Literature DB >> 24531937

Poor outcome of a spherical pressfit cup with a modern ceramic liner: a prospective cohort study of 181 cups.

Thomas Ilchmann1, Lukas Zwicky, Silke Gersbach, Martin Clauss.   

Abstract

A spherical pressfit cup with a new ceramic liner was introduced in a clinical trial in order to improve range of motion and reduce wear induced problems. The early clinical and radiological outcome was assessed.In a prospective cohort study 181 hips received a seleXys TH+ cup (Mathys, Bettlach, Switzerland) in combination with a third generation ceramic liner (ceramys, Mathys, Bettlach, Switzerland). The Harris Hip Score (HHS), pain (VAS) and range of motion (ROM) were recorded, cup migration and inclination were measured. Experience of any noise was documented.Fourteen hips were radiologically loose, seven of them were revised. Two-year survival of the cup was 92% with radiological loosening as the endpoint. There was no correlation between head size and ROM, no patient had a dislocation. There were no ceramic fractures. Two patients experienced squeaking and three clicking at final follow-up.Reasons for loosening might have been multifactorial but the rate of failure was unacceptably high. The use of large heads did not improve the ROM and development of noise could not be prevented with the modern ceramic. We abandoned the use of this implant system.

Entities:  

Mesh:

Year:  2014        PMID: 24531937     DOI: 10.5301/hipint.5000130

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  Comment to "Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up".

Authors:  Zhi-Qiang Fan; Xin Xu
Journal:  Int Orthop       Date:  2021-03-16       Impact factor: 3.075

2.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

3.  Midterm analysis of the seleXys cup with ceramic inlay.

Authors:  Tamas Halasi; David Kieser; Christopher M A Frampton; Gary J Hooper
Journal:  Arthroplast Today       Date:  2016-11-09

4.  Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up.

Authors:  J van Loon; A M J S Vervest; H M van der Vis; I N Sierevelt; D C Baas; K T M Opdam; G M M J Kerkhoffs; D Haverkamp
Journal:  Int Orthop       Date:  2021-01-18       Impact factor: 3.075

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.