Dariusz Noll1, Mariusz Kruk2, Jerzy Pręgowski3, Edyta Kaczmarska2, Karolina Kryczka2, Radosław Pracoń2, Mirosław Skwarek2, Zofia Dzielińska2, Joanna Petryka2, Mateusz Spiewak2, Barbara Lubiszewska2, Bożena Norwa-Otto2, Maksymilian Opolski3, Adam Witkowski3, Marcin Demkow2, Witold Rużyłło1, Cezary Kępka2.
Abstract
INTRODUCTION: Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. AIM: To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS).Entities:
Keywords: computed tomography; coronary angiography; coronary artery disease; intravascular ultrasound
Year: 2013 PMID: 24570686 PMCID: PMC3915947 DOI: 10.5114/pwki.2013.34022
Source DB: PubMed Journal: Postepy Kardiol Interwencyjnej ISSN: 1734-9338 Impact factor: 1.426
Baseline characteristics
| Clinical characteristics | Prevalence/60 Mean ± SD |
|---|---|
| Hyperlipidemia | 55/60 |
| Hypertension | 52/60 |
| Family history of coronary disease | 16/60 |
| Diabetes | 16/60 |
| Smoking | 15/60 |
| Serum creatinine [µmol/l] | 87 ±19 |
| Height [cm] | 172 ±9 |
| Weight [kg] | 80 ±14 |
| Body mass index [kg/m2] | 27 ±4 |
| Calcium score | 433 ±353 |
| Scan parameters: | 115 ±9 |
SD – standard deviation
Comparison of the calcium characteristics as assessed with CTCA vs. IVUS
| Characteristics | Number, mean ± SD, total = 252 | ||
|---|---|---|---|
| CTCA | IVUS | Value of | |
| Separate calcium deposits |
| 1/2/3 | < 0.001 |
| Location |
| Superficial/mid/deep | < 0.001 |
| Calcium contacting/overlapping lumen |
| Contacting/overlapping | < 0.001 |
| Maximum calcium arc [°] | 52 ±35 | 83 ±54 | < 0.001 |
| Total calcium arc [°] | 61 ±44 | 90 ±56 | < 0.001 |
| Distance between opposite lumen wall and the calcium edge [mm] | 2.4 ±0.8 | 2.8 ±0.8 | < 0.001 |
| Lumen area [mm2] | 6.4 ±3.4 | 7.0 ±3.7 | < 0.001 |
| Maximum lumen diameter [mm] | 3.2 ±0.8 | 3.2 ±0.8 | 0.366 |
| Minimum lumen diameter [mm] | 2.3 ±0.7 | 2.6 ±0.7 | < 0.001 |
| Mean lumen diameter [mm] | 2.8 ±0.7 | 2.9 ±0.8 | < 0.001 |
| Lumen eccentricity index | 1.4 ±0.3 | 1.2 ±0.1 | < 0.001 |
Data presented as means (± standard deviation) and numbers for proportions. Values of p derived from χ2 and Student t-test for comparison of categorical and continuous data respectively
Fig. 1Bland-Altman plots and comparison of tertiles (± 2 SD) of relative (percent) differences between respective lumen and calcium parameters as assessed by intravascular ultrasound (IVUS) vs. computed tomography coronary angiography (CTCA): A – maximum calcium arch, B – total calcium arch, C – minimum lumen diameter D – maximum lumen diameter, E – mean diameter, F – minimum lumen area G – calcium-opposite wall distance, H – eccentricity index
Comparison of the calcium characteristics within their tertiles as assessed with CTCA versus IVUS
| IVUS characteristics | Tertiles, mean (range) for 1st/2nd/3rd | Value of |
|---|---|---|
| Maximum calcium arc [°] | 40 (15-55)/70 (56-85)/139 (86-360) | 0.537/< 0.001/< 0.001 |
| Total calcium arc [°] | 40 (15-56)/79 (58-105)/155 (110-360) | 0.265/< 0.001/< 0.001 |
| Distance between opposite lumen wall and the calcium edge [mm] | 2.0 (1.4-2.3)/2.7 (2.4-3.0)/3.7 (3.10-5.40) | 0.001/< 0.001/< 0.001 |
| Lumen area [mm2] | 3.7 (1.8-5.0)/6.0 (5.10-7.60)/11.2 (7.70-22.50) | 0.264/0.042/< 0.001 |
| Maximum lumen diameter [mm] | 2.4 (1.7-2.7)/3.0 (2.8-3.3)/4.1 (3.4-6.10) | 0.004/0.495/< 0.001 |
| Minimum lumen diameter [mm] | 1.9 (1.4-2.2)/2.5 (2.3-2.8)/3.4 (2.9-4.8) | 0.024/< 0.001/< 0.001 |
| Mean lumen diameter [mm] | 2.1 (1.6-2.5)/2.8 (2.6-3.1)/3.8 (3.2-5.4) | 0.528/0.001/< 0.001 |
| Lumen eccentricity index | 1.11 (1.00-1.16)/1.21 (1.17-1.27)/1.39 (1.28-1.72) | < 0.001/< 0.001/0.277 |