10.  Platelet Dysfunction During Mechanical Circulatory Support: Elevated Shear Stress Promotes Downregulation of αIIbβ3 and GPIb via Microparticle Shedding Decreasing Platelet Aggregability.

Authors:  Yana Roka-Moiia; Samuel Miller-Gutierrez; Daniel E Palomares; Joseph E Italiano; Jawaad Sheriff; Danny Bluestein; Marvin J Slepian
Journal:  Arterioscler Thromb Vasc Biol       Date:  2021-02-11       Impact factor: 8.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.