Literature DB >> 24578275

Quiet T1-weighted imaging using PETRA: initial clinical evaluation in intracranial tumor patients.

Masahiro Ida1, Toshiki Wakayama, Matthew L Nielsen, Takayuki Abe, David M Grodzki.   

Abstract

PURPOSE: To compare the lesion contrast and signal to noise ratio (SNR) obtained with T1-weighted pointwise encoding time reduction with radial acquisition (PETRA) to those of Magnetization-Prepared RApid Gradient-Echo (MPRAGE) for contrast-enhanced imaging of primary and metastatic intracranial tumors, and to investigate whether PETRA is able to reduce acoustic noise for improved patient comfort.
MATERIALS AND METHODS: Fifteen patients with intracranial tumors underwent 3 Tesla MRI including inversion-prepared PETRA and MPRAGE. The two sequences had comparable scan times, spatial resolution and spatial coverage. "Tumor conspicuity" was rated qualitatively by two radiologists, while enhancing lesion-to-white matter contrast to noise ratio (CNR) and white-matter SNR were analyzed quantitatively using paired t-tests. The acoustic noise generated by each sequence was measured.
RESULTS: Qualitative rating of "tumor conspicuity" by two radiologists resulted in nearly identical average scores for the two sequences. Quantitative analyses revealed that (i) there was no significant difference between the mean CNR values of the two sequences (P = 0.57), (ii) the mean SNR of PETRA was significantly higher than that of MPRAGE (P < 0.01), and (iii) the mean sound level of PETRA was significantly lower than that of MPRAGE (P < 0.01).
CONCLUSION: Inversion-prepared PETRA was found to be viable as a quiet alternative to MPRAGE for contrast-enhanced T1-weighted studies of intracranial tumors.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  PETRA (pointwise encoding time reduction with radial acquisition); contrast-enhanced T1-weighted; intracranial brain tumor; point-wise, pointwise; quiet; ultra-short TE, ultrashort TE

Mesh:

Substances:

Year:  2014        PMID: 24578275     DOI: 10.1002/jmri.24575

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  13 in total

1.  Characterization of hardware-related spatial distortions for IR-PETRA pulse sequence using a brain specific phantom.

Authors:  Sima Ahmadian; Iraj Jabbari; Seyed Mehdi Bagherimofidi; Hamidreza Saligheh Rad
Journal:  MAGMA       Date:  2020-07-06       Impact factor: 2.310

2.  Quiet MR sequences in clinical routine: initial experience in abdominal imaging.

Authors:  Sebastian Fischer; David M Grodzki; Markus Domschke; Moritz Albrecht; Boris Bodelle; Katrin Eichler; Renate Hammerstingl; Thomas J Vogl; Stephan Zangos
Journal:  Radiol Med       Date:  2016-11-28       Impact factor: 3.469

3.  Qualitative and quantitative analysis of 3D T1 Silent imaging.

Authors:  Francesca Di Giuliano; Silvia Minosse; Eliseo Picchi; Valentina Ferrazzoli; Valerio Da Ros; Massimo Muto; Chiara Adriana Pistolese; Francesco Garaci; Roberto Floris
Journal:  Radiol Med       Date:  2021-06-15       Impact factor: 3.469

Review 4.  UTE imaging in the musculoskeletal system.

Authors:  Eric Y Chang; Jiang Du; Christine B Chung
Journal:  J Magn Reson Imaging       Date:  2014-07-16       Impact factor: 4.813

5.  Quiet PROPELLER MRI techniques match the quality of conventional PROPELLER brain imaging techniques.

Authors:  I Corcuera-Solano; A Doshi; P S Pawha; D Gui; A Gaddipati; L Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-12       Impact factor: 3.825

6.  Comparison of contrast-enhanced T1-weighted imaging using DANTE-SPACE, PETRA, and MPRAGE: a clinical evaluation of brain tumors at 3 Tesla.

Authors:  Zi-Qiao Lei; Chuan-Sheng Zheng; Qing Fu; Qi-Guang Cheng; Xiang-Chuang Kong; Ding-Xi Liu; Yi-Hao Guo; John Grinstead; Xiao-Yong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-01

7.  Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla.

Authors:  Qing Fu; Ding-Xi Liu; Xiao-Yong Zhang; Xian-Bo Deng; Chuan-Sheng Zheng
Journal:  Neuroradiology       Date:  2020-08-13       Impact factor: 2.804

8.  The Value of PETRA in Pulmonary Nodules of <3 cm Among Patients With Lung Cancer.

Authors:  Hui Feng; Gaofeng Shi; Hui Liu; Yu Du; Ning Zhang; Yaning Wang
Journal:  Front Oncol       Date:  2021-05-18       Impact factor: 6.244

9.  Comparison of Silent and Conventional MR Imaging for the Evaluation of Myelination in Children.

Authors:  Chisato Matsuo-Hagiyama; Yoshiyuki Watanabe; Hisashi Tanaka; Hiroto Takahashi; Atsuko Arisawa; Eri Yoshioka; Shin Nabatame; Sayaka Nakano; Noriyuki Tomiyama
Journal:  Magn Reson Med Sci       Date:  2016-10-31       Impact factor: 2.471

10.  Gradient-Modulated PETRA MRI.

Authors:  Naoharu Kobayashi; Ute Goerke; Luning Wang; Jutta Ellermann; Gregory J Metzger; Michael Garwood
Journal:  Tomography       Date:  2015-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.