Literature DB >> 19093060

Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection.

Daniela Garcia Ribeiro1, Ana Cláudia Pavarina, Ana Lucia Machado, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani.   

Abstract

OBJECTIVES: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). METHOD AND MATERIALS: For each material, 48 specimens (64 x 10 x 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05).
RESULTS: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group.
CONCLUSION: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19093060

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  5 in total

1.  Effect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.

Authors:  Jagadish Konchada; Suma Karthigeyan; Syed Asharaf Ali; Venkateshwaran R; Ramesh Amirisetty; Anurag Dani
Journal:  J Clin Diagn Res       Date:  2013-12-15

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

3.  Flexural strength of hydrogen plasma-treated polypropylene fiber-reinforced polymethyl methacrylate denture base material.

Authors:  Merin Mathew; Kamalakanth Shenoy; K S Ravishankar
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  Ethanol postpolymerization treatment for improving the biocompatibility of acrylic reline resins.

Authors:  Cristina B Neves; Luís P Lopes; Helena F Ferrão; Joana P Miranda; Matilde F Castro; Ana F Bettencourt
Journal:  Biomed Res Int       Date:  2013-07-18       Impact factor: 3.411

5.  Effect of Repeated Microwave Disinfection on the Surface Hardness of a Heat-Cured Denture Base Resin: An In vitro Study.

Authors:  Priti Jaiswal; Neelam Pande; Rajlakshmi Banerjee; Usha Radke
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep