Literature DB >> 24629419

A randomized controlled trial assessing the effect of prescribed patient position changes during colonoscope withdrawal on adenoma detection.

George Ou1, Edward Kim1, Pardis Lakzadeh1, Jessica Tong1, Robert Enns1, Alnoor Ramji1, Scott Whittaker1, Hin Hin Ko1, Brian Bressler1, Lawrence Halparin1, Eric Lam1, Jack Amar1, Jennifer Telford1.   

Abstract

BACKGROUND: High-quality colonoscope withdrawal technique is associated with a higher adenoma detection rate. Position change is routinely used in barium enema and CT colonography to facilitate adequate distension of the colon and promote movement of fluid from the segment of the colon being assessed.
OBJECTIVE: To determine whether prescribed position changes during colonoscope withdrawal affect the adenoma detection rate compared with the usual care per endoscopist.
DESIGN: Prospective, randomized, controlled trial.
SETTING: Tertiary-care, university-affiliated hospital. PATIENTS: Patients referred for outpatient colonoscopy between July 2011 and July 2012 were evaluated for eligibility. Inclusion criteria were outpatient status and age ≥40 years. Exclusion criteria were (1) complete colonoscopy within 1 year before the procedure, (2) inability to provide informed consent, (3) incomplete colonoscopy to the cecum, (4) previous bowel resection, (5) inflammatory bowel disease, (6) colonic polyposis syndrome, (7) inadequate bowel preparation, and (8) musculoskeletal disorder or other mobility issues limiting effective patient position changes during colonoscopy.
INTERVENTIONS: Prescribed position changes during colonoscope withdrawal. MAIN OUTCOME MEASUREMENTS: Polyp detection rate (PDR) and adenoma detection rate (ADR).
RESULTS: A total of 776 patients were enrolled, with 388 in the dynamic group. There was no difference in PDR (odds ratio [OR] 0.99; P = .93) or ADR (OR 1.17; P = .28). Colonoscope withdrawal time was longer in the dynamic group (median time 466.5 vs 422.5 seconds; P < .0001). LIMITATIONS: Single-center study. Indication for procedure not controlled. Lack of standardized bowel preparation and blinding.
CONCLUSION: Prescribed position changes during colonoscope withdrawal do not affect polyp/adenoma detection compared with the usual practice when the baseline ADR is above the recommended standard. ( CLINICAL TRIAL REGISTRATION NUMBER: NCT01395173.).
Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24629419     DOI: 10.1016/j.gie.2014.01.032

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  14 in total

1.  Does the "polyp paradox" really exist?

Authors:  Helmut Neumann; Rungsun Rerknimitr
Journal:  Dig Dis Sci       Date:  2014-08-05       Impact factor: 3.199

2.  Response to Zhao et al.

Authors:  Seung-Woo Lee; Jae Hyuck Chang; Jeong-Seon Ji
Journal:  Am J Gastroenterol       Date:  2016-09       Impact factor: 10.864

3.  Is Dynamic Position Changes an Effective Way to Improve the Adenoma Detection Rate?

Authors:  Sheng-Bing Zhao; Hui Wan; Zhao-Shen Li; Yu Bai
Journal:  Am J Gastroenterol       Date:  2016-09       Impact factor: 10.864

Review 4.  Strategies to Increase Adenoma Detection Rates.

Authors:  Eelco C Brand; Michael B Wallace
Journal:  Curr Treat Options Gastroenterol       Date:  2017-03

Review 5.  Seeing better--Evidence based recommendations on optimizing colonoscopy adenoma detection rate.

Authors:  Javier Aranda-Hernández; Jason Hwang; Gabor Kandel
Journal:  World J Gastroenterol       Date:  2016-02-07       Impact factor: 5.742

Review 6.  Quality indicators for colonoscopy: Current insights and caveats.

Authors:  Hendrikus Jm Pullens; Peter D Siersema
Journal:  World J Gastrointest Endosc       Date:  2014-12-16

7.  The Impact of the Colonoscopy Starting Position and Its Potential Outcomes.

Authors:  Pallavi Shah; Nehal Patel; Alhareth Alsayed; Steven Miller; Nitish Singh Nandu
Journal:  Cureus       Date:  2022-05-14

8.  Effect of Dynamic Position Changes on Adenoma Detection During Colonoscope Withdrawal: A Randomized Controlled Multicenter Trial.

Authors:  Seung-Woo Lee; Jae Hyuck Chang; Jeong-Seon Ji; Il Ho Maeong; Dae Young Cheung; Joon Sung Kim; Young-Seok Cho; Wook-Jin Chung; Bo-In Lee; Sang-Woo Kim; Byung-Wook Kim; Hwang Choi; Myung-Gyu Choi
Journal:  Am J Gastroenterol       Date:  2015-11-03       Impact factor: 10.864

9.  Optimizing Colonoscopy Quality: From Bowel Preparation to Surveillance.

Authors:  Carla G Abou Fadel; Rani H Shayto; Ala I Sharara
Journal:  Curr Treat Options Gastroenterol       Date:  2016-03

Review 10.  Expert opinions and scientific evidence for colonoscopy key performance indicators.

Authors:  Colin J Rees; Roisin Bevan; Katharina Zimmermann-Fraedrich; Matthew D Rutter; Douglas Rex; Evelien Dekker; Thierry Ponchon; Michael Bretthauer; Jaroslaw Regula; Brian Saunders; Cesare Hassan; Michael J Bourke; Thomas Rösch
Journal:  Gut       Date:  2016-10-08       Impact factor: 23.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.