Literature DB >> 24529470

Finite element modeling of soft tissues: material models, tissue interaction and challenges.

Maren Freutel1, Hendrik Schmidt2, Lutz Dürselen3, Anita Ignatius3, Fabio Galbusera4.   

Abstract

BACKGROUND: Musculoskeletal soft tissues, such as articular cartilage, ligaments, knee meniscus and intervertebral disk, have a complex structure, which provides elasticity and capability to support and distribute the body loads. Soft tissues describe an inhomogeneous and multiphasic structure, and exhibit a nonlinear, time-dependent behavior. Their mechanical response is governed by a substance composed of protein fiber-rich and proteoglycan-rich extracellular matrix and interstitial fluid. Protein fibers (e.g. collagen) give the tissue direction dependent stiffness and strength. To investigate these complex biological systems, the use of mathematical tools is well established, alone or in combination with experimental in vitro and in vivo tests. However, the development of these models poses many challenges due to the complex structure and mechanical response of soft tissues.
METHODS: Non-systematic literature review.
FINDINGS: This paper provides a summary of different modeling strategies with associated material properties, contact interactions between articulating tissues, validation and sensitivity of soft tissues with special focus on knee joint soft tissues and intervertebral disk. Furthermore, it reviews and discusses some salient clinical findings of reported finite element simulations.
INTERPRETATION: Model studies extensively contributed to the understanding of functional biomechanics of soft tissues. Models can be effectively used to elucidate clinically relevant questions. However, users should be aware of the complexity of such tissues and of the capabilities and limitations of these approaches to adequately simulate a specific in vivo or in vitro phenomenon.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anisotropy; Biomechanics; Cartilage; Finite element; Intervertebral disk; Material formulations; Meniscus; Soft tissue

Mesh:

Substances:

Year:  2014        PMID: 24529470     DOI: 10.1016/j.clinbiomech.2014.01.006

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  26 in total

1.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

2.  A new ChainMail approach for real-time soft tissue simulation.

Authors:  Jinao Zhang; Yongmin Zhong; Julian Smith; Chengfan Gu
Journal:  Bioengineered       Date:  2016-07-03       Impact factor: 3.269

Review 3.  Biomedical soft robots: current status and perspective.

Authors:  T Ashuri; A Armani; R Jalilzadeh Hamidi; T Reasnor; S Ahmadi; K Iqbal
Journal:  Biomed Eng Lett       Date:  2020-05-28

4.  An eFace-Template Method for Efficiently Generating Patient-Specific Anatomically-Detailed Facial Soft Tissue FE Models for Craniomaxillofacial Surgery Simulation.

Authors:  Xiaoyan Zhang; Zhen Tang; Michael A K Liebschner; Daeseung Kim; Shunyao Shen; Chien-Ming Chang; Peng Yuan; Guangming Zhang; Jaime Gateno; Xiaobo Zhou; Shao-Xiang Zhang; James J Xia
Journal:  Ann Biomed Eng       Date:  2015-10-13       Impact factor: 3.934

5.  A Finite Element Algorithm for Large Deformation Biphasic Frictional Contact Between Porous-Permeable Hydrated Soft Tissues.

Authors:  Brandon K Zimmerman; Steve A Maas; Jeffrey A Weiss; Gerard A Ateshian
Journal:  J Biomech Eng       Date:  2022-02-01       Impact factor: 2.097

6.  Displacement voxelization to resolve mesh-image mismatch: Application in deriving dense white matter fiber strains.

Authors:  Songbai Ji; Wei Zhao
Journal:  Comput Methods Programs Biomed       Date:  2021-11-13       Impact factor: 5.428

7.  Hydroxysafflor Yellow A (HSYA) Protects Endplate Chondrocytes Against IL-1β-Induced Injury Through Promoting Autophagy.

Authors:  Zongyu Zhang; Yongfeng Huo; Zhijing Zhou; Peng Zhang; Jun Hu
Journal:  Evid Based Complement Alternat Med       Date:  2022-07-04       Impact factor: 2.650

8.  An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

Authors:  Xiaoyan Zhang; Daeseung Kim; Shunyao Shen; Peng Yuan; Siting Liu; Zhen Tang; Guangming Zhang; Xiaobo Zhou; Jaime Gateno; Michael A K Liebschner; James J Xia
Journal:  Biomech Model Mechanobiol       Date:  2017-10-12

9.  Prediction of patellofemoral joint kinematics and contact through co-simulation of rigid body dynamics and nonlinear finite element analysis.

Authors:  Jacobus H Müller; Swithin Razu; Ahmet Erdemir; Trent M Guess
Journal:  Comput Methods Biomech Biomed Engin       Date:  2020-05-07       Impact factor: 1.763

10.  A Quasi-Static Quantitative Ultrasound Elastography Algorithm Using Optical Flow.

Authors:  Raphael Lamprecht; Florian Scheible; Marion Semmler; Alexander Sutor
Journal:  Sensors (Basel)       Date:  2021-04-25       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.