A single-session testing protocol to determine critical power and W'.

Keren Constantini1, Surendran Sabapathy, Troy J Cross.   

Abstract

PURPOSE: Critical power (CP), and the finite capacity to perform work above CP (W'), can be determined using a 3-min "all-out" cycling test (3MT). This protocol requires two laboratory visits: an incremental exercise test, followed by a 3MT on a separate day. The purpose of this study was to establish whether an incremental exercise test and a 3MT performed during a single laboratory visit can be used to accurately determine CP and W'.
METHODS: Twelve participants completed two experimental protocols: (1) Combined protocol: an incremental exercise test followed by a 3MT, with 20 min of recovery between exercise bouts; and (2) Independent protocol: the conventional 3MT protocol, performed on a separate day.
RESULTS: CP determined from the Combined (254 ± 117 W) and Independent (256 ± 118 W) protocols were not different (p = 0.40). Similarly, W' was not different (p = 0.96) between the Combined (13.7 ± 3.9 kJ) and Independent (13.7 ± 4.5 kJ) protocols. Linear regression revealed a strong level of measurement agreement between the protocols for CP and W', evidenced by high R(2) values (≥0.85) and marginal standard errors of the estimates (CP = 5 W; W' = 1.81 kJ).
CONCLUSION: A Combined protocol, consisting of an incremental exercise test followed by a 3MT, provides an accurate and valid method to determine an individual's CP and, to a lesser extent, W'. Furthermore, this protocol permits the measurement of the gas-exchange threshold and peak O2 uptake and, consequently, the moderate, heavy, and severe exercise-intensity domains may be defined within a single exercise-testing session.

Entities:  

Mesh:

Year:  2014        PMID: 24563054     DOI: 10.1007/s00421-014-2827-8

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  40 in total

Review 1.  The effect of endurance training on parameters of aerobic fitness.

Authors:  A M Jones; H Carter
Journal:  Sports Med       Date:  2000-06       Impact factor: 11.136

2.  Critical power as an endurance index.

Authors:  J F Vautier; H Vandewalle; H Arabi; H Monod
Journal:  Appl Ergon       Date:  1995-04       Impact factor: 3.661

3.  A 3-min all-out test to determine peak oxygen uptake and the maximal steady state.

Authors:  Mark Burnley; Jonathan H Doust; Anni Vanhatalo
Journal:  Med Sci Sports Exerc       Date:  2006-11       Impact factor: 5.411

4.  Robustness of a 3 min all-out cycling test to manipulations of power profile and cadence in humans.

Authors:  Anni Vanhatalo; Jonathan H Doust; Mark Burnley
Journal:  Exp Physiol       Date:  2007-10-19       Impact factor: 2.969

5.  Determination of critical power using a 3-min all-out cycling test.

Authors:  Anni Vanhatalo; Jonathan H Doust; Mark Burnley
Journal:  Med Sci Sports Exerc       Date:  2007-03       Impact factor: 5.411

6.  Maximal oxygen uptake in athletes.

Authors:  B Saltin; P O Astrand
Journal:  J Appl Physiol       Date:  1967-09       Impact factor: 3.531

Review 7.  Critical power: implications for determination of V˙O2max and exercise tolerance.

Authors:  Andrew M Jones; Anni Vanhatalo; Mark Burnley; R Hugh Morton; David C Poole
Journal:  Med Sci Sports Exerc       Date:  2010-10       Impact factor: 5.411

8.  DETERMINATION OF CRITICAL POWER AND ANAEROBIC WORK CAPACITY: IS ONE TEST BETTER THAN TWO?

Authors:  Troy J Cross
Journal:  J Strength Cond Res       Date:  2016-05       Impact factor: 3.775

Review 9.  The critical power concept. A review.

Authors:  D W Hill
Journal:  Sports Med       Date:  1993-10       Impact factor: 11.136

10.  Time required for the restoration of normal heavy exercise VO2 kinetics following prior heavy exercise.

Authors:  Mark Burnley; Jonathan H Doust; Andrew M Jones
Journal:  J Appl Physiol (1985)       Date:  2006-07-20
View more
  6 in total

1.  Critical power: what is being measured and why?

Authors:  Raffy Dotan
Journal:  Eur J Appl Physiol       Date:  2014-07-27       Impact factor: 3.078

2.  A 'ramp-sprint' protocol to characterise indices of aerobic function and exercise intensity domains in a single laboratory test.

Authors:  Scott R Murgatroyd; Lindsey A Wylde; Daniel T Cannon; Susan A Ward; Harry B Rossiter
Journal:  Eur J Appl Physiol       Date:  2014-06-03       Impact factor: 3.078

Review 3.  Determination of Critical Power Using Different Possible Approaches among Endurance Athletes: A Review.

Authors:  Lucie Lipková; Michal Kumstát; Ivan Struhár
Journal:  Int J Environ Res Public Health       Date:  2022-06-21       Impact factor: 4.614

Review 4.  A critical review of critical power.

Authors:  Raffy Dotan
Journal:  Eur J Appl Physiol       Date:  2022-03-18       Impact factor: 3.346

5.  Determinants of curvature constant (W') of the power duration relationship under normoxia and hypoxia: the effect of pre-exercise alkalosis.

Authors:  Sanjoy K Deb; Lewis A Gough; S Andy Sparks; Lars R McNaughton
Journal:  Eur J Appl Physiol       Date:  2017-03-09       Impact factor: 3.078

6.  The ramp and all-out exercise test to determine critical power: validity and robustness to manipulations in body position.

Authors:  Richie P Goulding; Denise M Roche; Simon Marwood
Journal:  Eur J Appl Physiol       Date:  2021-06-18       Impact factor: 3.078

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.