Literature DB >> 24513469

Effectiveness of fluorography versus cineangiography at reducing radiation exposure during diagnostic coronary angiography.

Binita Shah1, Xingchen Mai2, Lakshmi Tummala2, Chad Kliger3, Sripal Bangalore2, Louis H Miller2, Steven P Sedlis4, Frederick Feit2, Michael Liou2, Michael Attubato2, John Coppola2, James Slater2.   

Abstract

Coronary angiography is the gold standard for defining obstructive coronary disease. However, radiation exposure remains an unwanted hazard. Patients referred for coronary angiography with abdominal circumference<45 inches and glomerular filtration rate>60 ml/min were randomized to the fluorography (n=25) or cineangiography (n=25) group. Patients in the fluorography group underwent coronary angiography using retrospectively stored fluorography with repeat injection under cineangiography only when needed for better resolution per operator's discretion. Patients in the cineangiography group underwent coronary angiography using routine cineangiography. The primary end point was patient radiation exposure measured by radiochromic film. Secondary end points included the radiation output measurement of kerma-area product and air kerma at the interventional reference point (Ka,r) and operator radiation exposure measured by a dosimeter. Patient radiation exposure (158.2 mGy [76.5 to 210.2] vs 272.5 mGy [163.3 to 314.0], p=0.001), kerma-area product (1,323 μGy·m2 [826 to 1,765] vs 3,451 μGy·m2 [2,464 to 4,818], p<0.001), and Ka,r (175 mGy [112 to 252] vs 558 mGy [313 to 621], p<0.001) were significantly lower in the fluorography compared with cineangiography group (42%, 62%, and 69% relative reduction, respectively). Operator radiation exposure trended in the same direction, although statistically nonsignificant (fluorography 2.35 μGy [1.24 to 6.30] vs cineangiography 5.03 μGy [2.48 to 7.80], p=0.059). In conclusion, the use of fluorography in a select group of patients during coronary angiography, with repeat injection under cineangiography only when needed, was efficacious at reducing patient radiation exposure.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24513469      PMCID: PMC3959232          DOI: 10.1016/j.amjcard.2013.12.013

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

Review 1.  Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury.

Authors:  T R Koenig; D Wolff; F A Mettler; L K Wagner
Journal:  AJR Am J Roentgenol       Date:  2001-07       Impact factor: 3.959

2.  Retrospective evaluation of occurrence of skin injuries in interventional cardiac procedures.

Authors:  R Padovani; G Bernardi; E Quai; M Signor; H S Toh; G Morocutti; L Spedicato
Journal:  Radiat Prot Dosimetry       Date:  2006-02-03       Impact factor: 0.972

3.  Effective doses for coronary angiography.

Authors:  K C Leung; C J Martin
Journal:  Br J Radiol       Date:  1996-05       Impact factor: 3.039

4.  Changes in the practice of percutaneous coronary intervention: a comparison of enrollment waves in the National Heart, Lung, and Blood Institute (NHLBI) Dynamic Registry.

Authors:  W K Laskey; D O Williams; H A Vlachos; H Cohen; D R Holmes; S B King; S F Kelsey; J Slater; D Faxon; M Al-Bassam; E Block; K M Detre
Journal:  Am J Cardiol       Date:  2001-04-15       Impact factor: 2.778

Review 5.  ICRP PUBLICATION 120: Radiological protection in cardiology.

Authors:  C Cousins; D L Miller; G Bernardi; M M Rehani; P Schofield; E Vañó; A J Einstein; B Geiger; P Heintz; R Padovani; K-H Sim
Journal:  Ann ICRP       Date:  2013-02

6.  Radiation exposure of patients and coronary arteries in the stent era: A prospective study.

Authors:  D Katritsis; E Efstathopoulos; S Betsou; S Korovesis; K Faulkner; G Panayiotakis; M M Webb-Peploe
Journal:  Catheter Cardiovasc Interv       Date:  2000-11       Impact factor: 2.692

Review 7.  Skin radiation injuries in patients following repeated coronary angioplasty procedures.

Authors:  E Vano; J Goicolea; C Galvan; L Gonzalez; L Meiggs; J I Ten; C Macaya
Journal:  Br J Radiol       Date:  2001-11       Impact factor: 3.039

8.  Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010.

Authors:  Rebecca Smith-Bindman; Diana L Miglioretti; Eric Johnson; Choonsik Lee; Heather Spencer Feigelson; Michael Flynn; Robert T Greenlee; Randell L Kruger; Mark C Hornbrook; Douglas Roblin; Leif I Solberg; Nicholas Vanneman; Sheila Weinmann; Andrew E Williams
Journal:  JAMA       Date:  2012-06-13       Impact factor: 56.272

9.  Radiation exposure during coronary angiography via transradial or transfemoral approaches when performed by experienced operators.

Authors:  Binita Shah; Sripal Bangalore; Frederick Feit; Gregory Fernandez; John Coppola; Michael J Attubato; James Slater
Journal:  Am Heart J       Date:  2013-03       Impact factor: 4.749

Review 10.  Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair.

Authors:  Stephen Balter; John W Hopewell; Donald L Miller; Louis K Wagner; Michael J Zelefsky
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

View more
  4 in total

1.  Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage.

Authors:  Min Ku Chon; Kook Jin Chun; Dae Sung Lee; Soo Yong Lee; Jongmin Hwang; Sang Hyun Lee; Ki Won Hwang; Jeong Su Kim; Young Huyn Park; June Hong Kim
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

2.  Utilization of an Optimized Radiation Strategy in Primary Percutaneous Coronary Intervention for Patients with ST-Segment-Elevation Myocardial Infarction.

Authors:  Xin Zhong; Wei Gao; Dong Huang; Lei Ge; Juying Qian; Junbo Ge
Journal:  Cardiol Res Pract       Date:  2019-09-02       Impact factor: 1.866

3.  Radiation Exposure Reduction and Patient Outcome by Using Very Low Frame Rate Fluoroscopy Protocol (3.8 + 7.5 fps) During Percutaneous Coronary Intervention.

Authors:  Ankush Gupta; Sanya Chhikara; Rajesh Vijayvergiya; Parag Barwad; Krishna Prasad; Rajat Datta; Nalin K Mahesh; Preetika Maurya; Navreet Singh
Journal:  Front Cardiovasc Med       Date:  2021-02-09

4.  Radiation Exposure in Coronary Angiography: A Comparison of Cineangiography and Fluorography.

Authors:  Jongmin Hwang; Soo Yong Lee; Min Ku Chon; Sang Hyun Lee; Ki Won Hwang; Jeong Su Kim; Yong Hyun Park; June Hong Kim; Kook Jin Chun
Journal:  Korean Circ J       Date:  2015-11-25       Impact factor: 3.243

  4 in total