Literature DB >> 1442477

Effects of intraaortic balloon pumping on coronary hemodynamics after coronary angioplasty in patients with acute myocardial infarction.

M Ishihara1, H Sato, H Tateishi, T Kawagoe, Y Muraoka, M Yoshimura.   

Abstract

It has been reported that intraaortic balloon pumping can prevent reocclusion after coronary angioplasty for acute myocardial infarction. The speculated mechanism has been the production of markedly enhanced diastolic coronary perfusion pressure; however, most studies have reported that intraaortic balloon pumping has little effect on coronary blood flow. To assess the effectiveness of this procedure, we studied 12 patients with acute anterior myocardial infarction who were undergoing coronary angioplasty and intraaortic balloon pumping. After successful angioplasty, coronary blood flow velocity was measured with a coronary Doppler catheter before and during intraaortic balloon pumping. Although mean coronary blood flow velocity was unchanged, intraaortic balloon pumping increased peak coronary blood flow velocity from 34.6 +/- 5.0 cm/sec (mean +/- SEM) to 46.7 +/- 5.8 cm/sec (p < 0.005). Such an increase in peak coronary blood flow velocity seemed to be a mechanism by which intraaortic balloon pumping could prevent reocclusion after coronary angioplasty for acute myocardial infarction.

Entities:  

Mesh:

Year:  1992        PMID: 1442477     DOI: 10.1016/0002-8703(92)90391-8

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  5 in total

1.  Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy.

Authors:  Stephen R Carnahan; Steven C Koenig; Michael A Sobieski; Erin M Schumer; Gretel Monreal; Yu Wang; Young Choi; Brek J Meuris; Landon H Tompkins; Zhongjun J Wu; Mark S Slaughter; Guruprasad A Giridharan
Journal:  ASAIO J       Date:  2017 Mar/Apr       Impact factor: 2.872

Review 2.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

3.  Percutaneous cardiopulmonary support in refractory no-reflow with cardiogenic shock after coronary stenting in acute myocardial infarction.

Authors:  Jung-Woo Son; Jin-Sun Kim; Jung Myung Lee; Sung Jin Hong; Min Kyu Jung; Duk-Hwan Kim; Jung-Sun Kim; Donghoon Choi; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2010-07       Impact factor: 2.759

4.  Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function.

Authors:  Steven C Koenig; Kenneth N Litwak; Guruprasad A Giridharan; George M Pantalos; Robert D Dowling; Sumanth D Prabhu; Mark S Slaughter; Michael A Sobieski; Paul A Spence
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

5.  Impact of intra-aortic balloon pump on long-term mortality of unselected patients with ST-segment elevation myocardial infarction complicated by cardiogenic shock.

Authors:  Artur Dziewierz; Zbigniew Siudak; Tomasz Rakowski; Paweł Kleczyński; Wojciech Zasada; Dariusz Dudek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2014-09-11       Impact factor: 1.426

  5 in total