Literature DB >> 24596178

Optimizing capillary electrophoresis for top-down proteomics of 30-80 kDa proteins.

Yihan Li1, Philip D Compton, John C Tran, Ioanna Ntai, Neil L Kelleher.   

Abstract

The direct analysis of intact proteins via MS offers compelling advantages in comparison to alternative methods due to the direct and unambiguous identification and characterization of protein sequences it provides. The inability to efficiently analyze proteins in the "middle mass range," defined here as proteins from 30 to 80 kDa, in a robust fashion has limited the adoption of these "top-down" methods. Largely, a result of poor liquid chromatographic performance, the limitations in this mass range may be addressed by alternative separations that replace chromatography. Herein, the short migration times of CZE-ESI-MS/MS have been extended to size-sorted whole proteins in complex mixtures from Pseudomonas aeruginosa PA01. An electrokinetically pumped nanospray interface, a coated capillary, and a stacking method for on-column sample concentration were developed to achieve high-loading capacity and separation resolution. We achieved full width at half maximum of 8-16 s for model proteins up to 29 kDa and identified 30 proteins in the mass range of 30-80 kDa from P. aeruginosa PA01 whole cell lysate. These results suggest that CZE-ESI-MS/MS is capable of identifying proteins in the middle mass range in top-down proteomics.
© 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  CZE-ESI-MS/MS; Pseudomonas aeruginosa PA01; Technology; Top-down proteomics

Mesh:

Substances:

Year:  2014        PMID: 24596178      PMCID: PMC4034378          DOI: 10.1002/pmic.201300381

Source DB:  PubMed          Journal:  Proteomics        ISSN: 1615-9853            Impact factor:   3.984


  22 in total

Review 1.  Polymer wall coatings for capillary electrophoresis.

Authors:  J Horvath; V Dolník
Journal:  Electrophoresis       Date:  2001       Impact factor: 3.535

2.  Capillary electrophoresis.

Authors:  Matthew Geiger; Amy L Hogerton; Michael T Bowser
Journal:  Anal Chem       Date:  2011-12-28       Impact factor: 6.986

3.  Using ProSight PTM and related tools for targeted protein identification and characterization with high mass accuracy tandem MS data.

Authors:  Richard D Leduc; Neil L Kelleher
Journal:  Curr Protoc Bioinformatics       Date:  2007-09

4.  Proteoform: a single term describing protein complexity.

Authors:  Lloyd M Smith; Neil L Kelleher
Journal:  Nat Methods       Date:  2013-03       Impact factor: 28.547

5.  Robust analysis of the yeast proteome under 50 kDa by molecular-mass-based fractionation and top-down mass spectrometry.

Authors:  John F Kellie; Adam D Catherman; Kenneth R Durbin; John C Tran; Jeremiah D Tipton; Jeremy L Norris; Charles E Witkowski; Paul M Thomas; Neil L Kelleher
Journal:  Anal Chem       Date:  2011-12-14       Impact factor: 6.986

6.  Intact mass detection, interpretation, and visualization to automate Top-Down proteomics on a large scale.

Authors:  Kenneth R Durbin; John C Tran; Leonid Zamdborg; Steve M M Sweet; Adam D Catherman; Ji Eun Lee; Mingxi Li; John F Kellie; Neil L Kelleher
Journal:  Proteomics       Date:  2010-10       Impact factor: 3.984

7.  Nano-LC FTICR tandem mass spectrometry for top-down proteomics: routine baseline unit mass resolution of whole cell lysate proteins up to 72 kDa.

Authors:  Jeremiah D Tipton; John C Tran; Adam D Catherman; Dorothy R Ahlf; Kenneth R Durbin; Ji Eun Lee; John F Kellie; Neil L Kelleher; Christopher L Hendrickson; Alan G Marshall
Journal:  Anal Chem       Date:  2012-02-22       Impact factor: 6.986

8.  CZE-ESI-MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate.

Authors:  Liangliang Sun; Guijie Zhu; Yihan Li; Roza Wojcik; Ping Yang; Norman J Dovichi
Journal:  Proteomics       Date:  2012-08-29       Impact factor: 3.984

9.  Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50 min separation.

