Literature DB >> 24551395

Evaluation of intravenous medication errors with smart infusion pumps in an academic medical center.

Kumiko Ohashi1, Patricia Dykes2, Kathleen McIntosh3, Elizabeth Buckley3, Matt Wien4, David W Bates1.   

Abstract

While some published research indicates a fairly high frequency of Intravenous (IV) medication errors associated with the use of smart infusion pumps, the generalizability of these results are uncertain. Additionally, the lack of a standardized methodology for measuring these errors is an issue. In this study we iteratively developed a web-based data collection tool to capture IV medication errors using a participatory design approach with interdisciplinary experts. Using the developed tool, a prevalence study was then conducted in an academic medical center. The results showed that the tool was easy to use and effectively captured all IV medication errors. Through the prevalence study, violation errors of hospital policy were found that could potentially place patients at risk, but no critical errors known to contribute to patient harm were noted.

Entities:  

Mesh:

Year:  2013        PMID: 24551395      PMCID: PMC3900131     

Source DB:  PubMed          Journal:  AMIA Annu Symp Proc        ISSN: 1559-4076


  11 in total

1.  Ethnographic study of incidence and severity of intravenous drug errors.

Authors:  Katja Taxis; Nick Barber
Journal:  BMJ       Date:  2003-03-29

2.  Some unintended consequences of information technology in health care: the nature of patient care information system-related errors.

Authors:  Joan S Ash; Marc Berg; Enrico Coiera
Journal:  J Am Med Inform Assoc       Date:  2003-11-21       Impact factor: 4.497

3.  The data page. The cause + effect of medication errors.

Authors:  Lee Ann Runy
Journal:  Hosp Health Netw       Date:  2004-04

4.  Effect of bar-code technology on the safety of medication administration.

Authors:  Eric G Poon; Carol A Keohane; Catherine S Yoon; Matthew Ditmore; Anne Bane; Osnat Levtzion-Korach; Thomas Moniz; Jeffrey M Rothschild; Allen B Kachalia; Judy Hayes; William W Churchill; Stuart Lipsitz; Anthony D Whittemore; David W Bates; Tejal K Gandhi
Journal:  N Engl J Med       Date:  2010-05-06       Impact factor: 91.245

5.  Insights from the sharp end of intravenous medication errors: implications for infusion pump technology.

Authors:  M Husch; C Sullivan; D Rooney; C Barnard; M Fotis; J Clarke; G Noskin
Journal:  Qual Saf Health Care       Date:  2005-04

6.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

7.  Intravenous medication safety and smart infusion systems: lessons learned and future opportunities.

Authors:  Carol A Keohane; Judy Hayes; Catherine Saniuk; Jeffrey M Rothschild; David W Bates
Journal:  J Infus Nurs       Date:  2005 Sep-Oct

8.  Intravenous medication safety system averts high-risk medication errors and provides actionable data.

Authors:  Marianne Fields; Judy Peterman
Journal:  Nurs Adm Q       Date:  2005 Jan-Mar

9.  Relationship between medication errors and adverse drug events.

Authors:  D W Bates; D L Boyle; M B Vander Vliet; J Schneider; L Leape
Journal:  J Gen Intern Med       Date:  1995-04       Impact factor: 5.128

10.  Systems analysis of adverse drug events. ADE Prevention Study Group.

Authors:  L L Leape; D W Bates; D J Cullen; J Cooper; H J Demonaco; T Gallivan; R Hallisey; J Ives; N Laird; G Laffel
Journal:  JAMA       Date:  1995-07-05       Impact factor: 56.272

View more
  8 in total

Review 1.  Benefits and risks of using smart pumps to reduce medication error rates: a systematic review.

Authors:  Kumiko Ohashi; Olivia Dalleur; Patricia C Dykes; David W Bates
Journal:  Drug Saf       Date:  2014-12       Impact factor: 5.606

2.  A Multi-hospital Before-After Observational Study Using a Point-Prevalence Approach with an Infusion Safety Intervention Bundle to Reduce Intravenous Medication Administration Errors.

Authors:  Kumiko O Schnock; Patricia C Dykes; Jennifer Albert; Deborah Ariosto; Caitlin Cameron; Diane L Carroll; Moreen Donahue; Adrienne G Drucker; Rosemary Duncan; Linda Fang; Marla Husch; Nicole McDonald; Ray R Maddox; Julie McGuire; Sally Rafie; Emilee Robertson; Melinda Sawyer; Elizabeth Wade; Catherine S Yoon; Stuart Lipsitz; David W Bates
Journal:  Drug Saf       Date:  2018-06       Impact factor: 5.606

3.  Quantifying the Impact of Infusion Alerts and Alarms on Nursing Workflows: A Retrospective Analysis.

Authors:  Denny Yu; Marian Obuseh; Poching DeLaurentis
Journal:  Appl Clin Inform       Date:  2021-06-30       Impact factor: 2.762

4.  Nurse and Pharmacist Knowledge of Intravenous Smart Pump System Setup Requirements.

Authors:  Karen K Giuliano; Jeannine W C Blake
Journal:  Biomed Instrum Technol       Date:  2021-01-01

5.  User-testing guidelines to improve the safety of intravenous medicines administration: a randomised in situ simulation study.

Authors:  Matthew D Jones; Anita McGrogan; D K Raynor; Margaret C Watson; Bryony Dean Franklin
Journal:  BMJ Qual Saf       Date:  2020-06-30       Impact factor: 7.035

6.  Intravenous Smart Pumps During Actual Clinical Use: A Descriptive Comparison of Primary and Secondary Infusion Practices.

Authors:  Karen K Giuliano; Daleen Penoyer; Rebecca S Mahuren; Melody Bennett
Journal:  J Infus Nurs       Date:  2021 May-Jun 01

7.  Intravenous Smart Pumps at the Point of Care: A Descriptive, Observational Study.

Authors:  Karen K Giuliano; Jeannine W C Blake; Nancy Phoenix Bittner; Vicki Gamez; Robert Butterfield
Journal:  J Patient Saf       Date:  2022-08-06       Impact factor: 2.243

Review 8.  Incidence and prevalence of intravenous medication errors in the UK: a systematic review.

Authors:  Adam Sutherland; Michela Canobbio; Janine Clarke; Michelle Randall; Tom Skelland; Emma Weston
Journal:  Eur J Hosp Pharm       Date:  2018-10-23
  8 in total