Literature DB >> 24504637

Patient-specific instrumentation does not improve alignment in total knee arthroplasty.

Robert Russell1, Timothy Brown1, Michael Huo1, Richard Jones1.   

Abstract

Patient-specific instrumentation (PSI) was developed to improve the accuracy of component positioning in total knee arthroplasty (TKA). A meta-analysis of level I and level II studies was performed to determine if PSI improves the mechanical alignment of the leg compared with conventional instrumentation (CI) in TKA. Seven studies met inclusion criteria evaluating 559 patients undergoing TKA. Mean coronal alignment was within 1 degree of neutral mechanical alignment in both groups (PSI, 0.78 degrees; CI, 0.81 degrees). There were fewer outliers in the PSI group (21.1%) than in the CI group (23.2%), but this was not statistically significant (p = 0.59). On the basis of the data from this analysis, PSI does not significantly improve the postoperative mechanical alignment of the limb after TKA. Moreover, PSI does not decrease the number of outliers compared with CI. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2014        PMID: 24504637     DOI: 10.1055/s-0034-1368143

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  8 in total

1.  Hand-held navigation may improve accuracy in minimally invasive total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Satit Thiengwittayaporn; Yupadee Fusakul; Nunnapat Kangkano; Chanintorn Jarupongprapa; Narattaphol Charoenphandhu
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

Review 2.  [New technologies (robotics, custom-made) in unicondylar knee arthroplasty-pro].

Authors:  Malin Meier; Tilman Calliess; Carsten Tibesku; Johannes Beckmann
Journal:  Orthopade       Date:  2021-02       Impact factor: 1.087

3.  Accuracy of tibial cuts with patient-specific instrumentation is not influenced by the surgeon's level of experience.

Authors:  Alexander Antoniadis; Roland S Camenzind; Michael O Schär; Dario Bergadano; Näder Helmy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-05       Impact factor: 4.342

Review 4.  [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

Authors:  J Beckmann; A Steinert; C Zilkens; A Zeh; C Schnurr; M Schmitt-Sody; M Gebauer
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

5.  Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.

Authors:  Werner Anderl; Leo Pauzenberger; Roman Kölblinger; Gabriele Kiesselbach; Georg Brandl; Brenda Laky; Bernhard Kriegleder; Philipp Heuberer; Eva Schwameis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-19       Impact factor: 4.342

6.  Postoperative mechanical alignment analysis of total knee replacement patients operated with 3D printed patient specific instruments: A Prospective Cohort Study.

Authors:  Halil Can Gemalmaz; Kerim Sarıyılmaz; Okan Ozkunt; Mustafa Sungur; Ibrahim Kaya; Fatih Dikici
Journal:  Acta Orthop Traumatol Turc       Date:  2019-03-08       Impact factor: 1.511

7.  The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty: A Retrospective Case Series Study.

Authors:  Liang Yuan; Bin Yang; Xiaohua Wang; Bin Sun; Ke Zhang; Yichen Yan; Jie Liu; Jie Yao
Journal:  Biomed Res Int       Date:  2021-02-15       Impact factor: 3.411

Review 8.  A Systematic Literature Review of Three Modalities in Technologically Assisted TKA.

Authors:  William A Leone; Leah C Elson; Christopher R Anderson
Journal:  Adv Orthop       Date:  2015-11-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.