Authors:  Guijie Zhu; Liangliang Sun; Xiaojing Yan; Norman J Dovichi
Journal:  Anal Chem       Date:  2013-02-13       Impact factor: 6.986

10.  Application of capillary electrophoresis/ electrospray ionization-mass spectrometry to subcellular proteomics of Escherichia coli ribosomal proteins.

Authors:  Mehdi Moini; Hsiaoling Huang
Journal:  Electrophoresis       Date:  2004-07       Impact factor: 3.595

View more
  33 in total

1.  A comprehensive pipeline for translational top-down proteomics from a single blood draw.

Authors:  Timothy K Toby; Luca Fornelli; Kristina Srzentić; Caroline J DeHart; Josh Levitsky; John Friedewald; Neil L Kelleher
Journal:  Nat Protoc       Date:  2019-01       Impact factor: 13.491

2.  Top-Down Proteomics of Large Proteins up to 223 kDa Enabled by Serial Size Exclusion Chromatography Strategy.

Authors:  Wenxuan Cai; Trisha Tucholski; Bifan Chen; Andrew J Alpert; Sean McIlwain; Takushi Kohmoto; Song Jin; Ying Ge
Journal:  Anal Chem       Date:  2017-05-02       Impact factor: 6.986

3.  Deep Top-Down Proteomics Using Capillary Zone Electrophoresis-Tandem Mass Spectrometry: Identification of 5700 Proteoforms from the Escherichia coli Proteome.

Authors:  Elijah N McCool; Rachele A Lubeckyj; Xiaojing Shen; Daoyang Chen; Qiang Kou; Xiaowen Liu; Liangliang Sun
Journal:  Anal Chem       Date:  2018-04-09       Impact factor: 6.986

Review 4.  Progress in Top-Down Proteomics and the Analysis of Proteoforms.

Authors:  Timothy K Toby; Luca Fornelli; Neil L Kelleher
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2016-06-12       Impact factor: 10.745

5.  Third-generation electrokinetically pumped sheath-flow nanospray interface with improved stability and sensitivity for automated capillary zone electrophoresis-mass spectrometry analysis of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Zhenbin Zhang; Si Mou; Norman J Dovichi
Journal:  J Proteome Res       Date:  2015-03-27       Impact factor: 4.466

6.  Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex.

Authors:  Sam B Choi; Marta Zamarbide; M Chiara Manzini; Peter Nemes
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-16       Impact factor: 3.109

Review 7.  Identification and Quantification of Proteoforms by Mass Spectrometry.

Authors:  Leah V Schaffer; Robert J Millikin; Rachel M Miller; Lissa C Anderson; Ryan T Fellers; Ying Ge; Neil L Kelleher; Richard D LeDuc; Xiaowen Liu; Samuel H Payne; Liangliang Sun; Paul M Thomas; Trisha Tucholski; Zhe Wang; Si Wu; Zhijie Wu; Dahang Yu; Michael R Shortreed; Lloyd M Smith
Journal:  Proteomics       Date:  2019-05       Impact factor: 3.984

8.  High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest.

Authors:  Nicole M Schiavone; Scott A Sarver; Liangliang Sun; Roza Wojcik; Norman J Dovichi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-04-09       Impact factor: 3.205

Review 9.  Capillary zone electrophoresis as a tool for bottom-up protein analysis.

Authors:  Roza Wojcik; Guijie Zhu; Zhenbin Zhang; Xiaojing Yan; Yimeng Zhao; Liangliang Sun; Matthew M Champion; Norman J Dovichi
Journal:  Bioanalysis       Date:  2015-12-10       Impact factor: 2.681

10.  Coupling Capillary Zone Electrophoresis to a Q Exactive HF Mass Spectrometer for Top-down Proteomics: 580 Proteoform Identifications from Yeast.

Authors:  Yimeng Zhao; Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  J Proteome Res       Date:  2016-08-25       Impact factor: 4.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.