Literature DB >> 24563273

Computed tomography-based classification of axis vertebra: choice of screw placement.

Nupur Pruthi1, Rose Dawn, Yogitha Ravindranath, Tanmoy Kumar Maiti, Roopa Ravindranath, Mariamma Philip.   

Abstract

PURPOSE: The purpose of the study was to: (1) introduce a new CT-based parameter: free facet area and provide its normative data; (2) standardize the method of measuring isthmus width and height of the axis vertebra; (3) propose a new grading system to predict the difficulty in inserting transarticular and C2 pedicle screws.
METHODS: Spiral CT scans of 47 adult dry axis vertebrae were studied. The methods of measuring isthmus width, isthmus height and free facet area are described.
RESULTS: The mean isthmus width was 5.04 mm on the right side and 5.42 mm on the left side. The mean isthmus height was 5.21 mm on the right side and 5.45 mm on the left side. Mean free facet area was 61.23 % on the right side and 70.18 % on the left side. A novel grading system is proposed on the basis of these three parameters. As per this grading system, 40.4 % of the sides were found to be difficult for transarticular and 24.5 % sides for C2 pedicle screw insertion (total score 2, 3, 4). A Management protocol is suggested on the basis of the grading system.
CONCLUSION: Inserting a transarticular screw was more frequently difficult as compared to pedicle screw. A new CT-based parameter (free facet area) and an efficient grading have been proposed to help surgeons choose the appropriate screw options, appreciate the complex anatomy of this region and compare data across various studies.

Entities:  

Mesh:

Year:  2014        PMID: 24563273     DOI: 10.1007/s00586-014-3240-z

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  28 in total

1.  Anatomic study of the axis for surgical planning of transarticular screw fixation.

Authors:  Tamaki Igarashi; Shinichi Kikuchi; Katsuhiko Sato; Satoru Kayama; Koji Otani
Journal:  Clin Orthop Relat Res       Date:  2003-03       Impact factor: 4.176

2.  Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation.

Authors:  Hiroshi Kuroki; Setti S Rengachary; Vijay K Goel; Scott A Holekamp; Ville Pitkänen; Nabil A Ebraheim
Journal:  Neurosurgery       Date:  2005-01       Impact factor: 4.654

3.  Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.

Authors:  Makoto Yoshida; Masashi Neo; Shunsuke Fujibayashi; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2006-07-01       Impact factor: 3.468

4.  Posterior C2 instrumentation: accuracy and complications associated with four techniques.

Authors:  Richard J Bransford; Anthony J Russo; Mark Freeborn; Quynh T Nguyen; Michael J Lee; Jens R Chapman; Carlo Bellabarba
Journal:  Spine (Phila Pa 1976)       Date:  2011-06-15       Impact factor: 3.468

5.  Osseous and vascular anatomical variations within the C1-C2 complex: a radiographical study using computed tomography angiography.

Authors:  Parham Moftakhar; Nestor R Gonzalez; Larry T Khoo; Langston T Holly
Journal:  Int J Med Robot       Date:  2008-06       Impact factor: 2.547

6.  Atlanto-axial fusion with transarticular screw fixation.

Authors:  D Grob; B Jeanneret; M Aebi; T M Markwalder
Journal:  J Bone Joint Surg Br       Date:  1991-11

7.  Posterior stabilization with an interlaminar clamp in cervical injuries: technical note and review of the long term experience with the method.

Authors:  R O Holness; W S Huestis; W J Howes; R A Langille
Journal:  Neurosurgery       Date:  1984-03       Impact factor: 4.654

8.  Plate and screw fixation for atlanto-axial subluxation.

Authors:  A Goel; V Laheri
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

9.  Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study.

Authors:  Francesco Cacciola; Umesh Phalke; Atul Goel
Journal:  Neurol India       Date:  2004-06       Impact factor: 2.117

10.  Atlantoaxial and craniocervical arthrodesis in children: a tomographic study comparing suitability of C2 pedicles and C2 laminae for screw fixation.

Authors:  Fábio Ferri-de-Barros; David G Little; Corinne Bridge; John Cummine; Andrew K Cree
Journal:  Spine (Phila Pa 1976)       Date:  2010-02-01       Impact factor: 3.468

View more
  5 in total

Review 1.  Anatomical variations of the foramen transversarium in cervical vertebrae: findings, review of the literature, and clinical significance during cervical spine surgery.

Authors:  Aristeidis H Zibis; Vasileios Mitrousias; Kyriaki Baxevanidou; Michael Hantes; Theofilos Karachalios; Dimitrios Arvanitis
Journal:  Eur Spine J       Date:  2016-08-23       Impact factor: 3.134

2.  Axis vertebral dimensions for safe screw placement: A CT normative data analysis.

Authors:  Vibisha Pragash; Balaji Douraiswami; Suresh Subramani
Journal:  J Clin Orthop Trauma       Date:  2020-06-18

3.  Radiologic Analysis of C2 to Predict Safe Placement of Pedicle Screws.

Authors:  Rex A W Marco; Christopher I Phelps; Rebecca C Kuo; W U Zhuge; Clinton W Howard; Vivek P Kushwaha; Derek T Bernstein
Journal:  Int J Spine Surg       Date:  2018-03-30

4.  Morphometric and radiological assessments of dimensions of Axis in dry vertebrae: A study in Indian population.

Authors:  Raman Mohan Sharma; Nupur Pruthi; Paritosh Pandey; Rose Dawn; Yogitha Ravindranath; Roopa Ravindranath
Journal:  Indian J Orthop       Date:  2015 Nov-Dec       Impact factor: 1.251

5.  Can the position of the vertebral artery be predicted on a lateral view X-ray of the craniovertebral junction? A radiological anatomy study.

Authors:  Nupur Pruthi; Lokesh Nehete; Tanmoy Maity; Rose Dawn; Yogita Ravindranath; Roopa Ravindranath; Mariamma Philips
Journal:  Surg Neurol Int       Date:  2018-06-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.