Literature DB >> 16510943

Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film.

Kip A Ludwig1, Jeffrey D Uram, Junyan Yang, David C Martin, Daryl R Kipke.   

Abstract

Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16510943     DOI: 10.1088/1741-2560/3/1/007

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  151 in total

1.  Clearly, Graphene is the New Gold.

Authors:  William Stacey
Journal:  Epilepsy Curr       Date:  2015 Nov-Dec       Impact factor: 7.500

2.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

3.  Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.

Authors:  Arati Sridharan; Jessica K Nguyen; Jeffrey R Capadona; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2015-04-02       Impact factor: 5.379

4.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

5.  Aptamer-functionalized neural recording electrodes for the direct measurement of cocaine in vivo.

Authors:  I Mitch Taylor; Zhanhong Du; Emma T Bigelow; James R Eles; Anthony R Horner; Kasey A Catt; Stephen G Weber; Brian G Jamieson; X Tracy Cui
Journal:  J Mater Chem B       Date:  2017-03-06       Impact factor: 6.331

6.  The Glutamatergic Postrhinal Cortex-Ventrolateral Orbitofrontal Cortex Pathway Regulates Spatial Memory Retrieval.

Authors:  Xinyang Qi; Zhanhong Jeff Du; Lin Zhu; Xuemei Liu; Hua Xu; Zheng Zhou; Cheng Zhong; Shijiang Li; Liping Wang; Zhijun Zhang
Journal:  Neurosci Bull       Date:  2019-01-02       Impact factor: 5.203

7.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

Review 8.  Improving data quality in neuronal population recordings.

Authors:  Kenneth D Harris; Rodrigo Quian Quiroga; Jeremy Freeman; Spencer L Smith
Journal:  Nat Neurosci       Date:  2016-08-26       Impact factor: 24.884

9.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

10.  Insertion of a three dimensional silicon microelectrode assembly through a thick meningeal membrane.

Authors:  Taneev Escamilla-Mackert; Nicholas B Langhals; Takashi D Y Kozai; Daryl R Kipke
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.