Abstract

New materials and designs for neural implants are typically tested separately, with a demonstration of performance but without reference to other implant characteristics. This precludes a rational selection of a particular implant as optimal for a particular application and the development of new materials based on the most critical performance parameters. This article develops a protocol for in vitro and in vivo testing of neural recording electrodes. Recommended parameters for electrochemical and electrophysiological testing are documented with the key steps and potential issues discussed. This method eliminates or reduces the impact of many systematic errors present in simpler in vivo testing paradigms, especially variations in electrode/neuron distance and between animal models. The result is a strong correlation between the critical in vitro and in vivo responses, such as impedance and signal-to-noise ratio. This protocol can easily be adapted to test other electrode materials and designs. The in vitro techniques can be expanded to any other nondestructive method to determine further important performance indicators. The principles used for the surgical approach in the auditory pathway can also be modified to other neural regions or tissue.

Mesh:

Substances:

Year:  2014        PMID: 24637902      PMCID: PMC4123517          DOI: 10.3791/51084

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  11 in total

1.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes.

Authors:  X Liu; D B McCreery; R R Carter; L A Bullara; T G Yuen; W F Agnew
Journal:  IEEE Trans Rehabil Eng       Date:  1999-09

2.  Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.

Authors:  J C Williams; R L Rennaker; D R Kipke
Journal:  Brain Res Brain Res Protoc       Date:  1999-12

3.  Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex.

Authors:  P J Rousche; R A Normann
Journal:  J Neurosci Methods       Date:  1998-07-01       Impact factor: 2.390

4.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.

Authors:  Roy Biran; David C Martin; Patrick A Tresco
Journal:  Exp Neurol       Date:  2005-09       Impact factor: 5.330

5.  Inferior colliculus responses to multichannel microstimulation of the ventral cochlear nucleus: implications for auditory brain stem implants.

Authors:  Mohit N Shivdasani; Stefan J Mauger; Graeme D Rathbone; Antonio G Paolini
Journal:  J Neurophysiol       Date:  2007-10-10       Impact factor: 2.714

Review 6.  Deep brain stimulation.

Authors:  Joel S Perlmutter; Jonathan W Mink
Journal:  Annu Rev Neurosci       Date:  2006       Impact factor: 12.449

7.  Conducting polymer coated neural recording electrodes.

Authors:  Alexander R Harris; Simeon J Morgan; Jun Chen; Robert M I Kapsa; Gordon G Wallace; Antonio G Paolini
Journal:  J Neural Eng       Date:  2012-12-12       Impact factor: 5.379

8.  Addressing neurological disorders with neuromodulation.

Authors:  Chima O Oluigbo; Ali R Rezai
Journal:  IEEE Trans Biomed Eng       Date:  2010-12-30       Impact factor: 4.538

9.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film.

Authors:  Kip A Ludwig; Jeffrey D Uram; Junyan Yang; David C Martin; Daryl R Kipke
Journal:  J Neural Eng       Date:  2006-03-01       Impact factor: 5.379

10.  Bilateral deep brain stimulation vs best medical therapy for patients with advanced Parkinson disease: a randomized controlled trial.

Authors:  Frances M Weaver; Kenneth Follett; Matthew Stern; Kwan Hur; Crystal Harris; William J Marks; Johannes Rothlind; Oren Sagher; Domenic Reda; Claudia S Moy; Rajesh Pahwa; Kim Burchiel; Penelope Hogarth; Eugene C Lai; John E Duda; Kathryn Holloway; Ali Samii; Stacy Horn; Jeff Bronstein; Gatana Stoner; Jill Heemskerk; Grant D Huang
Journal:  JAMA       Date:  2009-01-07       Impact factor: 56.272

View more
  1 in total

Review 1.  Functional and Histological Effects of Chronic Neural Electrode Implantation.

Authors:  Ronald Sahyouni; David T Chang; Omid Moshtaghi; Amin Mahmoodi; Hamid R Djalilian; Harrison W Lin
Journal:  Laryngoscope Investig Otolaryngol       Date:  2017-02-06
  1 in total