Literature DB >> 19545808

Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

Qiongyan Tang1, Kenneth J Hoffer, Michael D Olson, Kevin M Miller.   

Abstract

PURPOSE: To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK).
SETTING: Jules Stein Eye Institute, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, California, USA.
METHODS: In this combined retrospective and prospective clinical study, patients who had cataract surgery after corneal refractive surgery were recalled to have Scheimpflug imaging of the operated cornea and Holladay EKR determination. The Holladay EKR was compared with a gold-standard K value, which was the back-calculated value using the original Hoffer formula based on the actual surgical outcomes. Eyes without a history of refractive surgery served as controls.
RESULTS: Twenty-seven patients (41 eyes) were evaluated; 26 eyes had previous LASIK or PRK and 15, previous RK. Forty-one eyes served as controls. The mean error of the Holladay EKR in eyes with previous LASIK or PRK was +1.84 diopters (D) (range +0.66 to +4.94 D). The mean error in eyes with previous RK was +2.17 D (range +0.48 to +3.09 D). In the control eyes, the mean EKR error was +1.38 D (range -0.17 to +2.54 D).
CONCLUSIONS: The Holladay EKR calculated using version 1.16r04 of the Scheimpflug system software was inaccurate in virgin corneas and in those with a history of LASIK, PRK, or RK using current IOL power calculation formulas. The Scheimpflug power measurements were consistently steeper than the true corneal power.

Entities:  

Mesh:

Year:  2009        PMID: 19545808     DOI: 10.1016/j.jcrs.2009.02.030

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Predictability of Sirius dual-scanning corneal tomography in the measurement of corneal power after photorefractive surgery.

Authors:  Sameh M Fouda; Haitham Y Al-Nashar; Basem M Ibrahim; Ashraf Bor'i
Journal:  Int Ophthalmol       Date:  2015-05-19       Impact factor: 2.031

2.  Use of true net power in intraocular lens power calculations in eyes with prior myopic laser refractive surgery.

Authors:  Andreas Frings; Veronika Hold; Gernot Steinwender; Yosuf El-Shabrawi; Navid Ardjomand
Journal:  Int Ophthalmol       Date:  2014-02-21       Impact factor: 2.031

Review 3.  Clinically relevant biometry.

Authors:  Afsun Sahin; Pedram Hamrah
Journal:  Curr Opin Ophthalmol       Date:  2012-01       Impact factor: 3.761

4.  Intraocular lens power calculation in patients with irregular astigmatism.

Authors:  Asaf Achiron; Omar Elhaddad; Duncan Leadbetter; Eliya Levinger; Oleksiy Voytsekhivskyy; Katy Smith; Venkata Avadhanam; Kieren Darcy; Derek Tole
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-01       Impact factor: 3.117

5.  Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

Authors:  Kaevalin Lekhanont; Manachai Nonpassopon; Khemruetai Wannarosapark; Varintorn Chuckpaiwong
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

6.  An Analysis of Scheimpflug Holladay-Equivalent Keratometry Readings Following Corneal Collagen Cross-Linking.

Authors:  Ayhan Saglik; Hakim Celik; Mustafa Aksoy
Journal:  Beyoglu Eye J       Date:  2019-08-08

7.  Comparison of Anterior Segment Biometric Measurements between Pentacam HR and IOLMaster in Normal and High Myopic Eyes.

Authors:  Jing Dong; Maolong Tang; Yaqin Zhang; Yading Jia; Haining Zhang; Zhijie Jia; Xiaogang Wang
Journal:  PLoS One       Date:  2015-11-17       Impact factor: 3.240

8.  Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

Authors:  Hany A Helaly; Mohammad A M El-Hifnawy; Mohamed Shafik Shaheen; Amr F Abou El-Kheir
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar

9.  Evaluation of Equivalent Keratometry Readings Obtained by Pentacam HR (High Resolution).

Authors:  Yanjun Hua; Xiaolan Zhang; Tor Paaske Utheim; Jinhai Huang; Chao Pan; Weina Tan; Qinmei Wang
Journal:  PLoS One       Date:  2016-03-07       Impact factor: 3.240

10.  Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach.

Authors:  Michele Lanza; Robert Koprowski; Mario Bifani Sconocchia
Journal:  Biomed Eng Online       Date:  2018-08-13       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.