Literature DB >> 24557775

Use of true net power in intraocular lens power calculations in eyes with prior myopic laser refractive surgery.

Andreas Frings1, Veronika Hold, Gernot Steinwender, Yosuf El-Shabrawi, Navid Ardjomand.   

Abstract

Intraocular lens (IOL) power calculation following laser refractive surgery is still one of the most challenging aspects in cataract surgery. This study was initiated to investigate the application of true net power (TNP; Pentacam, software version 6.02r10, Oculus, Germany) in IOL power calculations in eyes with prior laser refractive surgery. Our data contribute to the notion that the TNP of the Pentacam is a reliable alternative to determine the IOL power in cases where the historical data are missing. Based on our data, we recommend implementing the TNP to obtain the true corneal power and thus, reliable IOL power calculations.

Entities:  

Mesh:

Year:  2014        PMID: 24557775     DOI: 10.1007/s10792-014-9916-x

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  12 in total

Review 1.  Intraocular lens calculations status after corneal refractive surgery.

Authors:  B Seitz; A Langenbucher
Journal:  Curr Opin Ophthalmol       Date:  2000-02       Impact factor: 3.761

2.  A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis.

Authors:  Sergio Sónego-Krone; Gerson López-Moreno; Oscar V Beaujon-Balbi; Carlos G Arce; Paulo Schor; Mauro Campos
Journal:  Arch Ophthalmol       Date:  2004-02

3.  Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula.

Authors:  Edmondo Borasio; Julian Stevens; Guy T Smith
Journal:  J Cataract Refract Surg       Date:  2006-12       Impact factor: 3.351

4.  Challenges and approaches in modern biometry and IOL calculation.

Authors:  Wolfgang Haigis
Journal:  Saudi J Ophthalmol       Date:  2012-01

5.  Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

Authors:  Qiongyan Tang; Kenneth J Hoffer; Michael D Olson; Kevin M Miller
Journal:  J Cataract Refract Surg       Date:  2009-07       Impact factor: 3.351

6.  Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula.

Authors:  Wolfgang Haigis
Journal:  J Cataract Refract Surg       Date:  2008-10       Impact factor: 3.351

7.  Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery.

Authors:  Jack T Holladay; Warren E Hill; Andreas Steinmueller
Journal:  J Refract Surg       Date:  2009-10-12       Impact factor: 3.573

8.  Intraocular lens power calculation after myopic refractive surgery: theoretical comparison of different methods.

Authors:  Giacomo Savini; Piero Barboni; Maurizio Zanini
Journal:  Ophthalmology       Date:  2006-06-12       Impact factor: 12.079

9.  [Visual function with blue light filter IOLs].

Authors:  C Wohlfart; K Tschuschnig; P Fellner; K Weiss; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Klin Monbl Augenheilkd       Date:  2007-01       Impact factor: 0.700

10.  Laser-assisted subepithelial keratomileusis with mitomycin C for myopic astigmatism ≥2.00 diopters using a Zeiss MEL 80 Excimer.

Authors:  A Frings; B Vidic; Y El-Shabrawi; N Ardjomand
Journal:  Int Ophthalmol       Date:  2013-06-29       Impact factor: 2.031

View more
  3 in total

1.  Spectacle Independence after Cataract Extraction in Post-Radial Keratotomy Patients Using Hybrid Monovision with ReSTOR(®) Multifocal and TECNIS(®) Monofocal Intraocular Lenses.

Authors:  Isha Gupta; Zack Oakey; Faisal Ahmed; Balamurali K Ambati
Journal:  Case Rep Ophthalmol       Date:  2014-05-22

2.  Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report.

Authors:  Raffaele Nuzzi; Francesca Monteu; Federico Tridico
Journal:  Case Rep Ophthalmol       Date:  2017-08-29

3.  Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation.

Authors:  Mohammad Ghoreyshi; Ahmadreza Khalilian; Mohammadreza Peyman; Mohaddeseh Mohammadinia; Alireza Peyman
Journal:  J Curr Ophthalmol       Date:  2017-10-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.