Literature DB >> 24614646

Challenges in longitudinal measurements with HR-pQCT: evaluation of a 3D registration method to improve bone microarchitecture and strength measurement reproducibility.

Rafaa Ellouz1, Roland Chapurlat2, Bert van Rietbergen3, Patrik Christen4, Jean-Baptiste Pialat5, Stephanie Boutroy6.   

Abstract

Definition of identical regions between repeated computed tomography (CT) scans is a key factor to monitor changes in bone microarchitecture. In longitudinal studies, accurate determination of the volume of interest (VOI), using three dimensional (3D) registration may improve precision. Therefore, the aim of our study was to investigate the short-term reproducibility of bone geometry, density, microstructure and biomechanical parameters assessed by HR-pQCT and micro-finite element (μFE) derived analyses, using the cross-sectional area (CSA) registration method in comparison with the use of 3D registration, to find overlapping regions between scans. Fifteen healthy individuals (aged 21-47 years) underwent 3 separate scans at the distal radius and tibia, within a one-month interval. Reproducibility was assessed after double contouring the cortical compartment and after applying three different methods to determine the common region between repeated scans: (i) the VOI was determined with no registration, i.e., on 110 slices, (ii) the VOI was determined after CSA-based registration, and (iii) the VOI was determined after 3D registration. Both pre- and post-registration short-term reproducibility for each subject was determined. With no registration, CVrms of geometry parameters ranged from 0.5 to 3.7%, showing a slight variation in the CSA between scans. When the CSA registration method was employed, the variability of geometry (CVrms<1.8%) and density parameters (CVrms<1.8%), was better than that obtained without registration. By removing the effect of repositioning, the 3D registration further improved the reproducibility of cortical bone measurements compared to other methods. Indeed, significant improvements were found for cortical geometry and microstructure measurements (CVrms ranged from 0.4% to 10.7% at both sites; p<0.05), whereas the impact on trabecular bone measurements was restricted to its geometry parameter. The repositioning error was significantly reduced, most markedly at the radius compared to the tibia. For μFE measures, the impact of 3D registration on whole bone stiffness was negligible, indicating adequate assessment of longitudinal changes in estimated biomechanical properties, even without registration. In conclusion, we have shown that the 3D registration improved the identification of the common region retained for longitudinal analysis, contributing to improve the reproducibility of cortical bone parameter measurements. We also quantified the minimally detectable bone changes to help designing future studies with HR-pQCT.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D registration; Bone microarchitecture; Bone strength; HR-pQCT; Short-term reproducibility

Mesh:

Year:  2014        PMID: 24614646     DOI: 10.1016/j.bone.2014.03.001

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  20 in total

1.  Using 3D image registration to maximize the reproducibility of longitudinal bone strength assessment by HR-pQCT and finite element analysis.

Authors:  R M Plett; T D Kemp; L A Burt; E O Billington; D A Hanley; S K Boyd
Journal:  Osteoporos Int       Date:  2021-02-24       Impact factor: 4.507

Review 2.  In vivo Visualisation and Quantification of Bone Resorption and Bone Formation from Time-Lapse Imaging.

Authors:  Patrik Christen; Ralph Müller
Journal:  Curr Osteoporos Rep       Date:  2017-08       Impact factor: 5.096

3.  Technical note: early post-mortem changes of human bone in taphonomy with μCT.

Authors:  Erwan Le Garff; Vadim Mesli; Yann Delannoy; Thomas Colard; Xavier Demondion; Anne Becart; Valéry Hedouin
Journal:  Int J Legal Med       Date:  2016-12-29       Impact factor: 2.686

4.  Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone.

Authors:  C de Charry; S Boutroy; R Ellouz; F Duboeuf; R Chapurlat; H Follet; J B Pialat
Journal:  Osteoporos Int       Date:  2016-04-28       Impact factor: 4.507

5.  Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training.

Authors:  S Bonaretti; N Vilayphiou; C M Chan; A Yu; K Nishiyama; D Liu; S Boutroy; A Ghasem-Zadeh; S K Boyd; R Chapurlat; H McKay; E Shane; M L Bouxsein; D M Black; S Majumdar; E S Orwoll; T F Lang; S Khosla; A J Burghardt
Journal:  Osteoporos Int       Date:  2016-07-30       Impact factor: 4.507

6.  Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography.

Authors:  D E Whittier; S K Boyd; A J Burghardt; J Paccou; A Ghasem-Zadeh; R Chapurlat; K Engelke; M L Bouxsein
Journal:  Osteoporos Int       Date:  2020-05-26       Impact factor: 4.507

7.  Effect of High-Dose Vitamin D Supplementation on Volumetric Bone Density and Bone Strength: A Randomized Clinical Trial.

Authors:  Lauren A Burt; Emma O Billington; Marianne S Rose; Duncan A Raymond; David A Hanley; Steven K Boyd
Journal:  JAMA       Date:  2019-08-27       Impact factor: 56.272

8.  Fermented dairy products consumption is associated with attenuated cortical bone loss independently of total calcium, protein, and energy intakes in healthy postmenopausal women.

Authors:  E Biver; C Durosier-Izart; F Merminod; T Chevalley; B van Rietbergen; S L Ferrari; R Rizzoli
Journal:  Osteoporos Int       Date:  2018-05-03       Impact factor: 4.507

Review 9.  In vivo evaluation of bone microstructure in humans: Clinically useful?

Authors:  Roland Chapurlat
Journal:  Bonekey Rep       Date:  2016-06-15

10.  Voxel size dependency, reproducibility and sensitivity of an in vivo bone loading estimation algorithm.

Authors:  Patrik Christen; Friederike A Schulte; Alexander Zwahlen; Bert van Rietbergen; Stephanie Boutroy; L Joseph Melton; Shreyasee Amin; Sundeep Khosla; Jörg Goldhahn; Ralph Müller
Journal:  J R Soc Interface       Date:  2016-01       Impact factor: 4.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.